Literature DB >> 29794696

Motiva Ergonomix Round SilkSurface Silicone Breast Implants: Outcome Analysis of 100 Primary Breast Augmentations over 3 Years and Technical Considerations.

Georg M Huemer1,2, Raphael Wenny1,2, Matthias M Aitzetmüller1,2, Dominik Duscher1,2.   

Abstract

BACKGROUND: Macrotextured anatomical implants are frequently used in aesthetic breast surgery; however, several safety concerns linked to this implant type have been raised recently. In an attempt to address these shortcomings, Motiva Ergonomix implants have been introduced. Here, the authors describe the current world's largest experience with these novel devices in aesthetic breast surgery and evaluate the postoperative outcome of 100 primary breast augmentations.
METHODS: A retrospective assessment of 100 consecutive primary breast augmentation patients over a period of 3 years was conducted. Patients were followed for a minimum of 6 months postoperatively. Demographics, surgical data, and complications were recorded. In addition, a survey regarding the breast augmentation outcome was performed.
RESULTS: The reasons for surgery were mainly hypoplasia (52 percent) and ptosis (28 percent). All implants were placed by means of an inframammary approach in a submuscular pocket, and the average implant volume was 370 cc (range, 150 to 700 cc) with mostly full projection (65 percent). The revision rate was 7 percent. The authors observed four cases of implant malpositioning, one implant rupture, one implant exchange for aesthetic reasons, and one hematoma evacuation. Nevertheless, the authors achieved a 100 percent satisfaction rate with the postsurgical outcome among both patients and surgeons.
CONCLUSIONS: Motiva Ergonomix implants provide reliable and satisfying results for both patients and surgeons. They can be used safely and effectively for aesthetic breast surgery. However, like all breast prostheses, Motiva Ergonomix implants are not completely free of complications and should be used only with advanced technique to achieve optimal results. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29794696     DOI: 10.1097/PRS.0000000000004367

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  6 in total

1.  The Prepectoral, Hybrid Breast Reconstruction: The Synergy of Lipofilling and Breast Implants.

Authors:  Filip B J L Stillaert; Bernd Lannau; Koenraad Van Landuyt; Phillip N Blondeel
Journal:  Plast Reconstr Surg Glob Open       Date:  2020-07-23

2.  Four-Year Interim Results of the Safety of Augmentation Mammaplasty Using the Motiva Ergonomix™ Round SilkSurface: A Multicenter, Retrospective Study.

Authors:  Pa Hong; Seung Soo Kim; Cheol Jeong; Seung Hwan Hwang; Tae Seob Kim; Jung Heum Park; Yun Gyu Song; Yu Kwan Song
Journal:  Aesthetic Plast Surg       Date:  2021-03-01       Impact factor: 2.708

Review 3.  A Shakespearean Dilemma in Breast Augmentation: to Use Drains or not? a Systematic Review : Drains in Breast Augmentation.

Authors:  Matteo Torresetti; Yasmine Zavalloni; Benedetta Peltristo; Giovanni Di Benedetto
Journal:  Aesthetic Plast Surg       Date:  2022-01-20       Impact factor: 2.708

4.  Nanotextured Breast Implants: Not a Solution for All Seasons.

Authors:  Maurizio Bruno Nava; Giuseppe Catanuto; Nicola Rocco
Journal:  Aesthet Surg J       Date:  2021-03-12       Impact factor: 4.283

5.  High-Resolution Ultrasound-Assisted Assessment of Preliminary Short-term Safety Outcomes of an Implant-Based Augmentation Mammaplasty Using a Bioengineered, Cell-Friendly, Smooth-Surface Device in Korean Females.

Authors:  Sangdal Lee; Jeong Pil Jeong; Jung Youp Sung; Woo Sik Choi; Dong Seung Moon; Ho Chan Kim; Jae Hong Kim
Journal:  Aesthet Surg J Open Forum       Date:  2021-11-09

6.  Nano-Surface Implants: Indications and Limitations.

Authors:  Moustapha Hamdi
Journal:  Aesthet Surg J       Date:  2021-07-14       Impact factor: 4.283

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.