B Laxmi Narayana1, Pooja Rao1, Sevitha Bhat1, K Vidyalakshmi1.
Abstract
Soft contact lenses provide perfect conditions for the breeding of pathogens. The study is a prospective, experimental study, conducted to know the antimicrobial ability of multipurpose contact lens solution against standard strains of Staphylococcus aureus and Pseudomonas aeruginosa by the stand-alone test. The test method is based on the procedures in the ISO 14729 standard primary stand-alone test. Three multipurpose contact lens care solutions commercially available in Mangalore markets, namely, Biotrue (Bausch & Lomb), Opti-Free Replenish (Alcon), and Aquasoft (Stericon Pharma), were tested for its antimicrobial effect in the microbiology lab at Kasturba Medical College, Mangalore. According to this study, the solutions named "Biotrue" and "Aquasoft" met the primary stand-alone and reached the 3log reduction and 5log reduction criteria in the manufacturer recommended time, respectively. No conclusion could be drawn for Opti-Free Replenish since the minimum recommended disinfection time was overnight, whereas it was noted for 6 hr only, and it should have been experimented further. The effectiveness of multipurpose solutions varies against different bacterial species. We have observed that the antimicrobial activity of different solutions varies with respect to time of incubation, and also there was a marked difference in the activity of some solutions against S. aureus and P. aeruginosa. So, it is necessary for the contact lens users to store their lenses in solutions for longer duration of hours. It is also recommended to use solutions that clear the ISO 14729 standards for better health conditions of the eye.Entities:
Year: 2018 PMID: 29955230 PMCID: PMC6000856 DOI: 10.1155/2018/5916712
Source DB: PubMed Journal: Int J Microbiol
Colony counts per solution per time interval for Staphylococcus aureus.
| Time | Biotrue | Aquasoft | Opti-Free Replenish | Control: saline |
|---|---|---|---|---|
| Zero | 100,000 | 100,000 | 100,000 | 100,000 |
| 10 minutes | 33,400 | 12,000 | 37,200 | 100,000 |
| 30 minutes | 9500 | 8800 | 11,600 | 100,000 |
| Two hours | 0 | 6200 | 2800 | 100,000 |
| Four hours | 0 | 0 | 2200 | 100,000 |
| Six hours | 0 | 0 | 1800 | 100,000 |
Colony counts per solution per time interval for Pseudomonas aeruginosa.
| Time | Biotrue | Aquasoft | Opti-Free Replenish | Control: saline |
|---|---|---|---|---|
| Zero | 100,000 | 100,000 | 100,000 | 100,000 |
| 10 minutes | 10,300 | 7000 | 10,000 | 100,000 |
| 30 minutes | 1500 | 6400 | 8200 | 100,000 |
| Two hours | 400 | 1700 | 7800 | 100,000 |
| Four hours | 0 | 1100 | 6000 | 100,000 |
| Six hours | 0 | 0 | 5552 | 100,000 |
Log reduction per solution per time interval for Staphylococcus aureus.
| Time | Biotrue | Aquasoft | Opti-Free Replenish |
|---|---|---|---|
| 10 minutes | 0.48 | 0.93 | 0.43 |
| 30 minutes | 1.02 | 1.06 | 0.94 |
| Two hours | 5 | 1.21 | 1.56 |
| Four hours | 5 | 5 | 1.66 |
| Six hours | 5 | 5 | 1.75 |
Log reduction per solution per time interval for Pseudomonas aeruginosa.
| Time | Biotrue | Aquasoft | Opti-Free Replenish |
|---|---|---|---|
| 10 minutes | 0.99 | 1.16 | 1 |
| 30 minutes | 1.83 | 1.21 | 1.09 |
| Two hours | 2.40 | 1.77 | 1.11 |
| Four hours | 5 | 1.96 | 1.23 |
| Six hours | 5 | 5 | 1.26 |
Figure 1Effects of different MPS and length of exposure on the concentration of Staphylococcus aureus.
Figure 2Effects of different MPS and length of exposure on the concentration of Pseudomonas aeruginosa.