| Literature DB >> 29970169 |
Hirut Tadesse1, Kassu Desta2, Samuel Kinde2, Fatuma Hassen2, Addisu Gize3.
Abstract
OBJECTIVE: The objective of this study was to determine the magnitude of pre-analytical, analytical and post-analytical laboratory errors in hematology tests.Entities:
Keywords: Hematological errors; Laboratory errors; Pre-analytical errors in hematology
Mesh:
Year: 2018 PMID: 29970169 PMCID: PMC6029268 DOI: 10.1186/s13104-018-3551-y
Source DB: PubMed Journal: BMC Res Notes ISSN: 1756-0500
Characteristics of the laboratory request forms submitted to the hematology laboratory and errors at St. Paul’s Hospital Millennium Medical College, Addis Ababa, Ethiopia
| Documented items | Well written items (%) | Number of errors (%) |
|---|---|---|
| Patient ID number | 2606 (100) | 0 (0) |
| Patient name | 2600 (99.8) | 6 (0.2) |
| Ward/clinic name | 2587 (99.3) | 19 (0.7) |
| Request type | 2515 (96.5) | 91 (3.5) |
| Date of request | 2440 (93.6) | 166 (6.4) |
| Gender | 2340 (89.7) | 266 (10.3) |
| Age of patient | 2308 (88.5) | 298 (11.5) |
| Physician name | 391 (15) | 2215 (85) |
| Physician signature | 1764 (67.7) | 842 (32.3) |
| Clinical detail | 779 (29.9) | 1827 (70.1) |
N = 560
Types of pre-analytical hematology laboratory errors from different departments in SPHMMC, Addis Ababa, Ethiopia
| Categories | Requests | Emergency | Inpatient | Outpatient | Private wing | No location |
|---|---|---|---|---|---|---|
| Total | 2606 | 386 (15) | 529 (20.3) | 1509 (58) | 163 (6.3) | 19 (0.73) |
| Pre-analytical | 560 (21.5) | 91 (23.6) | 123 (23.3) | 311 (20.7) | 28 (17.2) | 7 (35) |
| Hemolysis | 193 (34.5) | 10 (11) | 59 (48) | 122 (39.2) | 1 (3.6) | 1 (14.3) |
| Clotted | 13 (2.3) | 5 (5.5) | 5 (4.1) | 1 (0.3) | 2 (7.1) | 0 (0.0) |
| Mislabeled | 32 (5.7) | 28 (30.8) | 1 (0.8) | 1 (0.32) | 2 (7.1) | 0 (0.0) |
| Over sample | 45 (8.0) | 8 (8.8) | 20 (16.3) | 15 (4.8) | 2 (7.1) | 0 (0.0) |
| Inadequate sample | 274 (48.9) | 30 (32.9) | 51 (41.4) | 171 (56.3) | 19 (67.9) | 3 (42.9) |
| Delayed sample | 3 (0.5) | 2 (2.2) | 1 (0.8) | 0 (0.0) | 0 (0.0) | 0 (0.0) |
The frequency of analytical and post-analytical errors (N = 182) in hematology laboratory at SPHMMC, Addis Ababa, Ethiopia
| Analytical errors | N (%) | Post-analytical errors | N (%) |
|---|---|---|---|
| Wrong reagent storage tem | 6 (42.8) | Communication errors | 126 (75) |
| Electric interruption | 5 (35.7) | Delayed results | 7 (4.1) |
| Expired reagents | 2 (14.2) | Transcription errors | 25 (14.8) |
| Non conformity with QC | 1 (7.1) | Data entry errors | 9 (5.4) |
| Total | 14 (100) | Lost results | 1 (0.6) |
| Total | 168 (100) |