Literature DB >> 29774592

Risk factors for stroke on left ventricular assist devices.

Muath Bishawi1,2, Jeremy Joseph1, Chetan Patel3, Jacob Schroder1, Mani Daneshmand1, Dawn Bowles4, Joseph Rogers3, Carmelo Milano1.   

Abstract

BACKGROUND: Patients with end-stage heart failure on left ventricular assist devices (LVADs) are predisposed to a high incidence of stroke. Preoperative factors associated with increased stroke risk are poorly understood.
METHODS: We performed a single-center retrospective review of all patients from 2009 to 2014 in whom a rotary flow LVAD was implanted. All patients with symptoms of a cerebrovascular event underwent a non-contrast head computed tomography scan. Logistic regression was used to determine factors associated with stroke both on univariate and multivariable analysis.
RESULTS: A total of 390 patients were retrospectively analyzed and of those 61 (15.6%) had a stroke at an average follow-up of 3.5 ± 1.6 years. The majority were male (72%) and were treated a priori as destination therapy (73%). The proportion of patient receiving a centrifugal flow pump was 23% compared to 77% receiving an axial flow pump. For those patients who experienced a stroke and then died, the average time from stroke to death was 158 ± 296 days. Of the 61 patients who had a stroke, 38 (62%) died (P < 0.001 compared to death rate without a stroke). On Cox regression analysis, a history of cerebrovascular accident (CVA), hyperlipidemia, and history of venous thromboembolism (VTE) were independently associated with stroke while on LVAD support.
CONCLUSION: Postoperative stroke after LVAD implantation was associated with higher mortality. A history of previous CVA, VTE, and hyperlipidemia were independently associated with stroke while on LVAD support.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  LVAD; risk factors; stroke

Mesh:

Year:  2018        PMID: 29774592     DOI: 10.1111/jocs.13718

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  4 in total

1.  Incidence and Diagnostic Challenges of Bowel Ischemia after Continuous-flow Left Ventricular Assist Device Therapy.

Authors:  Ashley Y Choi; Jatin Anand; Muath Bishawi; Samantha E Halpern; Fabian J Contreras; Michelle A Mendiola; Mani A Daneshmand; Jacob N Schroder; Cory Vatsaas; Suresh M Agarwal; Carmelo A Milano
Journal:  ASAIO J       Date:  2021-08-20       Impact factor: 3.826

2.  Decompressive hemicraniectomy for acute ischemic stroke in a patient implanted with a left ventricular assist device: a case report.

Authors:  Walid Oulehri; Mircea Cristinar; Gharib Ajob; Sandrine Marguerite; Bob Heger; Hélène Cebula; Michel Kindo; Paul Michel Mertes
Journal:  BMC Cardiovasc Disord       Date:  2020-06-10       Impact factor: 2.298

3.  Bridge from central extracorporeal life support is a risk factor of cerebrovascular accidents after durable left ventricular assist device implantation.

Authors:  Kohei Tonai; Satsuki Fukushima; Naoki Tadokoro; Satoshi Kainuma; Naonori Kawamoto; Takashi Kakuta; Ayumi Koga-Ikuta; Takuya Watanabe; Osamu Seguchi; Yasumasa Tsukamoto; Norihide Fukushima; Tomoyuki Fujita
Journal:  J Artif Organs       Date:  2021-12-06       Impact factor: 1.385

4.  Inflow cannula position as risk factor for stroke in patients with HeartMate 3 left ventricular assist devices.

Authors:  Thomas Schlöglhofer; Philipp Aigner; Marcel Migas; Dietrich Beitzke; Kamen Dimitrov; Franziska Wittmann; Julia Riebandt; Marcus Granegger; Dominik Wiedemann; Günther Laufer; Francesco Moscato; Heinrich Schima; Daniel Zimpfer
Journal:  Artif Organs       Date:  2022-01-09       Impact factor: 2.663

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.