Double match of 18F-fluorodeoxyglucose-PET and iomazenil-SPECT improves outcomes of focus resection surgery.

Ayataka Fujimoto1, Tohru Okanishi2, Sotaro Kanai2, Keishiro Sato2, Shinji Itamura2, Shimpei Baba2, Mitsuyo Nishimura2, Takayuki Masui3, Hideo Enoki2.   

Abstract

BACKGROUND: When the results of electroencephalography (EEG), magnetic resonance imaging (MRI), and seizure semiology are discordant or no structural lesion is evident on MRI, single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are important examinations for lateralization or localization of epileptic regions. We hypothesized that the concordance between interictal 2-[18F]fluoro-2-deoxy-D-glucose (18FDG)-PET and iomazenil (IMZ)-SPECT could suggest the epileptogenic lobe in patients with non-lesional findings on MRI.
METHOD: Fifty-nine patients (31 females, 28 males; mean age, 29 years; median age, 27 years; range, 7-56 years) underwent subdural electrode implantation followed by focus resection. All patients underwent 18FDG-PET, IMZ-SPECT, and focus resection surgery. Follow-up was continued for ≥ 2 years. We evaluated surgical outcomes as seizure-free or not and analyzed correlations between outcomes and concordances of low-uptake lobes on PET, SPECT, or both PET and SPECT to the resection lobes. We used uni- and multivariate logistic regression analyses.
RESULTS: In univariate analyses, all three concordances correlated significantly with seizure-free outcomes (PET, p = 0.017; SPECT, p = 0.030; both PET and SPECT, p = 0.006). In multivariate analysis, concordance between resection and low-uptake lobes in both PET and SPECT correlated significantly with seizure-free outcomes (p = 0.004). The odds ratio was 6.0.
CONCLUSION: Concordance between interictal 18FDG-PET and IMZ-SPECT suggested that the epileptogenic lobe is six times better than each examination alone among patients with non-lesional findings on MRI. IMZ-SPECT and 18FDG-PET are complementary examinations in the assessment of localization-related epilepsy.

Entities:  

Keywords:  18FDG-PET; Complementary examination; Epilepsy surgery; IMZ-SPECT; Odds ratio

Mesh:

Substances:

Year:  2018        PMID: 29858947     DOI: 10.1007/s00701-018-3573-1

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  3 in total

1.  Refractory seizures: Prediction of outcome of surgical intervention based on results from PET-CT, PET-MRI and electroencephaolography.

Authors:  Rashad Johnson; Grace Rizk; Harleen Kaur; Henry Ibekwe; Monica Atta; Isis Gayed
Journal:  Neuroradiol J       Date:  2019-10-22

2.  Thai National Guideline for Nuclear Medicine Investigations in Epilepsy.

Authors:  Tawika Kaewchur; Wichana Chamroonrat; Tanyaluck Thientunyakit; Benjapa Khiewvan; Nantaporn Wongsurawat; Chanisa Chotipanich; Yotin Chinvarun; Krishnapundha Bunyaratavej; Sasithorn Amnuaywattakorn; Nucharee Poon-Iad; Tanawat Sontrapornpol; Panya Pasawang; Supatporn Tepmongkol
Journal:  Asia Ocean J Nucl Med Biol       Date:  2021

3.  Endovascular Electroencephalogram Records Simultaneous Subdural Electrode-Detectable, Scalp Electrode-Undetectable Interictal Epileptiform Discharges.

Authors:  Ayataka Fujimoto; Yuji Matsumaru; Yosuke Masuda; Aiki Marushima; Hisayuki Hosoo; Kota Araki; Eiichi Ishikawa
Journal:  Brain Sci       Date:  2022-02-24
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.