Literature DB >> 2995439

Fluoroimmunoassay for detection of rubella-specific immunoglobulin M: comparison with indirect enzyme immunoassay and mu-chain capture.

J M Echevarria, F de Ory, R Najera.   

Abstract

The performance of a commercially-available method of fluoroimmunoassay (Rubella M FIAX, International Diagnostic Technology, Santa Clara, Calif.), designed for the detection of rubella-specific immunoglobulin M, was tested with 137 selected sera, including 52 from cases of primary rubella, 29 from healthy pregnant women, 21 containing rheumatoid factor, and 35 from cases of infectious mononucleosis (IM) caused by Epstein-Barr virus. The results were compared with those obtained by commercial indirect enzyme immunoassay (EIA) and EIA anti-mu chain capture tests. The fluoroimmunoassay technique showed a satisfactory level of sensitivity, but low values had to be interpreted with caution as false-positive results were detected with sera with rheumatoid factor and from IM cases, even after preliminary treatment of sera with the anti-human immunoglobulin G antisera provided in the kit. On the other hand, no false-positive results in the analysis of IM sera were seen in the EIA anti-mu chain capture method. Because of its sensitivity and specificity, we recommend the use of the latter technique for the diagnosis of primary rubella.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 2995439      PMCID: PMC268426          DOI: 10.1128/jcm.22.3.428-434.1985

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  9 in total

1.  Immunofluorescence in cells derived from Burkitt's lymphoma.

Authors:  G Henle; W Henle
Journal:  J Bacteriol       Date:  1966-03       Impact factor: 3.490

2.  Evaluation and comparison of two assays for detection of immunity to rubella infection.

Authors:  J P Brody; J H Binkley; S A Harding
Journal:  J Clin Microbiol       Date:  1979-11       Impact factor: 5.948

Review 3.  Detection of antiviral IgM antibodies and its problems--a review.

Authors:  O Meurman
Journal:  Curr Top Microbiol Immunol       Date:  1983       Impact factor: 4.291

4.  A comparison of Rubazyme-M and MACRIA for the detection of rubella-specific IgM.

Authors:  J M Best; S J Palmer; P Morgan-Capner; J Hodgson
Journal:  J Virol Methods       Date:  1984-02       Impact factor: 2.014

5.  Detection of rubella antibodies by hemagglutination inhibition, indirect fluorescent-antibody test, and enzyme-linked immunosorbent assay.

Authors:  M V Zartarian; G Friedly; E M Peterson; L M de la Maza
Journal:  J Clin Microbiol       Date:  1981-12       Impact factor: 5.948

6.  Evaluation of commercially available diagnostic test kits for rubella.

Authors:  G A Castellano; D L Madden; G T Hazzard; C S Cleghorn; D V Vails; A C Ley; N R Tzan; J L Sever
Journal:  J Infect Dis       Date:  1981-04       Impact factor: 5.226

7.  Rubella antibodies detected by several commercial immunoassays in hemagglutination inhibition-negative sera.

Authors:  K T Kleeman; D J Kiefer; S P Halbert
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

8.  Comparison of several test systems used for determination of rubella immune status.

Authors:  A S Weissfeld; W D Gehle; A C Sonnenwirth
Journal:  J Clin Microbiol       Date:  1982-07       Impact factor: 5.948

9.  Antibody capture radioimmunoassay for anti-rubella IgM.

Authors:  P P Mortimer; R S Tedder; M H Hamblig; M S Shafi; F Burkhardt; U Schilt
Journal:  J Hyg (Lond)       Date:  1981-04
  9 in total
  3 in total

1.  Detection of immunoglobulins G and M to rubella virus by time-resolved immunofluorometry.

Authors:  P Shankaran; E Reichstein; M J Khosravi; E P Diamandis
Journal:  J Clin Microbiol       Date:  1990-03       Impact factor: 5.948

2.  Multicenter evaluation of a new commercial assay for detection of immunoglobulin M antibodies to Toxoplasma gondii. Multicenter Study Group.

Authors:  V Luyasu; A R Robert; L Schaefer; J Macioszek
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1995-09       Impact factor: 3.267

3.  Evaluation of microparticle enzyme immunoassays for immunoglobulins G and M to rubella virus and Toxoplasma gondii on the Abbott IMx automated analyzer.

Authors:  L E Schaefer; J W Dyke; F D Meglio; P R Murray; W Crafts; A C Niles
Journal:  J Clin Microbiol       Date:  1989-11       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.