Literature DB >> 29844737

Cardiac Magnetic Resonance to Evaluate Percutaneous Pulmonary Valve Implantation in Children and Young Adults.

Cesar Gonzalez de Alba, Fernando Molina Berganza, John Brownlee, Muhammad Khan, Dilachew Adebo.   

Abstract

Experience with cardiac magnetic resonance to evaluate coronary arteries in children and young adult patients is limited. Because noninvasive imaging has advantages over coronary angiography, we compared the effectiveness of these techniques in patients who were being considered for percutaneous pulmonary valve implantation. We retrospectively reviewed the cases of 26 patients (mean age, 12.53 ± 4.85 yr; range, 5-25 yr), all of whom had previous right ventricular-to-pulmonary artery homografts. We studied T2-prepared whole-heart images for coronary anatomy, velocity-encoded cine images for ventricular morphology, and function- and time-resolved magnetic resonance angiographic findings. Cardiac catheterization studies included coronary angiography, balloon compression testing, right ventricular outflow tract, and pulmonary artery anatomy. Diagnostic-quality images were obtained in 24 patients (92%), 13 of whom were considered suitable candidates for valve implantation. Two patients (8%) had abnormal coronary artery anatomy that placed them at high risk of coronary artery compression during surgery. Twelve patients underwent successful valve implantation after cardiac magnetic resonance images and catheterization showed no increased risk of compression. We attempted valve implantation in one patient with unsuitable anatomy but ultimately placed a stent in the homograft. Magnetic resonance imaging of coronary arteries is an important noninvasive study that may identify patients who are at high risk of coronary artery compression during percutaneous pulmonary valve implantation, and it may reveal high-risk anatomic variants that can be missed during cardiac catheterization.

Entities:  

Keywords:  Child; constriction, pathologic/etiology; coronary vessel anomalies/diagnostic imaging; heart defects, congenital; heart valve prosthesis implantation/diagnostic imaging; magnetic resonance imaging; predictive value of tests; pulmonary valve insufficiency/diagnosis; retrospective studies; ventricular outflow obstruction/therapy

Mesh:

Year:  2018        PMID: 29844737      PMCID: PMC5940288          DOI: 10.14503/THIJ-16-6100

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  26 in total

Review 1.  Clinical applications of cardiac magnetic resonance imaging after repair of tetralogy of Fallot.

Authors:  W A Helbing; A de Roos
Journal:  Pediatr Cardiol       Date:  2000 Jan-Feb       Impact factor: 1.655

Review 2.  T1 Mapping: Basic Techniques and Clinical Applications.

Authors:  Andrew J Taylor; Michael Salerno; Rohan Dharmakumar; Michael Jerosch-Herold
Journal:  JACC Cardiovasc Imaging       Date:  2016-01

Review 3.  Contribution of cardiovascular magnetic resonance in the evaluation of coronary arteries.

Authors:  Sophie Mavrogeni; George Markousis-Mavrogenis; Genovefa Kolovou
Journal:  World J Cardiol       Date:  2014-10-26

4.  Coronary artery imaging in grown up congenital heart disease: complementary role of magnetic resonance and x-ray coronary angiography.

Authors:  A M Taylor; S A Thorne; M B Rubens; P Jhooti; J Keegan; P D Gatehouse; F Wiesmann; F Grothues; J Somerville; D J Pennell
Journal:  Circulation       Date:  2000-04-11       Impact factor: 29.690

Review 5.  Cardiovascular MR imaging in neonates and infants with congenital heart disease.

Authors:  Christian J Kellenberger; Shi-Joon Yoo; Emanuela R Valsangiacomo Büchel
Journal:  Radiographics       Date:  2007 Jan-Feb       Impact factor: 5.333

6.  Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: comparison with x-ray angiography.

Authors:  Tal Geva; Gerald F Greil; Audrey C Marshall; Michael Landzberg; Andrew J Powell
Journal:  Circulation       Date:  2002-07-23       Impact factor: 29.690

7.  Risk of coronary artery compression among patients referred for transcatheter pulmonary valve implantation: a multicenter experience.

Authors:  Brian H Morray; Doff B McElhinney; John P Cheatham; Evan M Zahn; Darren P Berman; Patrick M Sullivan; James E Lock; Thomas K Jones
Journal:  Circ Cardiovasc Interv       Date:  2013-09-24       Impact factor: 6.546

8.  Identification of anomalous coronary arteries and their anatomic course by magnetic resonance coronary angiography.

Authors:  M V McConnell; P Ganz; A P Selwyn; W Li; R R Edelman; W J Manning
Journal:  Circulation       Date:  1995-12-01       Impact factor: 29.690

Review 9.  The role of cardiovascular magnetic resonance in pediatric congenital heart disease.

Authors:  Hopewell N Ntsinjana; Marina L Hughes; Andrew M Taylor
Journal:  J Cardiovasc Magn Reson       Date:  2011-09-21       Impact factor: 5.364

Review 10.  Normal values for cardiovascular magnetic resonance in adults and children.

Authors:  Nadine Kawel-Boehm; Alicia Maceira; Emanuela R Valsangiacomo-Buechel; Jens Vogel-Claussen; Evrim B Turkbey; Rupert Williams; Sven Plein; Michael Tee; John Eng; David A Bluemke
Journal:  J Cardiovasc Magn Reson       Date:  2015-04-18       Impact factor: 5.364

View more
  1 in total

1.  Preclinical study of a self-expanding pulmonary valve for the treatment of pulmonary valve disease.

Authors:  Dajun Kuang; Yang Lei; Li Yang; Yunbing Wang
Journal:  Regen Biomater       Date:  2020-08-22
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.