Literature DB >> 29926977

Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study.

Bahaa Alshawaf1, Hans-Peter Weber1, Matthew Finkelman2, Khaled El Rafie1, Yukio Kudara1, Panos Papaspyridakos1.   

Abstract

OBJECTIVES: The aim of this in vitro study was to compare the accuracy of printed implant casts from digital impressions with two intra-oral scanners (IOS) to stone casts from conventional impressions. The hypothesis was that printed casts would be more accurate than stone casts from conventional impressions.
MATERIALS AND METHODS: A mandibular stone cast with Kennedy class II edentulism was fabricated using two internal connection tissue-level implants at 30 degrees to each other (Replace Select RP, Nobel Biocare) to serve as master. Digital impressions (n = 10) were made with the white light (WL) and Active Wavefront Sampling technology (AWST) IOS. The resultant standard tessellation language (STL) datasets were used to print implant casts through stereolithography (SLA) prototyping. The conventional casts (n = 10) were produced with splinted open tray impression technique and polyether material in type IV stone. The master cast and all groups were digitized with lab reference scanner. The test groups STL datasets were superimposed to master cast STL in inspection software (Geomagic control 2015) to calculate root-mean-square error.
RESULTS: The conventional, WL IOS and AWST IOS groups had mean values of 53.49 μm (SD 9.47), 108.09 μm (SD 9.59) and 120.39 μm (SD 5.91), respectively. The Shapiro-Wilk test showed no evidence of nonnormality (p = 0.131) and Levene's test showed no evidence of heterogeneity of variance (p = 0.518). The one-way ANOVA demonstrated a statistically significant difference (p < 0.001). Tukey's honest significant difference (HSD) showed statistically significant differences between all groups: for the comparison of AWST IOS and WL IOS, the p-value was 0.009, and the p-values of the other post hoc tests were <0.001.
CONCLUSION: Printed casts generated from digital impressions for partially edentulous posterior mandibular arches had inferior accuracy to conventional stone casts fabricated from splinted open tray impressions. The printed casts from WL IOS had better accuracy compared to AWST IOS.
© 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; digital dentistry; digital implant impressions; implant impressions; partial edentulous; printed casts; stone casts

Mesh:

Substances:

Year:  2018        PMID: 29926977     DOI: 10.1111/clr.13297

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

1.  Assessment of different types of intra oral scanners and 3D printers on the accuracy of printed models: An in vitro study.

Authors:  Fernando Igai; Washington-Steagall Junior; Carolina-Mayumi Iegami; Pedro-Tortamano Neto
Journal:  J Clin Exp Dent       Date:  2021-12-01

Review 2.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

3.  Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study.

Authors:  Bowen Ma; Xinxin Yue; Yujie Sun; Lingyan Peng; Wei Geng
Journal:  BMC Oral Health       Date:  2021-12-10       Impact factor: 2.757

4.  Application of a new scan body for face-driven fixed prosthetics.

Authors:  Naruto Otawa; Tsukasa Aoki; Tomoki Sumida; Tsukasa Yanagi; Hirofumi Kido
Journal:  Clin Exp Dent Res       Date:  2021-08-25

5.  Effect of Different CAD/CAM Milling and 3D Printing Digital Fabrication Techniques on the Accuracy of PMMA Working Models and Vertical Marginal Fit of PMMA Provisional Dental Prosthesis: An In Vitro Study.

Authors:  Marina Sidhom; Hanaa Zaghloul; Ihab El-Sayed Mosleh; Elzahraa Eldwakhly
Journal:  Polymers (Basel)       Date:  2022-03-22       Impact factor: 4.329

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.