The accuracy of virtual interocclusal registration during intraoral scanning.

Faraj Edher1, Alan G Hannam2, David L Tobias3, Chris C L Wyatt4.   

Abstract

STATEMENT OF PROBLEM: Evidence on the accuracy and reproducibility of the virtual interocclusal registration procedure and recommendations as to how to make a virtual interocclusal record are lacking.
PURPOSE: The purpose of this in vitro study was to assess whether virtual interocclusal registration records made at different locations around the arch affect the alignment of virtual casts, and to assess whether quadrant and complete arch scans have different effects on cast alignment when they are articulated with virtual interocclusal records.
MATERIAL AND METHODS: Three sites of close proximity (SCPs) and 3 sites of clearance (SCs) were identified in each sextant of mounted zirconia master models. The SCPs and SCs were confirmed by using shimstock foil and the transillumination of an interocclusal impression. Complete-arch and quadrant scans of the master models were made with an intraoral scanner and registered with different virtual interocclusal registration records. The SCPs and SCs indicated by the scanner's software and by independent software were compared according to the sensitivity, specificity, and predictive values of each method.
RESULTS: Changed locations of SCPs were found depending on the location of the virtual interocclusal registration record. The intraoral scanner's software contacts had a higher sensitivity of 92.86% and a negative predictive value of 84.21% than the contacts revealed by the independent software that exhibited a sensitivity of 69.05% and a negative predictive value of 70.45%. However, the intraoral scanner software had a lower specificity of 41.03% and a positive predictive value of 62.90% compared with the independent software, which exhibited a specificity of 79.49% and a positive predictive value of 78.38%. The quadrant scans had a higher sensitivity than did the complete-arch scans.
CONCLUSIONS: Different occlusal contacts are obtained from interocclusal registration scans in different segments of the dental arch. The difference is more obvious in complete-arch scans, where a tilting effect toward the site of the interocclusal registration scan was observed. Occlusal contacts obtained from interocclusal registration scans for quadrant scans had a higher sensitivity than did those for complete-arch scans.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2018        PMID: 29961618     DOI: 10.1016/j.prosdent.2018.01.024

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Precision of the virtual occlusal record.

Authors:  Keyan P Botsford; Michael C Frazier; Ahmed A M Ghoneima; Achint Utreja; Surya S Bhamidipalli; Kelton T Stewart
Journal:  Angle Orthod       Date:  2019-03-28       Impact factor: 2.079

2.  Reliability and Time Efficiency of Digital vs. Analog Bite Registration Technique for the Manufacture of Full-Arch Fixed Implant Prostheses.

Authors:  Philippe Nuytens; Rani D'haese; Stefan Vandeweghe
Journal:  J Clin Med       Date:  2022-05-19       Impact factor: 4.964

3.  An In-Vitro Evaluation of Articulation Accuracy for Digitally Milled Models vs. Conventional Gypsum Casts.

Authors:  Jason D Lee; German O Gallucci; Sang J Lee
Journal:  Dent J (Basel)       Date:  2022-01-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.