Imran Niazi1, James Baker2, Raffaele Corbisiero3, Charles Love4, David Martin5, Robert Sheppard6, Seth J Worley7, Niraj Varma8, Kwangdeok Lee9, Gery Tomassoni10. 1. Aurora Cardiovascular Services, Aurora Sinai/Aurora St Luke's Medical Centers, Milwaukee, Wisconsin. Electronic address: publishing24@aurora.org. 2. Saint Thomas Research Institute, Nashville, Tennessee. 3. Deborah Heart and Lung, Browns Mills, New Jersey. 4. NYU Langone Medical Center, New York, New York. 5. Lahey Hospital and Medical Center - Cardiology, Burlington, Massachusetts. 6. The Heart Institute, St. Petersburg, Florida. 7. Lancaster Heart Foundation, Lancaster, Pennsylvania. 8. Cleveland Clinic, Cleveland, Ohio. 9. Abbott, Plano, Texas. 10. Lexington Cardiology at Central Baptist, Lexington, Kentucky.
Abstract
OBJECTIVES: The MultiPoint Pacing (MPP) trial assessed the safety and efficacy of pacing 2 left ventricular sites with a quadripolar lead in patients with heart failure indicated for a CRT-D device. BACKGROUND: Cardiac resynchronization therapy nonresponse is a complex problem where stimulation of multiple left ventricular sites may be a solution. METHODS: Enrolled patients were indicated for a CRT-D system. Bi-ventricular (Bi-V) pacing was activated at implant. Three months later, clinical response was assessed and the patient was randomized (1:1) to receive Bi-V pacing or MPP. Patients were followed for 6 months post-randomization and clinical response was again assessed. RESULTS: The CRT-D system was successfully implanted in 455 of 469 attempted implants (97%). A total of 381 patients were randomized to Bi-V or MPP at 3 months. The primary safety endpoint was met with freedom from system-related complications of 93.2%. The primary efficacy endpoint of the noninferiority comparison of nonresponder rates between the 2 arms was met. Patients randomized to MPP arm and programmed to pace from anatomically distant poles (MPP-AS) responded to therapy at significantly higher rates than MultiPoint pacing-other programmed settings (MPP-Other). Within this group, 87% were responders at 9 months, 100% designated as nonresponders at 3 months converted to responders at 9 months, and 54% experienced an incremental response compared to MPP-Other. Also within MPP-AS, 92% of patients with de novo CRT-D implant were classified as responders compared with patients with MPP-Other. CONCLUSIONS:MPP is safe and effective for treating heart failure. The study met the pre-specified hypothesis that response to MPP is noninferior to Bi-V pacing with a quadripolar left ventricular lead. (MultiPoint Pacing IDE Study [MPP IDE]; NCT01786993).
RCT Entities:
OBJECTIVES: The MultiPoint Pacing (MPP) trial assessed the safety and efficacy of pacing 2 left ventricular sites with a quadripolar lead in patients with heart failure indicated for a CRT-D device. BACKGROUND: Cardiac resynchronization therapy nonresponse is a complex problem where stimulation of multiple left ventricular sites may be a solution. METHODS: Enrolled patients were indicated for a CRT-D system. Bi-ventricular (Bi-V) pacing was activated at implant. Three months later, clinical response was assessed and the patient was randomized (1:1) to receive Bi-V pacing or MPP. Patients were followed for 6 months post-randomization and clinical response was again assessed. RESULTS: The CRT-D system was successfully implanted in 455 of 469 attempted implants (97%). A total of 381 patients were randomized to Bi-V or MPP at 3 months. The primary safety endpoint was met with freedom from system-related complications of 93.2%. The primary efficacy endpoint of the noninferiority comparison of nonresponder rates between the 2 arms was met. Patients randomized to MPP arm and programmed to pace from anatomically distant poles (MPP-AS) responded to therapy at significantly higher rates than MultiPoint pacing-other programmed settings (MPP-Other). Within this group, 87% were responders at 9 months, 100% designated as nonresponders at 3 months converted to responders at 9 months, and 54% experienced an incremental response compared to MPP-Other. Also within MPP-AS, 92% of patients with de novo CRT-D implant were classified as responders compared with patients with MPP-Other. CONCLUSIONS:MPP is safe and effective for treating heart failure. The study met the pre-specified hypothesis that response to MPP is noninferior to Bi-V pacing with a quadripolar left ventricular lead. (MultiPoint Pacing IDE Study [MPPIDE]; NCT01786993).