| Literature DB >> 29866050 |
Peter Magnusson1,2, Per Liv3.
Abstract
BACKGROUND: The aim of this study was to assess among pacemaker patients their overall satisfaction with the pacemaker system, pain, soreness/discomfort, cosmetic results, restrictions due to impaired movement of the shoulder/arm/chest, related sleep disturbances, and concern about possible device malfunction.Entities:
Keywords: Arrhythmia; Complication; Experience; Pacemaker; Pocket
Mesh:
Year: 2018 PMID: 29866050 PMCID: PMC5987385 DOI: 10.1186/s12872-018-0849-6
Source DB: PubMed Journal: BMC Cardiovasc Disord ISSN: 1471-2261 Impact factor: 2.298
Fig. 1Question 1 in the questionnaire. A higher score indicates worse outcome
Characteristics of 342 pacemaker patients
| Variable | n |
|---|---|
| Number of patients | 342 |
| Median age (years) | 77.6 (IQR 70.4–84.2) |
| Males | 195 (57.0%) |
| Pacemaker type | |
| DDD | 262 (76.6%) |
| VVI | 51 (14.9%) |
| AAI | 7 (2%) |
| CRT-P | 22 (6.4%) |
| Number of procedures | |
| 1 | 229 (67.0%) |
| 2 | 67 (19.6%) |
| 3 | 29 (8.5%) |
| 4 | 15 (4.4%) |
| 5 | 1 (0.3%) |
| 6 | 1 (0.3%) |
| Complications requiring reintervention | |
| Lead malfunction | 40 (11.7%) |
| Pocket correction | 10 (2.9%) |
| Perforation | 5 (1.5%) |
| Extraction | 9 (2.6%) |
| Exploration unipolar lead | 1 (0.3%) |
| Body-mass index (kg/m2) | |
| < 20 | 11 (3.3%) |
| 20–25 | 119 (35.7%) |
| 25–30 | 130 (39%) |
| > 30 | 73 (21.9%) |
Fig. 2Histogram of frequency and outcome of pacemaker-patient reporting on a 100 mm scale. A higher score indicates worse outcome
Percentile distribution and mean values (standard deviations) of responses on VAS-scale (mm)
| Question | 5% | 25% | 50% | 75% | 95% | Mean(SD) |
|---|---|---|---|---|---|---|
| Overall satisfaction | 0 | 2 | 5 | 13 | 44.9 | 10.3 (14.1) |
| Pain | 0 | 1 | 3 | 8 | 38 | 8.3 (13.1) |
| Soreness/discomfort | 0 | 2 | 4 | 14 | 62 | 13 (19.5) |
| Cosmetic results | 0 | 2 | 5 | 15.8 | 50.9 | 12.4 (17.9) |
| Movement | 0 | 1 | 4 | 10 | 53.9 | 10.3 (17.8) |
| Sleep | 0 | 2 | 4 | 9 | 44.8 | 9.2 (14.8) |
| Concern about malfunction | 0 | 2 | 4 | 13 | 52.9 | 11.7 (18.4) |
Median and interquartile range (IQR) with regard to sex and reoperation (p-value using Mann-Whitney U-test)
| Question | Females, median (IQR) | Males, median (IQR) | No reop, median (IQR) | Reoperation, median (IQR) | ||
|---|---|---|---|---|---|---|
| Overall satisfaction | 6 (3–15.5) | 5 (2–11.5) | 0.042 | 6 (2–14) | 4 (2–11) | 0.142 |
| Pain | 4 (2–11) | 3 (1–7) | 0.025 | 3 (2–9) | 3 (1–8) | 0.612 |
| Soreness/discomfort | 6 (2–20) | 4 (1–11) | 0.002 | 4 (2–14) | 5 (2–15) | 0.568 |
| Cosmetic results | 5 (2–17) | 4 (2–14) | 0.201 | 4 (2–13) | 7 (2–21) | 0.043 |
| Movement | 4 (2–13) | 3 (1–8) | 0.079 | 4 (1–10) | 3 (1–8) | 0.958 |
| Sleep | 5 (2–11.5) | 3 (1–7) | 0.009 | 4 (2–8) | 3 (1–9) | 0.595 |
| Concern about malfunction | 5 (2–13.5) | 4 (1–12) | 0.12 | 5 (2–13) | 3 (2–11) | 0.253 |