Ji Won Lee1, Hyae Young Kim2, Jin Mo Goo3, Eun Young Kim4, Soo Jung Lee5, Tae Jung Kim6, Yeol Kim7, Juntae Lim7.
Abstract
Objective: To report the radiological results of a pilot study for the Korean Lung Cancer Screening project conducted to evaluate the feasibility of lung cancer screening using low-dose chest computed tomography (LDCT) in Korea. Materials andEntities:
Keywords: Computed tomography; Low dose; Lung cancer; Lung-RADS; Screening
Mesh:
Year: 2018 PMID: 29962887 PMCID: PMC6005960 DOI: 10.3348/kjr.2018.19.4.803
Source DB: PubMed Journal: Korean J Radiol ISSN: 1229-6929 Impact factor: 3.500
Inclusion and Exclusion Criteria for Our Pilot Study for K-LUCAS Project
| Inclusion Criteria | Exclusion Criteria |
|---|---|
| Age of 55–74 years | Past history of lung cancer |
| Asymptomatic current or ex-smoker | ECOG score of ≥ 2 |
| Smoking history of at least 30 pack-years and tobacco use within last 15 years | Treatment for pulmonary tuberculosis, pneumonia, or interstitial lung disease |
| Diagnosis of other cancers* within 5 years before enrollment | |
| Chest CT performed within 6 months before enrollment |
*All cancers excluding thyroid cancer and skin cancer. CT = computed tomography, ECOG = Eastern Cooperative Oncology Group, K-LUCAS = Korean Lung Cancer Screening
LDCT Scanners and Scanning Parameters Used in Our Pilot Study for K-LUCAS Project
| Total (n = 256) | GE Discovery 750 (n = 32) | GE Revolution (n = 9) | Somatom Definition (n = 101) | Somatom Definition Flash (n = 22) | Brilliance 64 (n = 92) |
|---|---|---|---|---|---|
| Scanning parameters | |||||
| Scan mode | Spiral | Spiral | Spiral | Spiral | Spiral |
| Rotation time (s) | 0.5 | 0.5 | 0.33 | 0.28 | 0.5 |
| Collimation (mm) | 0.625 × 64 | 0.625 × 64 | 0.6 × 32 × 2 | 0.6 × 64 × 2 | 0.625 × 64 |
| Pitch | 0.984 | 0.984 | 1 | 1 | 1 |
| kVp | 120 (n = 3) | 100 | 120 | 120 | 120 |
| 100 (n = 29) | |||||
| mAs | 50 | 30 | 30 (n = 1) | 25 (n = 18) | |
| 50 (n = 4) | |||||
| Reference mAs | 25 (n = 100) | 26 | |||
| Reconstruction | |||||
| Slice thickness/interval (mm) | 1.25/1.25 for axial images | 1.25/1.25 for axial images | 1/1 for axial images | 1/1 for axial images | 1/1 for axial images |
| 2.5/2.5 for axial and coronal images | 2.5/2.5 for axial and coronal images | 3/3 for axial and coronal images | 2.5/2.5 for axial images | ||
| Reconstruction algorithm | Lung for 1.25-mm images | Lung for 1.25-mm images | B50 for 1-mm images | I70f for 1-mm images | YA for 1-mm images |
| Standard for 2.5-mm images | Standard for 2.5-mm images | B31 for 3-mm images | I50f for 3-mm images | A for 2.5-mm images | |
| Iterative reconstruction | ASIR 50 | ASIR-V 50 | SAFIRE level 2 | SAFIRE level 1 |
ASIR = adaptive statistical iterative reconstruction, LDCT = low-dose chest computed tomography, SAFIRE = Sinogram Affirmed Iterative Reconstruction
Baseline Characteristics of Participants in Our Pilot Study for K-LUCAS Project
| Baseline Characteristics | Values |
|---|---|
| Age (years) | 63.2 ± 5.4 |
| Men (%) | 253 (98.8) |
| Height (cm)* | 168.2 ± 6.2 |
| Weight (kg)* | 69.2 ± 9.7 |
| BMI (kg/m2)* | 24.4 ± 3.0 |
| Smoking status (%) | |
| Current | 138 (53.9) |
| Former | 118 (46.1) |
| Pack-years | 40.0 ± 21.9 |
| Current | 39.7 ± 9.2 |
| Ex-smoker | 40.4 ± 30.8 |
Values are expressed as means ± standard deviations or numbers (%). *Height, weight, and BMI data were missing for three participants. BMI = body mass index
Distribution of Nodules Detected on LDCT Screening in Our Pilot Study for K-LUCAS Project
| Characteristics | Values, n (%) |
|---|---|
| No nodule | 126 (49.2) |
| Any noncalcified nodule | 121 (47.3) |
| Any noncalcified nodule ≥ 4 mm | 74 (28.9) |
| Solid nodules only | 65 (87.8) |
| Subsolid nodules only | 5 (6.8) |
| Both solid and subsolid nodules | 4 (5.4) |
American College of Radiology Lung-RADS Categories Based on Initial Findings of LDCT in Our Pilot Study for K-LUCAS Project
| Lung-RADS Category | Values, n (%) |
|---|---|
| 1 | 146 (57.1) |
| 2 | 91 (35.5) |
| 3 | 10 (3.9) |
| 4 | 9 (3.5) |
| A | 8 |
| B | 1 |
| X | 0 |
| Lung-RADS screening results | |
| Negative (category 1 and 2) | 237 (92.6) |
| Positive (category 3 and 4) | 19 (7.4) |
Lung-RADS = Lung Imaging Reporting and Data System
Radiation Dose Used for LDCT in Our Pilot Study for K-LUCAS Project
| Radiation Dose | Values |
|---|---|
| Mean volume CT dose index (mGy)* | 1.7 ± 0.6 |
| Dose-length product (mGy-cm)* | 68.7 ± 21.8 |
| Effective radiation dose (mSv)* | 1.0 ± 0.3 |
Values are expressed as means ± standard deviations. *Radiation dose parameters were missing for three patients.