Literature DB >> 29904286

Utility of venous blood gases in severe sepsis and septic shock.

Heath D White1, Alfredo Vazquez-Sandoval1, Pedro F Quiroga2, Juhee Song3, Shirley F Jones1, Alejandro C Arroliga1.   

Abstract

Acid-base status is frequently assessed in severe sepsis and septic shock. Venous blood gas sampling is proposed as a less-invasive modality but lacks evidence within this population. The objective of this study was to evaluate the correlation and agreement between arterial blood gas (ABG), peripheral venous blood gas (pVBG), and central venous blood gas (cVBG) in severe sepsis and septic shock. We conducted a prospective, observational cohort study in subjects admitted to the medical intensive care unit. Simultaneous blood gas samples, including ABG, pVBG, and cVBG, were analyzed for correlation and agreement. Severity of illness scores revealed a mean (±SD) Sequential Organ Failure Assessment score of 7.9 ± 3.3, Simplified Acute Physiology II score of 49.3 ± 16.5, and a mortality rate of 11.9% in the intensive care unit and 16.4% in the hospital. We found a strong intraclass correlation (>0.85) for pH, partial pressure of carbon dioxide (pCO2), bicarbonate, and base excess for ABG/pVBG, ABG/cVBG, and pVBG/cVBG comparisons. Agreement by the Bland-Altman method was found for pH (bias ± SD, 0.03 ± 0.04, 0.03 ± 0.02, and 0.00 ± 0.03) but not for pCO2, partial pressure of oxygen, bicarbonate, base excess, and oxyhemoglobin saturation. In conclusion, adequate correlation and agreement between ABG/pVBG, ABG/cVBG, and pVBG/cVBG comparisons was found only for pH. The current level of evidence does not support the use of venous blood gas sampling in this setting.

Entities:  

Keywords:  Blood gas; septic shock; severe sepsis

Year:  2018        PMID: 29904286      PMCID: PMC5997042          DOI: 10.1080/08998280.2018.1460133

Source DB:  PubMed          Journal:  Proc (Bayl Univ Med Cent)        ISSN: 0899-8280


  28 in total

1.  Venous pCO(2) and pH can be used to screen for significant hypercarbia in emergency patients with acute respiratory disease.

Authors:  Anne-Maree Kelly; Elizabeth Kyle; Ross McAlpine
Journal:  J Emerg Med       Date:  2002-01       Impact factor: 1.484

2.  Correlation between acid-base parameters measured in arterial blood and venous blood sampled peripherally, from vena cavae superior, and from the pulmonary artery.

Authors:  Marianne Toftegaard; Stephen E Rees; Steen Andreassen
Journal:  Eur J Emerg Med       Date:  2008-04       Impact factor: 2.799

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Prediction of arterial blood gas values from venous blood gas values in patients with acute exacerbation of chronic obstructive pulmonary disease.

Authors:  Ahmet Ak; Cemile Oztin Ogun; Aysegul Bayir; Seyit Ali Kayis; Ramazan Koylu
Journal:  Tohoku J Exp Med       Date:  2006-12       Impact factor: 1.848

Review 5.  Peripheral venous and arterial blood gas analysis in adults: are they comparable? A systematic review and meta-analysis.

Authors:  Anthony L Byrne; Michael Bennett; Robindro Chatterji; Rebecca Symons; Nathan L Pace; Paul S Thomas
Journal:  Respirology       Date:  2014-01-03       Impact factor: 6.424

6.  Comparison of arterial and venous blood gas values in the initial emergency department evaluation of patients with diabetic ketoacidosis.

Authors:  M A Brandenburg; D J Dire
Journal:  Ann Emerg Med       Date:  1998-04       Impact factor: 5.721

7.  Use of the SOFA score to assess the incidence of organ dysfunction/failure in intensive care units: results of a multicenter, prospective study. Working group on "sepsis-related problems" of the European Society of Intensive Care Medicine.

Authors:  J L Vincent; A de Mendonça; F Cantraine; R Moreno; J Takala; P M Suter; C L Sprung; F Colardyn; S Blecher
Journal:  Crit Care Med       Date:  1998-11       Impact factor: 7.598

8.  Comparison of arterial and venous pH, bicarbonate, PCO2 and PO2 in initial emergency department assessment.

Authors:  G Malatesha; Nishith K Singh; Ankur Bharija; Bhavya Rehani; Ashish Goel
Journal:  Emerg Med J       Date:  2007-08       Impact factor: 2.740

9.  Can peripheral venous blood gases replace arterial blood gases in emergency department patients?

Authors:  Louise C F Rang; Heather E Murray; George A Wells; Cameron K Macgougan
Journal:  CJEM       Date:  2002-01       Impact factor: 2.410

10.  Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in Kashmir valley of the Indian subcontinent.

Authors:  Parvaiz A Koul; Umar Hafiz Khan; Abdul Ahad Wani; Rafiqa Eachkoti; Rafi A Jan; Sanaullah Shah; Zarka Masoodi; Syed Mudassir Qadri; Muneer Ahmad; Asrar Ahmad
Journal:  Ann Thorac Med       Date:  2011-01       Impact factor: 2.219

View more
  2 in total

1.  Electrochemical deposition of highly hydrophobic perfluorinated polyaniline film for biosensor applications.

Authors:  Elena Tomšík; Panagiotis Dallas; Ivana Šeděnková; Jan Svoboda; Martin Hrubý
Journal:  RSC Adv       Date:  2021-05-25       Impact factor: 4.036

2.  Venous blood for the analysis of acid-base status in a model of septic shock.

Authors:  Matthew J Maiden; Jonathan D Fraser; Mark E Finnis
Journal:  Emerg Med Australas       Date:  2022-04-09       Impact factor: 2.279

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.