Literature DB >> 29942403

Survey Result of the Counting Efficiency of Gamma Counter by Certified Reference Materials.

Ji-In Bang1, Ho-Young Lee1, Geyoung Woon Noh2, Jeong Mi Park3, June Kee Yoon4.   

Abstract

PURPOSE: In radioimmunoassay (RIA), the gamma counter is the important instrument for the accurate measurement. To manage quality assurance of RIA, the counting efficiency of gamma counter is one of the important parameters. The aim of this study was to evaluate the counting efficiency of gamma counters in multiple institutes on the base of traceability by using the certified reference materials (CRMs).
METHODS: Twenty-three institutes that perform RIA were enrolled in this study. I-125 CRMs that were certified by National Institute of Standards and Technology (NIST) were used. Each institute was asked to count the activity of I-125 CRMs at most twice on all gamma counters in use. The counting efficiency of each well of counter was calculated on the base of NIST-certified information, corrected for I-125 decay for date of testing.
RESULTS: From 23 institutes, 44 gamma counters were evaluated. The average counting efficiency of all wells was 85.9% and the standard deviation was 13.5%. As a mean value of each gamma counter, three gamma counters showed poor counting efficiency (less than 70%). The poorest counting efficiency was 7%. The counting efficiency of seven gamma counters was between 70 and 75%. Eight counters had the counting efficiency between 75 and 90%. More than half of counter (26 gamma counters) showed excellent counting efficiency (more than 90%). The standard deviation variation range of inter-well efficiency was from 0 to 11.2.
CONCLUSION: The first survey on the counting efficiency of gamma counter was performed in South Korea. Most of the RIA laboratories have well managed the quality assurance of gamma counter.

Entities:  

Keywords:  Efficiency; Immunoradiometric assay; Quality control; Radioimmunoassay

Year:  2018        PMID: 29942403      PMCID: PMC5995781          DOI: 10.1007/s13139-018-0515-z

Source DB:  PubMed          Journal:  Nucl Med Mol Imaging        ISSN: 1869-3474


  5 in total

1.  Immunoassay of endogenous plasma insulin in man.

Authors:  R S YALOW; S A BERSON
Journal:  J Clin Invest       Date:  1960-07       Impact factor: 14.808

2.  Random Assay in Radioimmunoassay: Feasibility and Application Compared with Batch Assay.

Authors:  Jung Min Lee; Hwan Hee Lee; Sohyun Park; Tae Sung Kim; Seok-Ki Kim
Journal:  Nucl Med Mol Imaging       Date:  2016-07-26

3.  Radioimmunoassay: principle and technique.

Authors:  P Zaidi; S Kamal
Journal:  J Pak Med Assoc       Date:  1993-12       Impact factor: 0.781

4.  Variation in gamma counter efficiency used in radioimmunoassay testing for hepatitis B surface antigen and antibody.

Authors:  Z B Bales; J F Patterson; J H Hoofnagle; L B Seeff
Journal:  Transfusion       Date:  1978 Jan-Feb       Impact factor: 3.157

5.  Performance assessment of a NaI(Tl) gamma counter for PET applications with methods for improved quantitative accuracy and greater standardization.

Authors:  Martin A Lodge; Daniel P Holt; Paul E Kinahan; Dean F Wong; Richard L Wahl
Journal:  EJNMMI Phys       Date:  2015-05
  5 in total