Literature DB >> 29987847

Prospective survey of implantable defibrillator shock anxiety in Japanese patients: Results from the DEF-Chiba study.

Kazuo Miyazawa1, Yusuke Kondo2, Marehiko Ueda1, Takatsugu Kajiyama1, Masahiro Nakano2, Masayuki Inagaki3, Joerg O Schwab4, Samuel F Sears5, Yoshio Kobayashi1.   

Abstract

BACKGROUND: Patient-reported outcomes of implantable cardioverter defibrillator (ICD), such as those with shock anxiety, have emerged as important endpoints that are related to quality of life (QOL), but they have not been well studied in a sample of the Japanese population. Therefore, we prospectively examined changes in shock anxiety in a large sample of Japanese patients with an ICD.
METHODS: We recruited 214 consecutive patients with an ICD who visited the outpatient clinic. At registration and 12 months later, all patients completed the Florida Shock Anxiety Scale (FSAS) questionnaire to allow us to examine changes in shock anxiety over the course of the first year after registration.
RESULTS: During the 12-month follow-up period, 10.5% of the patients received ICD shock therapy. Female sex, secondary prevention, and experience of ICD shock therapy were associated with high FSAS scores at registration. The FSAS scores in both patients with appropriate and inappropriate shock were significantly higher at the 12-month follow-up interval than at registration, and there was no significant difference in the extent of changes in FSAS scores (Δ = 5.2 ± 5.1 and Δ = 6.3 ± 9.9, respectively, P = 0.62).
CONCLUSIONS: Female sex, secondary prevention, and experience of ICD shock therapy are important risk factors affecting shock anxiety in Japanese patients. Attention should be paid to the after-effects of ICD shock in these patients, regardless of the shock type, with particular attention to women and patients who require secondary prevention.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  Florida Shock Anxiety Scale; anxiety; depression; implantable cardioverter defibrillator; implantable cardioverter defibrillator shock

Mesh:

Year:  2018        PMID: 29987847     DOI: 10.1111/pace.13442

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Prognostic impact of recurrences of ventricular tachyarrhythmias and appropriate ICD therapies in a high-risk ICD population.

Authors:  Tobias Schupp; Ibrahim Akin; Linda Reiser; Armin Bollow; Gabriel Taton; Thomas Reichelt; Dominik Ellguth; Niko Engelke; Uzair Ansari; Kambis Mashayekhi; Christel Weiß; Christoph Nienaber; Muharrem Akin; Martin Borggrefe; Michael Behnes
Journal:  Clin Res Cardiol       Date:  2019-02-12       Impact factor: 5.460

2.  An Evaluation of the Association between Quality of Life and Psychological Issues in Patients with Automated Implantable Cardioverter Defibrillator.

Authors:  Nilofar Pasyar; Masoume Rambod; Mohammad Hossein Nikoo; Parisa Mansouri
Journal:  J Caring Sci       Date:  2021-11-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.