| Literature DB >> 29848357 |
Bo Li1, Pengfei Lei2, Hao Liu3, Xiaobin Tian1, Ting Wen2, Ruyin Hu4, Yihe Hu5.
Abstract
BACKGROUND: The conventional method of core decompression combined with porous bioceramics rod is usually performed under C-arm fluoroscopy for the treatment of early osteonecrosis of the femoral head (ONFH). This study was to evaluate the clinical value and efficacy of three-dimensional (3D) printing guide plate in the process of core decompression plus porous bioceramics rod for the treatment of early ONFH.Entities:
Keywords: Femur head necrosis
Mesh:
Year: 2018 PMID: 29848357 PMCID: PMC5977560 DOI: 10.1186/s13018-018-0812-3
Source DB: PubMed Journal: J Orthop Surg Res ISSN: 1749-799X Impact factor: 2.359
Fig. 1a–c Pre-operative X-ray and CT images of hip joint
Fig. 2a The pre-operative 3D CT reconstruction images. b A virtual guide pin path was established on the proximal femur model using MedCAD, making the path reach to the target region. c The guide pin path was established with the assistance of the corresponding guide pin guide plate, which was performed at the opposite side by the same method
Patient characteristics (n = 40, means ± SD)
| Experiment group ( | Control group ( | ||
|---|---|---|---|
| Age, years | 42.30 ± 9.20 | 39.70 ± 8.40 | 0.357 |
| Sex | 0.327 | ||
| Male | 11 | 14 | |
| Female | 9 | 6 | |
| BMI | 24.95 ± 2.59 | 24.47 ± 2.05 | 0.152 |
| Etiologic factors, number of hips (%) | 0.414 | ||
| Alcohol | 10 | 7 | |
| Steroids | 7 | 11 | |
| Idiopathic | 3 | 2 | |
| ARCO stage | 0.803 | ||
| I | 6 | 7 | |
| II | 8 | 6 | |
| IIIA | 6 | 7 | |
| Preoperative Harris Hip Score | 72.70 ± 3.81 | 70.40 ± 3.36 | 0.051 |
Surgical profiles in two groups
| Experiment group ( | Control group ( |
| |
|---|---|---|---|
| Surgery time, min | 29.93 ± 2.13 | 40.51 ± 2.24 | 0.001 |
| Intraoperative blood loss, ml | 18.04 ± 11.14 | 39.91 ± 13.03 | 0.001 |
| Fluoroscopy times | 0.92 ± 0.41 | 4.14 ± 0.73 | 0.001 |
Fig. 3a The post-operative lateral X-ray films. b The post-operative anterior-posterior X-ray films, which showed the good position of core decompression with porous bioceramics rod. c The guide pin path was established under the assistance of individualized 3D guide plate during the operation
Harris scores in two groups
| Preoperatively | 6 months postoperatively | 12 months postoperatively | 18 months postoperatively | |
|---|---|---|---|---|
| Experiment group ( | 72.70 ± 3.81 | 88.55 ± 1.47a,b | 91.80 ± 1.51a,b | 94.20 ± 0.95a,b |
| Control group ( | 70.40 ± 3.36 | 83.75 ± 2.23a | 89.65 ± 1.46a | 91.85 ± 0.99a |
| 0.051 | < 0.05 | < 0.05 | < 0.05 |
avs preoperative values, P < 0.05
bvs control group, P < 0.05