Evaluation of MRI RF electromagnetic field induced heating near leads of cochlear implants.

Qi Zeng1, Qinyan Wang, Jianfeng Zheng, Wolfgang Kainz, Ji Chen.   

Abstract

A typical cochlear implant system under magnetic resonance imaging (MRI) procedures may couple with the radio frequency (RF) electromagnetic field (EMF) and results in an intensified electric field at the lead tip. As a result, the RF energy deposited in human tissues around the lead tip may induce heating and cause tissue damage concerns. The purpose of this work is to evaluate the RF-EMF-induced heating for cochlear implant system in 1.5 T MRI coil and highlight the factors that have significant effects on the heating. The potential factors involved in the RF-EMF-induced heating including the lead type, lead trajectory, human model and MRI landmark. In this paper, the RF-EMF-induced heating for three types of leads is evaluated in two virtual human models. A total of 24 lead trajectories and 23 anatomical landmark positions are studied using the transfer function method. The average temperature rise for all the studied cases in the human models is 0.79 °C, and the maximum value is 2.80 °C for a maximum whole-body average specific absorption rate of 2 W kg-1 in an RF body coil. It is found that the lead trajectory and MRI landmark are two primary influencing factors. The maximum temperature rises for different lead trajectories can vary from 0.82 to 2.80 °C. A difference in heating of 2.80 °C is observed when the landmark changes from  -100 to 700 mm. This work demonstrates that it is necessary to take these factors into account when evaluating the RF-EMF-induced heating for implanted medical devices.

Entities:  

Mesh:

Year:  2018        PMID: 29893289     DOI: 10.1088/1361-6560/aacbf2

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

Review 1.  [MR safety assessment of active implanted medical devices. German version].

Authors:  Sarra Aissani; Elmar Laistler; Jacques Felblinger
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

Review 2.  MR safety assessment of active implantable medical devices.

Authors:  Sarra Aissani; Elmar Laistler; Jacques Felblinger
Journal:  Radiologe       Date:  2019-12       Impact factor: 0.635

3.  Modeling radiofrequency responses of realistic multi-electrode leads containing helical and straight wires.

Authors:  Mikhail Kozlov; Marc Horner; Wolfgang Kainz
Journal:  MAGMA       Date:  2019-11-19       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.