Literature DB >> 29869074

Critical evaluation of an innovative mesh for bilateral transabdominal preperitoneal (TAPP) repair of inguinal hernias.

G Köhler1,2,3,4,5, I Fischer6,7,8,9, R Kaltenböck6,7,8,9, M Mitteregger10, G Seitinger10, A Szyszkowitz10.   

Abstract

PURPOSE: Transabdominal preperitoneal hernia mesh plasty (TAPP) offers significant benefits to patients undergoing bilateral inguinal hernia repair. We evaluated a novel pre-shaped, large-pored, titanium-coated, lightweight polypropylene mesh for bilateral placement as an alternative to two separate meshes.
METHODS: Thirty-six patients underwent elective surgical repair of bilateral inguinal hernias with the new mesh at three departments of surgery in Linz and Graz, Austria, between May 1, 2015 and June 30, 2017.
RESULTS: All operations were completed without intraoperative complications or conversion to open procedures. The mean operation time was 74 min. There were no postoperative procedure-related complications with the exception of one hematoseroma of the spermatic cord. Two symptomatic medial recurrences (2/36 patients = 5.6%, 2/72 hernia repairs = 2.8%, respectively) after supravesical and medial hernia repair with the bilateral mesh were seen at structured follow-up examinations 6 and 12 months postoperatively.
CONCLUSION: Treatment of bilateral inguinal hernias with the newly designed bilateral mesh for TAPP theoretically brings benefits in terms of resistance to forces acting on the mesh. The larger area may decrease the risk for mesh bulging and recurrence, and one large mesh might provide more stable support than two separate meshes overlapping at the midline. The results of our study do not confirm these theoretical benefits regarding a high recurrence rate (2.8%) after treatment of medial hernia defects. We recommend re-designing the mesh with only a small central slit, which would provide a broader mesh bridge with sufficient overlap for all types of inguinal and femoral hernias, including medial and supravesical defects. After the mesh has been re-designed, a new study should evaluate its real benefits before it is marketed.

Entities:  

Keywords:  Groin hernia; Inguinal hernia; TAPP; Transabdominal preperitoneal patch plasty

Mesh:

Substances:

Year:  2018        PMID: 29869074     DOI: 10.1007/s10029-018-1786-0

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  20 in total

Review 1.  Meta-analysis of randomized trials comparing nonpenetrating vs mechanical mesh fixation in laparoscopic inguinal hernia repair.

Authors:  Stavros A Antoniou; Gernot Köhler; George A Antoniou; Filip E Muysoms; Rudolph Pointner; Frank-Alexander Granderath
Journal:  Am J Surg       Date:  2015-07-31       Impact factor: 2.565

2.  The space of Bogros and the deep inguinal venous circulation.

Authors:  R Bendavid
Journal:  Surg Gynecol Obstet       Date:  1992-05

Review 3.  Lightweight versus heavyweight mesh in laparoscopic inguinal hernia repair: a meta-analysis.

Authors:  Andrew Currie; Helen Andrew; Alfredo Tonsi; Paul R Hurley; Sanjay Taribagil
Journal:  Surg Endosc       Date:  2012-02-07       Impact factor: 4.584

4.  [Original procedure of groin hernia repair: interposition without fixation of Dacron tulle prosthesis by subperitoneal median approach].

Authors:  R Stoppa; J Petit; H Abourachid; X Henry; C Duclaye; G Monchaux; J P Hillebrant
Journal:  Chirurgie       Date:  1973-02

Review 5.  Small bowel obstruction after TAPP repair caused by a self-anchoring barbed suture device for peritoneal closure: case report and review of the literature.

Authors:  G Köhler; F Mayer; M Lechner; R Bittner
Journal:  Hernia       Date:  2014-08-12       Impact factor: 4.739

Review 6.  The European hernia society groin hernia classification: simple and easy to remember.

Authors:  M Miserez; J H Alexandre; G Campanelli; F Corcione; D Cuccurullo; M Hidalgo Pascual; A Hoeferlin; A N Kingsnorth; V Mandala; J P Palot; V Schumpelick; R K J Simmermacher; R Stoppa; J B Flament
Journal:  Hernia       Date:  2007-03-13       Impact factor: 4.739

Review 7.  [Repair of bilateral inguinal hernias--sequential or simultaneous?].

Authors:  F Pfeffer; H Riediger; R Küfner Lein; U T Hopt
Journal:  Zentralbl Chir       Date:  2008-10-15       Impact factor: 0.942

8.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

9.  Five-year results of a randomized clinical trial comparing a polypropylene mesh with a poliglecaprone and polypropylene composite mesh for inguinal hernioplasty.

Authors:  K Bury; M Śmietański
Journal:  Hernia       Date:  2012-05-10       Impact factor: 4.739

10.  When is mesh fixation in TAPP-repair of primary inguinal hernia repair necessary? The register-based analysis of 11,230 cases.

Authors:  F Mayer; H Niebuhr; M Lechner; A Dinnewitzer; G Köhler; M Hukauf; R H Fortelny; R Bittner; F Köckerling
Journal:  Surg Endosc       Date:  2016-02-17       Impact factor: 4.584

View more
  1 in total

1.  Laparoscopic bilateral groin hernia repair with one large self-fixating mesh: prospective observational study with patient-reported outcome of urological symptoms and EuraHS-QoL scores.

Authors:  Filip Muysoms; Maxime Dewulf; Iris Kyle-Leinhase; Rita Baumgartner; Filip Ameye; Barbara Defoort; Pieter Pletinckx
Journal:  Surg Endosc       Date:  2019-05-28       Impact factor: 4.584

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.