| Literature DB >> 29911088 |
Sergio Figueiredo1, Ana Daniela Pereira1, Marta Santos Silva2, Luciana Leite2, Graça Costa2, Cesar Silva2.
Abstract
OBJECTIVE: Evaluation of rheumatoid hand-associated metacarpophalangeal joint silicone arthroplasty most often relies on functional scores alone. This study aimed to understand the correlation between perceived and observed function, strength, and alignment.Entities:
Keywords: Arthritis, Rheumatoid; Arthroplasty; Hand strength; Metacarpophalangeal joint; Silicones
Year: 2017 PMID: 29911088 PMCID: PMC6001398 DOI: 10.1016/j.rboe.2017.03.012
Source DB: PubMed Journal: Rev Bras Ortop ISSN: 2255-4971
Fig. 1Determination of the angle formed by the distal phalanx of both the thumb and the index finger (D1–2α), in a lateral “OK sign” side X-ray.
Fig. 2Determination of the index formed by the minor (a) over major (b) diameters of the ellipse formed by the first and second fingers, in a lateral “OK sign” side X-ray.
Collected measurement data regarding perceived (MHQ) and objective (PP) functions, strength (key-pinch and grip) and alignment (through X-ray measurements).
| Median | P25–P75 | |
|---|---|---|
| 21.00 | 48.00 | |
| 1. General score | 41.18 | 43.64 |
| 2. Work score | 25.00 | 55.00 |
| 3. Pain score | 25.00 | 65.00 |
| 4. Appearance score | 12.50 | 32.25 |
| 5. Final questions score | 5.17 | 70.83 |
| 1. Affected hand score (30 s) | 10 | 6 |
| 2. Assembly score (60 s) | 15 | 10 |
| 1. Tip-pinch | 3.00 | 1.50 |
| 2. Grip | 5.00 | 4.00 |
| 1. Distal phalanx D1–D2 angle (°) | 91.0 | 70.8 |
| 2. D1–D2 ellipse: minor over major diameter index | 0.55 | 0.20 |
Correlation analysis of the different variables using Spearman's test.
| Spearman's correlation “ | A. MHQ | B.1. PPAHS | B.2. PPAS | C.1. Pinch S. | C.2. Grip S. | D.1. X-ray D1–2α | D.2. X-ray ellipse |
|---|---|---|---|---|---|---|---|
| A. MHQ | 1.000 | 0.702 (0.004) | 0.521 (0.047) | 0.746 (<0.001) | 0.298 (0.280) | −0.323 (0.240) | −0.257 (0.354) |
| B.1. PPAHS | 1.000 | 0.675 (0.006) | 0.659 (0.008) | 0.191 (0.496) | −0.148 (0.598) | −0.076 (0.789) | |
| B.2. PPAS | 1.000 | 0.850 (<0.001) | 0.677 (0.006) | −0.543 (0.037) | −0.619 (0.014) | ||
| C.1. Pinch S. | 1.000 | 0.643 (0.010) | −0.627 (<0.001) | −0.581 (0.002) | |||
| C.2. Grip S. | 1.000 | −0.798 (<0.001) | −0.720 (0.002) | ||||
| D.1. X-ray D1–2α | 1.000 | 0.533 (0.041) | |||||
| D.2. X-ray ellipse | 1.000 |
MHQ, Michigan Hand Outcomes Questionnaire, total score; PPAHS, Purdue Pegboard's test affected hand score; PPAS, Purdue Pegboard's test assembly score; Pinch S., key pinch strength; Grip S., grip strength; X-ray D1–2α, Thumb-index finger distal phalanx “OK-sign” side angle; X-ray ellipse, index of minor over major elliptical diameter formed by the “OK-sign”.