OBJECTIVE: The primary objective of this study was to examine the association between body mass index (BMI) and the depth of tissue overlying the epidural space. Secondary objectives examined the association between BMI and (1) radiation dose exposure and (2) fluoroscopic screening time during transforaminal nerve block (TFNB) injections.
METHODOLOGY: This is a retrospective cohort study including patients aged ≥ 16 years who underwent unilateral single-level TFNB in a single centre over a 28-month period, by a single spinal orthopaedic surgeon. Demographic data, BMI (kg/m2), fluoroscopic screening time (seconds) and radiation dose exposure (centi-gray per square centimetre squared (cGy-cm2)) were recorded. Exposure of interest: BMI. PRIMARY OUTCOME: depth of epidural space. SECONDARY OUTCOMES: (1) radiation dose exposure, (2) fluoroscopic screening time. Descriptive statistics for study participants' demographics are presented. Spearman's rank (r) coefficient and linear regression analysis was performed examining the association between BMI and the outcome measures.
RESULTS: A total of 362 patients met inclusion criteria; n = 45 patients were excluded due to incomplete data, final analysis included 317 patients. Mean age was 62.6 years (IQR 53-74). Male:female ratio was 37.9% (n = 120):62.1%(n = 197). Mean BMI was 26.9 kg/m2 (IQR 24.4-28.9 kg/m2). Following adjustment for age, gender and spinal comorbidities there is a statistically significant association between BMI and the depth of tissue overlying the epidural space (adjusted coefficient 2.41, (95% CI (2.14, 2.68), p < 0.001)). We also found a significant association between BMI and both secondary outcomes, radiation dose exposure (adjusted coefficient 1.45, (95% CI (0.84, 2.06), p < 0.001)) and fluoroscopic screening time (adjusted coefficient 0.11, (95% CI (0.02, 0.20), p = 0.02)).
CONCLUSION: This study has demonstrated a significant association between increasing BMI and increased depth of the epidural space. Furthermore, significant associations between increasing BMI, radiation dose exposure and fluoroscopy screening time have been identified. BMI may represent a modifiable risk factor with a view to decreasing patient exposure to medical ionised radiation.

Entities:  

Keywords:  Body mass index; Epidural space depth; Fluoroscopic screening time; Radiation dose exposure; Transforaminal nerve block

Mesh:

Year:  2018        PMID: 29911292     DOI: 10.1007/s11845-018-1845-7

Source DB:  PubMed          Journal:  Ir J Med Sci        ISSN: 0021-1265            Impact factor:   1.568


  28 in total

1.  1990 Recommendations of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  1991

2.  Transforaminal epidural steroid injections in lumbosacral radiculopathy: a prospective randomized study.

Authors:  Vijay B Vad; Atul L Bhat; Gregory E Lutz; Frank Cammisa
Journal:  Spine (Phila Pa 1976)       Date:  2002-01-01       Impact factor: 3.468

3.  Radiation exposure for fluoroscopy-guided lumbosacral epidural steroid injections: comparison of the transforaminal and caudal approaches.

Authors:  Seon-Jeong Kim; Min Hee Lee; Sheen-Woo Lee; Hye Won Chung; Sang Hoon Lee; Myung Jin Shin
Journal:  J Spinal Disord Tech       Date:  2014-02

4.  Comparison of radiation exposure during fluoroscopy-guided transforaminal epidural steroid injections at different vertebral levels.

Authors:  Yun Mi Hwang; Min Hee Lee; Seon-Jeong Kim; Sheen-Woo Lee; Hye Won Chung; Sang Hoon Lee; Myung Jin Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

5.  Epidural steroid injection: a procedure ideally performed with fluoroscopic control.

Authors:  G Y el-Khoury; S Ehara; J N Weinstein; W J Montgomery; M H Kathol
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

6.  The effect of body mass index on fluoroscopic time and radiation dose during lumbar transforaminal epidural steroid injections.

Authors:  Daniel Cushman; Ryan Mattie; Bradley Curtis; Alexandra Flis; Zachary L McCormick
Journal:  Spine J       Date:  2016-03-22       Impact factor: 4.166

7.  Severe obesity is associated with 3-fold higher radiation dose rate during ureteroscopy.

Authors:  Ryan S Hsi; David A Zamora; Kalpana M Kanal; Jonathan D Harper
Journal:  Urology       Date:  2013-08-16       Impact factor: 2.649

Review 8.  Medical interventional procedures-reducing the radiation risks.

Authors:  C Cousins; C Sharp
Journal:  Clin Radiol       Date:  2004-06       Impact factor: 2.350

Review 9.  Impact of obesity on radiology.

Authors:  Raul N Uppot
Journal:  Radiol Clin North Am       Date:  2007-03       Impact factor: 2.303

10.  A population-based study of spinal pain among 35-45-year-old individuals. Prevalence, sick leave, and health care use.

Authors:  S J Linton; A L Hellsing; K Halldén
Journal:  Spine (Phila Pa 1976)       Date:  1998-07-01       Impact factor: 3.468

View more
  2 in total

1.  Relationship between needle depth for lumbar transforaminal epidural injection and patients' height and weight using magnetic resonance imaging.

Authors:  Hyunji John; Kyomin Sohn; Jae Hun Kim
Journal:  Korean J Pain       Date:  2022-07-01

2.  Use of a steerable microcatheter during superselective angiography: impact on radiation exposure and procedural efficiency.

Authors:  Jason C Hoffmann; Jonathan Minkin; Nicholas Primiano; Jung Yun; Abieyuwa Eweka
Journal:  CVIR Endovasc       Date:  2019-11-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.