Literature DB >> 29933883

Current State of Image Guidance in Radiation Oncology: Implications for PTV Margin Expansion and Adaptive Therapy.

Wei Zou1, Lei Dong2, Boon-Keng Kevin Teo2.   

Abstract

Image guidance technology has evolved and seen widespread application in the past several decades. Advancements in the diagnostic imaging field have found new applications in radiation oncology and promoted the development of therapeutic devices with advanced imaging capabilities. A recent example is the development of linear accelerators that offer magnetic resonance imaging for real-time imaging and online adaptive planning. Volumetric imaging, in particular, offers more precise localization of soft tissue targets and critical organs which reduces setup uncertainty and permit the use of smaller setup margins. We present a review of the status of current imaging modalities available for radiation oncology and its impact on target margins and use for adaptive therapy.
Copyright © 2018 Elsevier Inc. All rights reserved.

Mesh:

Year:  2018        PMID: 29933883     DOI: 10.1016/j.semradonc.2018.02.008

Source DB:  PubMed          Journal:  Semin Radiat Oncol        ISSN: 1053-4296            Impact factor:   5.934


  6 in total

Review 1.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

2.  A Probability-Based Investigation on the Setup Robustness of Pencil-beam Proton Radiation Therapy for Skull-Base Meningioma.

Authors:  Wei Zou; Goldie Kurtz; Mayisha Nakib; Brendan Burgdorf; Murat Alp; Taoran Li; Robert Lustig; Ying Xiao; Lei Dong; Alireza Kassaee; Michelle Alonso-Basanta
Journal:  Int J Part Ther       Date:  2021-01-28

3.  Estimation of planning organ at risk volumes for ocular structures in dogs undergoing three-dimensional image-guided periocular radiotherapy with rigid bite block immobilization.

Authors:  Friederike Wolf; Carla Rohrer Bley; Jürgen Besserer; Valeria Meier
Journal:  Vet Radiol Ultrasound       Date:  2021-01-18       Impact factor: 1.363

4.  Gadoxetic Acid Uptake Rate as a Measure of Global and Regional Liver Function as Compared With Indocyanine Green Retention, Albumin-Bilirubin Score, and Portal Venous Perfusion.

Authors:  Josiah Simeth; Madhava Aryal; Dawn Owen; Kyle Cuneo; Theodore S Lawrence; Yue Cao
Journal:  Adv Radiat Oncol       Date:  2022-03-16

5.  Improved Ipsilateral Breast and Chest Wall Sparing With MR-Guided 3-fraction Accelerated Partial Breast Irradiation: A Dosimetric Study Comparing MR-Linac and CT-Linac Plans.

Authors:  Hima Bindu Musunuru; Poonam Yadav; Stephanie J Olson; Bethany M Anderson
Journal:  Adv Radiat Oncol       Date:  2021-01-22

Review 6.  Medical physics challenges in clinical MR-guided radiotherapy.

Authors:  Christopher Kurz; Giulia Buizza; Guillaume Landry; Florian Kamp; Moritz Rabe; Chiara Paganelli; Guido Baroni; Michael Reiner; Paul J Keall; Cornelis A T van den Berg; Marco Riboldi
Journal:  Radiat Oncol       Date:  2020-05-05       Impact factor: 3.481

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.