Literature DB >> 26886454

When is mesh fixation in TAPP-repair of primary inguinal hernia repair necessary? The register-based analysis of 11,230 cases.

F Mayer1, H Niebuhr2, M Lechner3, A Dinnewitzer3, G Köhler4, M Hukauf5, R H Fortelny6, R Bittner7, F Köckerling8.   

Abstract

Whereas for TEP the guidelines do not recommend mesh fixation on the basis of meta-analyses regardless of the defect size, for TAPP mesh fixation can be omitted only up to a defect size of 3 cm because of the paucity of studies on this topic. Hence, this study now seeks to explore this subject on the basis of prospective data from the Herniamed Hernia Registry. In the period September 01, 2009, to January 31, 2014, 11,228 male patients were operated on with the TAPP technique for a primary unilateral inguinal hernia and were followed up for 1 year. Mesh fixation was used for 7422 (66.1 %) of these patients and no mesh fixation for 3806 patients (33.9 %). Unadjusted analysis did not find any significant difference in the recurrence rate (0.88 % with fixation vs. 1.1 % without fixation; p = 0.259). Multivariable analysis of all potential influence factors (age, ASA, BMI, risk factors, defect size, mesh fixation, localization of defect, mesh size) did not identify any factor that impacted recurrence on 1-year follow-up. Only for medial and combined defect localization versus lateral localization was a highly significant effect identified (p < 0.001). With mesh fixation and larger mesh size, it was possible to significantly reduce the recurrence rate for larger medial hernias in this series (p = 0.046). For TAPP repair of an inguinal hernia, mesh fixation is not necessary in a significant number of patients. Patients with a medial and combined hernia are at higher risk of recurrence. In the patient series analyzed, it was possible to significantly reduce the recurrence rate with mesh fixation and larger mesh size for medial defects.

Entities:  

Keywords:  Inguinal hernia; Medial hernia; Mesh fixation; Recurrence; TAPP

Mesh:

Year:  2016        PMID: 26886454      PMCID: PMC5009149          DOI: 10.1007/s00464-016-4754-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


The longstanding standard practice for TAPP was to use mesh fixation with tackers to prevent recurrence [1]. But atraumatic mesh fixation fibrin sealants are being increasingly employed to prevent chronic pain in the wake of traumatic fixation methods [2]. Numerous studies have attested to the excellent results in terms of the recurrence rate achieved with fibrin sealants for atraumatic mesh fixation [3-6]. Comparative studies then explored, in particular for the total extraperitoneal patchplasty (TEP), whether mesh fixation could be completely dispensed with [7, 8]. In the guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia of the International Endohernia Society (IEHS), a statement with level of evidence 1 B pointed out that fixation and non-fixation of the mesh were associated with equally low recurrence rates in both TAPP and TEP [9]. However, in most studies the hernia opening was small (<3 cm) or not measured [9]. Therefore, the guidelines recommended that when using TAPP or TEP techniques non-fixation could be considered for types L I, II, and M I, II hernias (EHS classification) [9]. For TAPP and TEP repair of big defects (L III, M III), the mesh should be fixed [9]. In an update of the Guidelines of the International Endohernia Society, ten new studies with evidence level 1 have been included. For TEP, with evidence level 1 A, these stated that fixation and non-fixation of the mesh in TEP were associated with an equal risk of recurrence [10]. For TAPP, the recommendations remained unchanged. Hence, in the case of TAPP it remained unclear whether mesh fixation was needed to prevent recurrence, at least for defect sizes >3 cm (EHS classification L III, M III). Therefore, this paper now seeks to explore this subject on the basis of prospective data of the Herniamed Hernia Registry.

Patients and methods

As of March, 19, 2015, 426 participating hospitals and office-based surgeons mainly from Germany, Austria, and Switzerland had entered prospective data into the multicenter internet-based Herniamed Hernia Registry on their patients who had undergone hernia surgery [11]. This present study analyzed the prospective data collected for all male patients who had been operated on with an endoscopic TAPP technique for repair of a primary unilateral inguinal hernia in the period September 01, 2009, up to and including January 31, 2014. On 1-year follow-up, the general practitioner and patients were asked by questionnaire about any recurrences. Only those patients for whom 1-year follow-up results were available were included in the analysis. Other inclusion criteria included: age >16 years and medial/lateral/combined types of inguinal hernia based on the EHS classification [12]. In total, 11,228 patients were included in uni- and multivariate analysis for investigation of the impact of mesh fixation as well as of other potential influence factors impacting onset of a recurrence during the 1-year follow-up of TAPP operation. Details of all enrolled patients regarding the documented hernia defect size are given in Table 1 and of the fixation method in Table 2. During the observation period, 7422 patients (66.1 %) were operated on while using mesh fixation and 3806 patients (33.9 %) without mesh fixation.
Table 1

Distribution of defect size and fixation/non-fixation

Size of defectTotal
I (<1.5 cm)II (1.5–3 cm)III (>3 cm)
n % n % n % n %
Mesh fixation85256.76465262.91191882.25742266.10
No mesh fixation64943.24274337.0941417.75380633.90
Total1501100.007395100.002332100.0011,228100.00
Table 2

Distribution of defect size in the group with mesh fixation and fixation type

Size of defectTotal
I (<1.5 cm)II (1.5–3 cm)III (>3 cm)
n % n % n % n %
Type of fixation
 Suture12114.2076016.3444623.25132717.88
 Tacker39346.13221947.7095649.84356848.07
 Glue33138.85160734.5446824.40240632.42
 Combination70.82661.42482.501211.63
Total852100.004652100.001918100.007422100.00
Distribution of defect size and fixation/non-fixation Distribution of defect size in the group with mesh fixation and fixation type All analyses were performed with the software SAS 9.2 (SAS institute Inc., Cary, NY, USA) and intentionally calculated to a full significance level of 5 %, i.e., they were not corrected in respect of multiple tests, and each p value ≤ 0.05 represents a significant result. Unadjusted analyses were carried out to analyze how any individual influence variable affected an outcome parameter. For categorical target (outcome) variables, Fisher’s exact test was applied. For continuous target variables that followed the normal distribution, the robust t test (Satterthwaite) was used. To eliminate the effect of any confounders arising from different characteristics related to the patient or surgical technique, the results of unadjusted analysis were verified once again in multivariable analysis. In addition to fixation (yes/no), it was also possible to simultaneously review all the other influence factors. The binary regression model for dichotomous target variables was used to identify the influence of the various factors in multivariable analysis. Odds ratios (OR) and corresponding 95 % confidence intervals based on the Wald test are given for estimates. For influence variables with more than two categories, one of these values was used in each case as a reference category. For the continuous variable age (years), the 10-year odds ratio is given, for BMI (kg/m2) a five-point odds ratio, and for mesh size the ten-point odds ratio. The results are sorted on the basis of influence and presented in tabular form.

Results

Unadjusted results

Unadjusted analysis of the groups compared, i.e., TAPP with versus without mesh fixation, revealed, in some cases, significant differences in the patient characteristics and hernia findings (Table 3). The patients in the mesh fixation group were significantly older (57.4 years ± 14.8 vs. 54.4 years ± 15.7 [mean ± STD], p < 0.001), and larger meshes were used (151.1 cm2 ± 19.3 vs. 145.8 cm2 ± 15.6 [mean ± STD], p < 0.001). For large hernia defects (EHS III), the mesh was fixed significantly more often (82.2 % with mesh fixation vs. 17.8 % without mesh fixation) (Table 1). Likewise, for a medial hernia the implanted mesh was fixed significantly more often (30.8 % with mesh fixation vs. 24.9 % without mesh fixation; p < 0.001) (Table 3). A clear difference was identified between the two groups with regard to the presence of at least one risk factor (p = 0.011). A large proportion, at 25.8 %, of patients without mesh fixation had at least one relevant risk factor compared with those without mesh fixation, at 23.6 % (p = 0.001). That was also true for nicotine abuse (12.4 % without mesh fixation vs. 8.7 % with mesh fixation; p < 0.001).
Table 3

Demographic and surgery-related data

Mesh fixationNo mesh fixation p
Age (years)Mean ± STD57.4 ± 14.854.4 ± 15.7<0.001
BMI (kg/m²)Mean ± STD25.9 ± 3.425.9 ± 3.30.573
Mesh size (cm²)Mean ± STD151.1 ± 19.3145.8 ± 15.6<0.001

Demographic parameters (Table 3) are demonstrated in relation to fixation/non-fixation and include the age of the patients (years), BMI (kg/m2), size of the mesh implant (cm2), ASA score (I–IV), size of the hernia defect (EHS I–III), localization of the hernia defect (medial-M/lateral-L/combined-C; EHS classification), and hernia-specific risk factors

Demographic and surgery-related data Demographic parameters (Table 3) are demonstrated in relation to fixation/non-fixation and include the age of the patients (years), BMI (kg/m2), size of the mesh implant (cm2), ASA score (I–IV), size of the hernia defect (EHS I–III), localization of the hernia defect (medial-M/lateral-L/combined-C; EHS classification), and hernia-specific risk factors Unadjusted analysis of the relationship between mesh fixation and non-fixation for TAPP did not reveal any significant difference in the recurrence rate on 1-year follow-up (Table 4). The recurrence rate was 0.9 % in the mesh fixation group and 1.1 % in the non-fixation group (p = 0.259).
Table 4

Unadjusted analysis of the recurrence rates on 1-year follow-up

Mesh fixationNo mesh fixation p
n % n %
Recurrent hernia (1-year follow-up: 100 %)
 Yes650.88421.100.259
 No735799.12376498.90
Unadjusted analysis of the recurrence rates on 1-year follow-up

Multivariable analysis

In this multivariable analysis (Table 5), all potential influence factors were reviewed with regard to onset of a recurrence. No relevant influence was identified for mesh fixation compared with non-fixation (p = 0.399). That was also true for the defect size (p = 0.383), with no significant difference observed on comparing defect sizes >3 cm (EHS classification III) with sizes <1.5 cm (EHS classification I) and 1.5–3 cm (EHS classification II). Nor did the mesh size have any significant impact on onset of recurrence. For the patient-related influence factors such as age, ASA score, BMI value, the risk factors COPD, and smoking as well as the other risk factors, multivariable analysis did not identify any effect on onset of recurrence. The only factor that had a highly significant impact on recurrence was hernia localization (p < 0.001). Whereas a lateral hernia was associated with a lower probability of onset of recurrence, a medial inguinal hernia and a combined hernia with a medial portion presented a highly significantly higher risk for onset of recurrence (p < 0.001). With a prevalence of 0.9 % for the entire patient collective, this would correspond to five recurrences for every 1000 operations of hernias with lateral EHS localization compared with 11 recurrences for patients with medial EHS localization. Hence, medial and combined hernias constitute a highly significant risk factor for onset of recurrence following TAPP, but that was not true for patient-related factors, hernia size, and mesh non-fixation.
Table 5

Multivariable analysis of recurrence (model fit: p = 0.004)

Parameter p valueVariablesOR95 %-CI
Localization of defect (EHS)<0.001Combined versus medial1.1370.6561.970
Lateral versus medial0.4630.3030.707
Risk factors: COPD/smoking0.097Yes versus no0.5560.2781.111
BMI (five-point OR)0.1091.2400.9531.613
Size of mesh (ten-point OR)0.1920.9290.8321.038
Size of defect (EHS)0.383I (<1.5 cm) versus III (>3 cm)1.3300.6942.546
II (1.5–3 cm) versus III (>3 cm)0.9140.5581.499
Fixation of mesh0.399No fixation versus fixation1.1940.7911.800
Risk factors (others)a 0.408Yes versus no1.2690.7212.234
ASA0.720II versus I1.1060.6831.791
III/IV versus I1.3520.6502.812
Age [10-year OR]0.8691.0130.8681.183

aRisk factors (others): immunosuppression, antiplatelet medication, coagulopathy, diabetes, corticoids, anticoagulation, aortic aneurysm

Multivariable analysis of recurrence (model fit: p = 0.004) aRisk factors (others): immunosuppression, antiplatelet medication, coagulopathy, diabetes, corticoids, anticoagulation, aortic aneurysm

Subgroup analysis

If, in view of the results of multivariable analysis, one compares the recurrence rates in unadjusted analysis in relation to the EHS localization, highly significant differences unfavorable to medial and combined hernias are seen (Table 6). If one then checks the role of fixation in the medial inguinal hernia group, which is at higher risk of recurrence, one notes that it was possible to significantly reduce the recurrence rate with mesh fixation (Table 7). No significant difference was found in the recurrence rate between the various fixation techniques (tacker, glue, suture, combination) (Table 8). In addition, where mesh fixation was used to repair medial inguinal hernias, a significantly larger mesh size was used (Table 9). Besides, analysis of the meshes used for at least 5 % of medial inguinal hernias demonstrated significant differences (Table 10). For example, one notable finding was that in the group with no mesh fixation a greater number of self-adhesive, titanized, and 3D standard meshes were used (Table 10). Since the medial sac reduction is not documented in the Herniamed Registry, no conclusions on its implications can be drawn from the data presented here.
Table 6

Comparision of recurrence rates depending on EHS localization

MedialLateralCombined p
n % n % n %
Recurrence
 Yes441.36440.65191.56<0.001
 No319098.64673299.3512011.56
Table 7

Comparision of recurrence rates in TAPP with and without mesh fixation in medial inguinal hernias

Mesh fixationNo mesh fixation p
n % n %
Recurrence
 Yes251.09192.000.046
 No226098.9192998.00
Table 8

Comparision of recurrence rates in TAPP with mesh fixation depending on type of fixation in medial inguinal hernias

SutureTackerGlueCombined p
n % n % n % n %
Recurrence
 Yes40.97161.3450.79000.746
 No40799.03118298.6662799.2144100.00
Table 9

Comparision of mesh sizes in TAPP with and without mesh fixation in medial inguinal hernias

Fixation p
Mesh fixation (n = 2285)No Mesh fixation (n = 948)
Mesh size (cm2)Mean ± STD151.0 ± 21.1145.2 ± 19.0<0.001
Table 10

Comparision of meshes used in TAPP with and without mesh fixation in medial inguinal hernias

Mesh fixationNo mesh fixation p
n % n %
Type of meshes
 Other <5 %107947.2241643.88<0.001
 Ultrapro60426.43808.44
 Parietene ProGrip60.2618619.62
 TiMesh light1848.0510711.29
 3DMax Light Mesh612.6713514.24
 Optilene Mesh LP35115.36242.53
Comparision of recurrence rates depending on EHS localization Comparision of recurrence rates in TAPP with and without mesh fixation in medial inguinal hernias Comparision of recurrence rates in TAPP with mesh fixation depending on type of fixation in medial inguinal hernias Comparision of mesh sizes in TAPP with and without mesh fixation in medial inguinal hernias Comparision of meshes used in TAPP with and without mesh fixation in medial inguinal hernias

Discussion

This present analysis of data from the Herniamed Hernia Registry compared the recurrence rates on 1-year follow-up in respect of mesh fixation versus non-fixation in TAPP. Univariable analysis did not find any significant difference between these two parameters. However, since there were significant differences between the two groups in terms of their demographic and surgery-related data, multivariable analysis was performed to identify the influence factors that significantly impacted the recurrence rate on 1-year follow-up. The latter revealed that for TAPP, too, mesh fixation did not have any relevant impact on the recurrence rate regardless of the defect size. A similar conclusion was reported by a prospective randomized trial that compared 273 TAPP operations with mesh fixation versus 263 without mesh fixation [13]. Nor did multivariable analysis find any evidence that age, ASA score, BMI value, or patient-related risk factors exerted any influence on onset of recurrence. Here it must be pointed out that unlike one systematic review [14], no effect on recurrence rate was identified for patients with either COPD or nicotine abuse. The only highly significant factor impacting onset of recurrence following TAPP for primary unilateral inguinal hernia repair in men was a medial or combined hernia based on the EHS classification. That finding was also confirmed in the systematic review by Burcharth et al. [14] which found that a direct inguinal hernia was found to be a risk factor for recurrence with a pooled RR of 1.91 (95 % CI 1.62–2.36; p < 0.001). Unlike a lateral inguinal hernia, where the peritoneal hernia sac is removed from the inguinal canal and the inguinal canal closes curtain-like, additional surgical measures are necessary taken to repair the hernia defect for the medial inguinal hernia [9, 15–19]. The content of the direct hernia cavity, generally composed of preperitoneal fat, is dissected out, leaving the hernia cavity as a rigid outpouching of the transversalis fascia. Consequently, there is a higher risk of seroma for medial inguinal hernias following endoscopic repair [9, 15–19]. This medial hernia cavity is at also greater risk of recurrence since it represents more a bridging situation compared with the lateral inguinal hernia. Therefore, the requirements for adequate overlap are more stringent. It is crucial when using an endoscopic technique (TEP, TAPP) to repair medial inguinal hernia that “complete medial sac reduction” be performed to avoid onset of seroma or recurrence. Since the lining of the medial hernia cavity is formed by the transversalis fascia outpouching, the latter is clasped and pulled inwards until the space is completely reduced (“complete medial sac reduction”) [9, 15–19]. Next, the transversalis fascia that has been pulled inwards is now either fixed with a suture to Cooper’s ligament or blocked off with a Roeder loop [18, 19]. The utmost attention should be paid to this technical step of “complete medial sac reduction” in both TAPP and TEP since it serves to prevent seromas as well as recurrence. Moreover, in this situation it may be necessary to use a mesh size of 17 × 12 cm instead of the standard size of 15 × 10 cm. For example, analysis of the subgroup of medial inguinal hernias in the Herniamed Registry did indeed reveal that in the mesh fixation group significantly larger size meshes were used. By contrast, in the group with no mesh fixation a greater number of self-adhesive, titanized and 3D standard meshes were also used. The data presented here also demonstrate that for larger medial and combined hernias additional fixation of the mesh is needed using either properly placed absorbable tackers, sutures, or atraumatic fibrin sealants. The data also show that the type of fixation did not impact the recurrence rate. In summary, it can be stated that for TAPP repair of an inguinal hernia fixation of the mesh is not needed in a significant number of patients. Patients with a medial and combined hernia are at a higher risk of recurrence. The choice of a greater mesh and “complete medial sac reduction” must be carefully made to obtain a plane inguinal region surface for mesh placement and greater mesh overlap. This helps to reduce both the recurrence and the seroma rates. The present study has demonstrated that on using mesh fixation for TAPP, regardless of whether with tacker, suture, glue, or combined, the recurrence rates for larger medial hernias were significantly lower.
  19 in total

1.  C. R. Berney: "The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach".

Authors:  F Köckerling; D A Jacob; D Lomanto; P Chowbey
Journal:  Hernia       Date:  2012-05-08       Impact factor: 4.739

2.  Guidelines for laparoscopic (TAPP) and endoscopic (TEP) treatment of inguinal hernia [International Endohernia Society (IEHS)].

Authors:  R Bittner; M E Arregui; T Bisgaard; M Dudai; G S Ferzli; R J Fitzgibbons; R H Fortelny; U Klinge; F Kockerling; E Kuhry; J Kukleta; D Lomanto; M C Misra; A Montgomery; S Morales-Conde; W Reinpold; J Rosenberg; S Sauerland; C Schug-Pass; K Singh; M Timoney; D Weyhe; P Chowbey
Journal:  Surg Endosc       Date:  2011-07-13       Impact factor: 4.584

3.  Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study.

Authors:  Federico Lovisetto; Sandro Zonta; Emanuela Rota; Massimiliano Mazzilli; Marco Bardone; Luca Bottero; Giuseppe Faillace; Mauro Longoni
Journal:  Ann Surg       Date:  2007-02       Impact factor: 12.969

4.  The Endoloop technique for the primary closure of direct inguinal hernia defect during the endoscopic totally extraperitoneal approach.

Authors:  C R Berney
Journal:  Hernia       Date:  2011-11-27       Impact factor: 4.739

5.  The impact of atraumatic fibrin sealant vs. staple mesh fixation in TAPP hernia repair on chronic pain and quality of life: results of a randomized controlled study.

Authors:  R H Fortelny; A H Petter-Puchner; C May; W Jaksch; T Benesch; Z Khakpour; H Redl; K S Glaser
Journal:  Surg Endosc       Date:  2011-08-19       Impact factor: 4.584

Review 6.  The European hernia society groin hernia classification: simple and easy to remember.

Authors:  M Miserez; J H Alexandre; G Campanelli; F Corcione; D Cuccurullo; M Hidalgo Pascual; A Hoeferlin; A N Kingsnorth; V Mandala; J P Palot; V Schumpelick; R K J Simmermacher; R Stoppa; J B Flament
Journal:  Hernia       Date:  2007-03-13       Impact factor: 4.739

7.  Outcomes of staple fixation of mesh versus nonfixation in laparoscopic total extraperitoneal inguinal repair: a meta-analysis of randomized controlled trials.

Authors:  Ka-Wai Tam; Hung-Hua Liang; Chiah-Yang Chai
Journal:  World J Surg       Date:  2010-12       Impact factor: 3.352

8.  Seroma following endoscopic extraperitoneal inguinal hernioplasty.

Authors:  H Lau; F Lee
Journal:  Surg Endosc       Date:  2003-06-17       Impact factor: 4.584

9.  Laparoscopic repair of direct inguinal hernia: a new technique that reduces the development of postoperative seroma.

Authors:  V M Reddy; C D Sutton; L Bloxham; G Garcea; S S Ubhi; G S Robertson
Journal:  Hernia       Date:  2007-06-01       Impact factor: 4.739

10.  Randomized prospective study of totally extraperitoneal inguinal hernia repair: fixation versus no fixation of mesh.

Authors:  Cody A Koch; Susan M Greenlee; Dirk R Larson; Jeffrey R Harrington; David R Farley
Journal:  JSLS       Date:  2006 Oct-Dec       Impact factor: 2.172

View more
  16 in total

1.  [Evidence-based TEP technique].

Authors:  F Köckerling
Journal:  Chirurg       Date:  2017-04       Impact factor: 0.955

Review 2.  Fibrin glue versus staple for mesh fixation in laparoscopic transabdominal preperitoneal repair of inguinal hernia: a meta-analysis and systematic review.

Authors:  Zhaoqi Shi; Xiaoxiao Fan; Shuting Zhai; Xin Zhong; Diyu Huang
Journal:  Surg Endosc       Date:  2016-06-28       Impact factor: 4.584

3.  Comment to: "Factors associated with hernia recurrence after laparoscopic total extraperitoneal repair for inguinal hernia: a 2-year prospective cohort study." By Schjøth-Iversen L. (Hernia. 2017 Jul 27. doi:10.1007/s10029-017-1634-7. [Epub ahead of print]).

Authors:  J Li; W Zhang
Journal:  Hernia       Date:  2017-09-01       Impact factor: 4.739

4.  Fixation techniques in inguinal hernia repair, what is really new?

Authors:  R H Fortelny
Journal:  Hernia       Date:  2019-09-26       Impact factor: 4.739

5.  Long-term follow-up of endoscopic totally extraperitoneal direct inguinal hernia repair using the Endoloop technique.

Authors:  Emma Clout; Mirun Thayaparan; Cameron Douglas; Christophe R Berney
Journal:  Surg Endosc       Date:  2018-11-26       Impact factor: 4.584

Review 6.  Mesh fixation in endoscopic inguinal hernia repair: evaluation of methodology based on a systematic review of randomised clinical trials.

Authors:  Hans Lederhuber; Franziska Stiede; Stephan Axer; Ursula Dahlstrand
Journal:  Surg Endosc       Date:  2017-04-14       Impact factor: 4.584

7.  Three-point mesh fixation in robot-assisted transabdominal preperitoneal (R-TAPP) repair of 208 inguinal hernias: preliminary results of a single-center consecutive series.

Authors:  Sebastiano Spampatti; Davide La Regina; Ramon Pini; Francesco Mongelli; Paolo Gaffuri; Iride Porcellini; Andrea Romanzi; Maria Marcantonio
Journal:  Langenbecks Arch Surg       Date:  2022-05-18       Impact factor: 2.895

8.  International guidelines for groin hernia management.

Authors: 
Journal:  Hernia       Date:  2018-01-12       Impact factor: 4.739

9.  Critical evaluation of an innovative mesh for bilateral transabdominal preperitoneal (TAPP) repair of inguinal hernias.

Authors:  G Köhler; I Fischer; R Kaltenböck; M Mitteregger; G Seitinger; A Szyszkowitz
Journal:  Hernia       Date:  2018-06-05       Impact factor: 4.739

10.  Seroma following transabdominal preperitoneal patch plasty (TAPP): incidence, risk factors, and preventive measures.

Authors:  F Köckerling; R Bittner; D Adolf; R Fortelny; H Niebuhr; F Mayer; C Schug-Pass
Journal:  Surg Endosc       Date:  2017-10-26       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.