K B Casaletto1, F M Elahi2, R Fitch2, S Walters2, E Fox2, A M Staffaroni2, B M Bettcher3, H Zetterberg4, A Karydas2, J C Rojas2, A L Boxer2, J H Kramer2. 1. Memory and Aging Center, University of California, San Francisco, Department of Neurology, 675 Nelson Rising Lane, San Francisco, CA 94158, United States. Electronic address: kaitlin.casaletto@ucsf.edu. 2. Memory and Aging Center, University of California, San Francisco, Department of Neurology, 675 Nelson Rising Lane, San Francisco, CA 94158, United States. 3. University of Colorado, Denver Anschutz Medical Center, 13001 E 17th Fl, Aurora, CO 80045, United States. 4. Department of Psychiatry and Neurochemistry, Institute of Neuroscience and Physiology, University of Gothenburg, Sahlgrenska University Hospital, SE-43180 Mölndal, Sweden; Clinical Neurochemistry Laboratory, Sahlgrenska University Hospital, SE-43180 Mölndal, Sweden; Department of Molecular Neuroscience, UCL Institute of Neurology, Queen Square, London WC1N 3BG, United Kingdom; UK Dementia Research Institute at UCL, London WC1N 3BG, United Kingdom.
Abstract
BACKGROUND: Quantification of biofluid cytokines is a rapidly growing area of translational research. However, comparability across the expanding number of available assay platforms for detection of the same proteins remains to be determined. We aimed to directly compare a panel of commonly measured cytokines in plasma of typically aging adults across two high sensitivity quantification platforms, Meso Scale Discovery high performance electrochemiluminiscence (HPE) and single-molecule immunosorbent assays (Simoa) by Quanterix. METHODS: 57 community-dwelling older adults completed a blood draw, neuropsychological assessment, and brain MRI as part of a healthy brain aging study. Plasma samples from the same draw dates were analyzed for IL-10, IP-10, IL-6, TNFα, and IL-1β on HPE and Simoa, separately. Reliable detectability (coefficient of variance (CV) < 20% and outliers 3 interquartiles above the median removed), intra-assay precision, absolute concentrations, reproducibility across platforms, and concurrent associations with external variables of interest (e.g., demographics, peripheral markers of vascular health, and brain health) were examined. RESULTS: The proportion of cytokines reliably measured on HPE (87.7-93.0%) and Simoa (75.4-93.0%) did not differ (ps > 0.32), with the exception of IL-1β which was only reliably measured using Simoa (68.4%). On average, CVs were acceptable at <8% across both platforms. Absolute measured concentrations were higher using Simoa for IL-10, IL-6, and TNFα (ps < 0.05). HPE and Simoa shared only small-to-moderate proportions of variance with one another on the same cytokine proteins (range: r = 0.26 for IL-10 to r = 0.64 for IL-6), though platform agreement did not dependent on cytokine concentrations. Cytokine ratios within each platform demonstrated similar relative patterns of up- and down-regulation across HPE and Simoa, though still significantly differed (ps < 0.001). Supporting concurrent validity, all 95% confidence intervals of the correlations between cytokines and external variables overlapped between the two platforms. Moreover, most associations were in expected directions and consistently so across platforms (e.g., IL-6 and TNFα), though with several notable exceptions for IP-10 and IL-10. CONCLUSIONS: HPE and Simoa showed comparable detectability and intra-assay precision measuring a panel of commonly examined cytokine proteins, with the exception of IL-1β which was not reliably detected on HPE. However, Simoa demonstrated overall higher concentrations and the two platforms did not show agreement when directly compared against one another. Relative cytokine ratios and associations demonstrated similar patterns across platforms. Absolute cytokine concentrations may not be directly comparable across platforms, may be analyte dependent, and interpretation may be best limited to discussion of relative associations.
BACKGROUND: Quantification of biofluid cytokines is a rapidly growing area of translational research. However, comparability across the expanding number of available assay platforms for detection of the same proteins remains to be determined. We aimed to directly compare a panel of commonly measured cytokines in plasma of typically aging adults across two high sensitivity quantification platforms, Meso Scale Discovery high performance electrochemiluminiscence (HPE) and single-molecule immunosorbent assays (Simoa) by Quanterix. METHODS: 57 community-dwelling older adults completed a blood draw, neuropsychological assessment, and brain MRI as part of a healthy brain aging study. Plasma samples from the same draw dates were analyzed for IL-10, IP-10, IL-6, TNFα, and IL-1β on HPE and Simoa, separately. Reliable detectability (coefficient of variance (CV) < 20% and outliers 3 interquartiles above the median removed), intra-assay precision, absolute concentrations, reproducibility across platforms, and concurrent associations with external variables of interest (e.g., demographics, peripheral markers of vascular health, and brain health) were examined. RESULTS: The proportion of cytokines reliably measured on HPE (87.7-93.0%) and Simoa (75.4-93.0%) did not differ (ps > 0.32), with the exception of IL-1β which was only reliably measured using Simoa (68.4%). On average, CVs were acceptable at <8% across both platforms. Absolute measured concentrations were higher using Simoa for IL-10, IL-6, and TNFα (ps < 0.05). HPE and Simoa shared only small-to-moderate proportions of variance with one another on the same cytokine proteins (range: r = 0.26 for IL-10 to r = 0.64 for IL-6), though platform agreement did not dependent on cytokine concentrations. Cytokine ratios within each platform demonstrated similar relative patterns of up- and down-regulation across HPE and Simoa, though still significantly differed (ps < 0.001). Supporting concurrent validity, all 95% confidence intervals of the correlations between cytokines and external variables overlapped between the two platforms. Moreover, most associations were in expected directions and consistently so across platforms (e.g., IL-6 and TNFα), though with several notable exceptions for IP-10 and IL-10. CONCLUSIONS: HPE and Simoa showed comparable detectability and intra-assay precision measuring a panel of commonly examined cytokine proteins, with the exception of IL-1β which was not reliably detected on HPE. However, Simoa demonstrated overall higher concentrations and the two platforms did not show agreement when directly compared against one another. Relative cytokine ratios and associations demonstrated similar patterns across platforms. Absolute cytokine concentrations may not be directly comparable across platforms, may be analyte dependent, and interpretation may be best limited to discussion of relative associations.
Authors: Susumu Mori; Kenichi Oishi; Hangyi Jiang; Li Jiang; Xin Li; Kazi Akhter; Kegang Hua; Andreia V Faria; Asif Mahmood; Roger Woods; Arthur W Toga; G Bruce Pike; Pedro Rosa Neto; Alan Evans; Jiangyang Zhang; Hao Huang; Michael I Miller; Peter van Zijl; John Mazziotta Journal: Neuroimage Date: 2008-01-03 Impact factor: 6.556
Authors: Elizabeth Crabb Breen; Sandra M Reynolds; Christopher Cox; Lisa P Jacobson; Larry Magpantay; Candice B Mulder; Oliver Dibben; Joseph B Margolick; Jay H Bream; Elise Sambrano; Otoniel Martínez-Maza; Elizabeth Sinclair; Persephone Borrow; Alan L Landay; Charles R Rinaldo; Philip J Norris Journal: Clin Vaccine Immunol Date: 2011-06-22
Authors: Mark Jenkinson; Christian F Beckmann; Timothy E J Behrens; Mark W Woolrich; Stephen M Smith Journal: Neuroimage Date: 2011-09-16 Impact factor: 6.556
Authors: Eleftherios Garyfallidis; Matthew Brett; Bagrat Amirbekian; Ariel Rokem; Stefan van der Walt; Maxime Descoteaux; Ian Nimmo-Smith Journal: Front Neuroinform Date: 2014-02-21 Impact factor: 4.081
Authors: Cutter A Lindbergh; Kaitlin B Casaletto; Adam M Staffaroni; Fanny Elahi; Samantha M Walters; Michelle You; John Neuhaus; Will Rivera Contreras; Paul Wang; Anna Karydas; Jesse Brown; Amy Wolf; Howie Rosen; Yann Cobigo; Joel H Kramer Journal: J Gerontol A Biol Sci Med Sci Date: 2020-07-13 Impact factor: 6.053
Authors: Heather C Lasseter; Allison C Provost; Lauren E Chaby; Nikolaos P Daskalakis; Magali Haas; Andreas Jeromin Journal: Cytokine X Date: 2020-04-28
Authors: Cutter A Lindbergh; Breton M Asken; Kaitlin B Casaletto; Fanny M Elahi; Lauren A Goldberger; Corrina Fonseca; Michelle You; Alexandra C Apple; Adam M Staffaroni; Ryan Fitch; Will Rivera Contreras; Paul Wang; Anna Karydas; Joel H Kramer Journal: J Gerontol A Biol Sci Med Sci Date: 2021-10-13 Impact factor: 6.591
Authors: Breton M Asken; Lawren VandeVrede; Julio C Rojas; Corrina Fonseca; Adam M Staffaroni; Fanny M Elahi; Cutter A Lindbergh; Alexandra C Apple; Michelle You; Sophia Weiner-Light; Nivetha Brathaban; Nicole Fernandes; Adam L Boxer; Bruce L Miller; Howie J Rosen; Joel H Kramer; Kaitlin B Casaletto Journal: J Int Neuropsychol Soc Date: 2021-06-22 Impact factor: 3.114
Authors: Breton M Asken; Fanny M Elahi; Renaud La Joie; Amelia Strom; Adam M Staffaroni; Cutter A Lindbergh; Alexandra C Apple; Michelle You; Sophia Weiner-Light; Nivetha Brathaban; Nicole Fernandes; Anna Karydas; Paul Wang; Julio C Rojas; Adam L Boxer; Bruce L Miller; Gil D Rabinovici; Joel H Kramer; Kaitlin B Casaletto Journal: J Alzheimers Dis Date: 2020 Impact factor: 4.160