Alexey Surov1, Paola Clauser2, Yun-Woo Chang3, Lihua Li4, Laura Martincich5, Savannah C Partridge6, Jin You Kim7, Hans Jonas Meyer8, Andreas Wienke9.
Abstract
BACKGROUND: Numerous studies have analyzed associations between apparent diffusion coefficient (ADC) and histopathological features such as Ki-67 proliferation index in breast cancer (BC), with mixed results. The purpose of this study was to perform a multicenter analysis to determine relationships between ADC and expression of Ki-67 and tumor grade in BC.Entities:
Keywords: ADC; Breast cancer; DWI; Ki-67
Mesh:
Substances:
Year: 2018 PMID: 29921323 PMCID: PMC6011203 DOI: 10.1186/s13058-018-0991-1
Source DB: PubMed Journal: Breast Cancer Res ISSN: 1465-5411 Impact factor: 6.466
Analyzed tumors
| Diagnosis | No. | % |
|---|---|---|
| DCIS | 45 | 5.17 |
| IDC | 713 | 81.95 |
| ILC | 57 | 6.55 |
| Combined IDC/ILC | 9 | 1.03 |
| Mucinous carcinoma | 7 | 0.81 |
| Tubular carcinoma | 3 | 0.35 |
| Metaplastic carcinoma | 2 | 0.23 |
| Unspecified | 34 | 3.91 |
| Total | 870 | 100 |
Abbreviations: DCIS Ductal carcinoma in situ, IDC Invasive ductal carcinoma. ILC Invasive lobular carcinoma
Patients and magnetic resonance imaging techniques
| Centers | No. of patients | MRI equipment and field strength | DWI sequences and b-values |
|---|---|---|---|
| 1 | 115 | 1.5-T scanner (MAGNETOM Avanto; Siemens Medical Systems, Erlangen, Germany) | Single-shot echo-planar sequence (TR/TE: 7100/84 ms); b-values: 0–1000 s/mm2 |
| 2 | 335 | 1.5-T scanner (Sonata; Siemens Medical Systems, Erlangen, Germany) | Single-shot echo-planar sequence (TR/TE: 5000/110 ms); b-values: 0–1000 s/mm2 |
| 3 | 82 | 3.0-T scanner (MAGNETOM Verio, Siemens Medical Systems, Erlangen, Germany) | Single-shot echo-planar sequence (TR/TE: 7000/85 ms); b-values: 50–1000 s/mm2 |
| 4 | 143 | 1.5-T scanner (GE Healthcare Life Sciences, Milwaukee, WI, USA) | Single-shot echo-planar sequence (TR/TE: 7000/85 ms); b-values: 0–900 s/mm2 |
| 5 | 107 | 3-T scanner (Achieva TX; Philips Healthcare, Best, The Netherlands) | Single-shot echo-planar sequence (TR/TE: 5336/ 61 ms); b-values: 0–800 s/mm2 |
| 6 | 88 | 3-T scanner (Trio Tim; Siemens Medical Systems, Erlangen, Germany) | Single-shot echo-planar sequence (TR/TE: 6600/91 ms); b-values: 0–1000 s/mm2 |
Abbreviations: MRI Magnetic resonance imaging, DWI Diffusion-weighted imaging, TR Repetition time, TE Echo time
Fig. 1Comparison of apparent diffusion coefficient (ADC) values between ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC) and invasive lobular carcinoma (ILC)
Fig. 2Comparison of apparent diffusion coefficient (ADC) values between grades 1, 2, and 3 tumors
Fig. 3ROC curve for use of apparent diffusion coefficient (ADC) values in distinguishing grades 2 and 3 breast cancer from grade 1 tumors. Threshold ADC value = 1.03, sensitivity = 56.2%, specificity = 67.9%, positive predictive value = 18.2%, and negative predictive value = 92.4%
Fig. 4Correlation between apparent diffusion coefficient (ADC) and expression of Ki-67. The calculated correlation coefficient was − 0.202 (P< 0.001)
Fig. 5Comparison of apparent diffusion coefficient (ADC) values between tumors with low expression of Ki-67 (< 25%) and high expression of Ki-67 (≥ 25%)
Fig. 6ROC curve for use of apparent diffusion coefficient (ADC) values in discrimination between tumors with low Ki-67 expression (< 25%) and high Ki-67 expression (≥ 25%). The threshold ADC value was 0.91. Sensitivity = 64.4%, specificity = 50.0%
Results of ROC analysis
| Ki-67 expression threshold | ADC threshold | Sensitivity | Specificity | AUC | Positive predictive value | Negative predictive value |
|---|---|---|---|---|---|---|
| ≥ 10% | 0.951 | 0.704 | 0.542 | 0.644 | 0.267 | 0.885 |
| ≥ 20% | 0.913 | 0.700 | 0.494 | 0.613 | 0.498 | 0.696 |
| ≥ 30% | 0.913 | 0.639 | 0.512 | 0.590 | 0.712 | 0.430 |
| ≥ 40% | 0.821 | 0.808 | 0.366 | 0.576 | 0.844 | 0.311 |
| ≥ 50% | 0.821 | 0.807 | 0.413 | 0.600 | 0.892 | 0.263 |
ADC Apparent diffusion coefficient