Literature DB >> 29788263

Temporal course of vascular healing and neoatherosclerosis after implantation of durable- or biodegradable-polymer drug-eluting stents.

Giulio Guagliumi1, Kunihiro Shimamura2, Vasile Sirbu1, Roberto Garbo3, Giacomo Boccuzzi3, Angelina Vassileva1, Orazio Valsecchi1, Luigi Fiocca1, Paolo Canova1, Francesco Colombo3, Gabriel Tensol Rodriguez Pereira4, Daisuke Nakamura4, Guilherme F Attizzani4, Alberto Cereda1, Keisuke Satogami2, Leonardo De Luca5, Francesco Saia6, Davide Capodanno7.   

Abstract

Aims: Delayed healing and endothelial dysfunction may occur with drug-eluting stents (DES), promoting accelerated infiltration of lipids in the neointima and development of neoatherosclerosis (NA). Pathology data suggest durable polymer (DP) of DES to play a major role in this process. Whether biodegradable polymer (BP) may address these issues is uncertain. We compared in vivo vessel healing and NA of current generation BP- or DP-DES using serial optical coherence tomography (OCT) assessments. Methods and results: Ninety patients with multivessel coronary artery disease were randomized 1:1 to BP everolimus-eluting stents (EES, Synergy) or DP zotarolimus-eluting stents (ZES, Resolute Integrity). Co-primary endpoints were the maximum length of uncovered struts at 3 months (powered for non-inferiority) and the percentage of patients presenting with frames of NA at 18 months (powered for superiority) as measured by OCT. The maximum length of uncovered struts at 3 months was 10 ± 8 mm in the BP-EES group and 11 ± 7 mm in the DP-ZES group (mean difference -1 mm; upper 97.5% confidence interval +2 mm; P = 0.05 for non-inferiority; P = 0.45 for superiority). The percentage of patients presenting with frames of NA at 18 months was low and similar between BP-EES and DP-ZES groups (11.6% vs. 15.9%; P = 0.56). There was no stent thrombosis in both groups at 24 months.
Conclusion: BP-EES and DP-ZES showed a similar healing response at 3 months and a low incidence of NA at 18 months. Biocompatible polymers, regardless of whether they are durable or biodegradable, may favourably impact the long-term vascular response to current-generation DES.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29788263     DOI: 10.1093/eurheartj/ehy273

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  11 in total

1.  The year in cardiology 2018: coronary interventions.

Authors:  Dariusz Dudek; Artur Dziewierz; Gregg Stone; William Wijns
Journal:  Eur Heart J       Date:  2019-01-07       Impact factor: 29.983

Review 2.  Drug-eluting coronary stents: insights from preclinical and pathology studies.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Matthew Kutyna; Anne Cornelissen; Salome Kuntz; Liang Guo; Hiroyoshi Mori; Emanuel Harari; Ka Hyun Paek; Raquel Fernandez; Diljon Chahal; Maria E Romero; Frank D Kolodgie; Anuj Gupta; Renu Virmani; Aloke V Finn
Journal:  Nat Rev Cardiol       Date:  2019-07-25       Impact factor: 32.419

Review 3.  Advances in mammalian target of rapamycin kinase inhibitors: application to devices used in the treatment of coronary artery disease.

Authors:  Hiroyuki Jinnouchi; Liang Guo; Atsushi Sakamoto; Yu Sato; Anne Cornelissen; Rika Kawakami; Masayuki Mori; Sho Torii; Salome Kuntz; Emanuel Harari; Hiroyoshi Mori; Daniela Fuller; Neel Gadhoke; Raquel Fernandez; Ka Hyun Paek; Dipti Surve; Maria Romero; Frank D Kolodgie; Renu Virmani; Aloke V Finn
Journal:  Future Med Chem       Date:  2020-05-20       Impact factor: 3.808

4.  Vascular responses to coronary calcification following implantation of newer-generation drug-eluting stents in humans: impact on healing.

Authors:  Sho Torii; Hiroyuki Jinnouchi; Atsushi Sakamoto; Hiroyoshi Mori; Joohyung Park; Falone C Amoa; Mariem Sawan; Yu Sato; Anne Cornelissen; Salome H Kuntz; Matthew Kutyna; Ka Hyun Paek; Raquel Fernandez; Ryan Braumann; Eric K Mont; Dipti Surve; Maria E Romero; Frank D Kolodgie; Renu Virmani; Aloke V Finn
Journal:  Eur Heart J       Date:  2020-02-01       Impact factor: 29.983

5.  Early vascular healing of ultra-thin strut polymer-free sirolimus-eluting stents in acute coronary syndrome: USUI-ACS study.

Authors:  Yutaka Matsuhiro; Yasuyuki Egami; Naotaka Okamoto; Masaya Kusuda; Takashige Sakio; Hiroaki Nohara; Hiroki Sugae; Shodai Kawanami; Akito Kawamura; Kohei Ukita; Hitoshi Nakamura; Koji Yasumoto; Masaki Tsuda; Yasuharu Matsunaga-Lee; Masamichi Yano; Masami Nishino; Jun Tanouchi
Journal:  Cardiovasc Interv Ther       Date:  2022-04-27

6.  Deep neural networks for A-line-based plaque classification in coronary intravascular optical coherence tomography images.

Authors:  Chaitanya Kolluru; David Prabhu; Yazan Gharaibeh; Hiram Bezerra; Giulio Guagliumi; David Wilson
Journal:  J Med Imaging (Bellingham)       Date:  2018-12-03

Review 7.  Drug-eluting balloon: is it useful?

Authors:  Sidhi Laksono; Budhi Setianto; Steven Philip Surya
Journal:  Egypt Heart J       Date:  2020-11-11

Review 8.  Inflammation as a determinant of healing response after coronary stent implantation.

Authors:  Dorota Ochijewicz; Mariusz Tomaniak; Grzegorz Opolski; Janusz Kochman
Journal:  Int J Cardiovasc Imaging       Date:  2021-01-21       Impact factor: 2.357

9.  Long-Term Clinical Outcomes Between Biodegradable and Durable Polymer Drug-Eluting Stents: A Nationwide Cohort Study.

Authors:  Seung-Jun Lee; Dong-Woo Choi; Yongsung Suh; Sung-Jin Hong; Chul-Min Ahn; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Eun-Cheol Park; Yangsoo Jang; Chung-Mo Nam; Myeong-Ki Hong
Journal:  Front Cardiovasc Med       Date:  2022-04-29

10.  Comparison of 6-month vascular healing response after bioresorbable polymer versus durable polymer drug-eluting stent implantation in patients with acute coronary syndromes: A randomized serial optical coherence tomography study.

Authors:  Masahiko Noguchi; Tomotaka Dohi; Shinya Okazaki; Mitsuaki Matsumura; Mitsuhiro Takeuchi; Hirohisa Endo; Yoshiteru Kato; Iwao Okai; Hiroki Nishiyama; Shinichiro Doi; Hiroshi Iwata; Kikuo Isoda; Eisuke Usui; Tatsuhiro Fujimura; Fumiyasu Seike; Gary S Mintz; Katsumi Miyauchi; Hiroyuki Daida; Tohru Minamino; Akiko Maehara
Journal:  Catheter Cardiovasc Interv       Date:  2021-08-06       Impact factor: 2.585

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.