Iterative Minimum Variance Beamformer with Low Complexity for Medical Ultrasound Imaging.

Ali Mohades Deylami1, Babak Mohammadzadeh Asl2.   

Abstract

Minimum variance beamformer (MVB) improves the resolution and contrast of medical ultrasound images compared with delay and sum (DAS) beamformer. The weight vector of this beamformer should be calculated for each imaging point independently, with a cost of increasing computational complexity. The large number of necessary calculations limits this beamformer to application in real-time systems. A beamformer is proposed based on the MVB with lower computational complexity while preserving its advantages. This beamformer avoids matrix inversion, which is the most complex part of the MVB, by solving the optimization problem iteratively. The received signals from two imaging points close together do not vary much in medical ultrasound imaging. Therefore, using the previously optimized weight vector for one point as initial weight vector for the new neighboring point can improve the convergence speed and decrease the computational complexity. The proposed method was applied on several data sets, and it has been shown that the method can regenerate the results obtained by the MVB while the order of complexity is decreased from O(L3) to O(L2).
Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

Keywords:  Adaptive beamformer; Low complexity; Medical ultrasound imaging; Minimum variance beamformer

Mesh:

Year:  2018        PMID: 29880249     DOI: 10.1016/j.ultrasmedbio.2018.04.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Combining ADMIRE and MV to Improve Image Quality.

Authors:  Siegfried Schlunk; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-08-26       Impact factor: 3.267

2.  Minimum variance beamforming combined with covariance matrix-based adaptive weighting for medical ultrasound imaging.

Authors:  Yuanguo Wang; Yadan Wang; Mingzhou Liu; Zhengfeng Lan; Chichao Zheng; Hu Peng
Journal:  Biomed Eng Online       Date:  2022-06-18       Impact factor: 3.903

3.  Multiplexed ultrasound beam summation for side lobe reduction.

Authors:  Asaf Ilovitsh; Tali Ilovitsh; Katherine W Ferrara
Journal:  Sci Rep       Date:  2019-09-27       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.