Literature DB >> 29757205

Label-Free G-Quadruplex Aptamer Fluorescence Assay for Ochratoxin A Using a Thioflavin T Probe.

Kefeng Wu1, Changbei Ma2, Han Zhao3, Hailun He4, Hanchun Chen5.   

Abstract

Ochratoxin A (OTA) is one of the most common mycotoxins contaminating feed and foodstuffs. Therefore, a great deal of concern is associated with AFB1 toxicity. In this work, a fast and sensitive fluorescence aptamer biosensor has been proposed for the OTA assay. In the absence of OTA, the OTA aptamer can form a G-quadruplex structure with thioflavin T (ThT) dye, which results in increased fluorescence. After joining OTA, OTA aptamer combines with OTA and the G-quadruplex can be formed. Only faint fluorescence was finally observed when ThT weakly reacts with the quadruplex. Through this test method, the entire reaction and analysis process of OTA can be completed in 10 min. Under optimal experimental conditions (600 nM OTA-APT, 7 μM ThT, and 3 min incubation time), this proposed assay has a good limit of detection (LOD) of 0.4 ng/mL and shows a good linear relationship within the range of 1.2⁻200 ng/mL under the best experimental conditions. This method has a high specificity for OTA relative to Ochratoxin B (23%) and Aflatoxin B₁ (13%). In addition, the quantitative determination of this method in real samples has been validated using a sample of red wine supplemented with a range of OTA concentrations (1.2 ng/mL, 12 ng/mL, and 40 ng/mL) with recoveries of 96.5% to 107%.

Entities:  

Keywords:  G-quadruplex aptamer; fluorescence assay; ochratoxin A; thioflavin T

Mesh:

Substances:

Year:  2018        PMID: 29757205      PMCID: PMC5983254          DOI: 10.3390/toxins10050198

Source DB:  PubMed          Journal:  Toxins (Basel)        ISSN: 2072-6651            Impact factor:   4.546


1. Introduction

Ochratoxin A (OTA) is a well-known mycotoxin produced by various Aspergillus and Penicillium strains and found in many foods such as cereals, coffee, cocoa, dried fruit, wine and grape juice, beer, spices, meat, and meat products [1,2,3,4,5,6]. OTA has a broad range of toxicological effects on animals and humans including neurotoxicity, immunotoxicity, teratogenicity, reproductive toxicity, and carcinogenicity [7,8,9,10]. OTA is easy to absorb and slowly decomposes. In the body, OTA metabolizes very slowly with a half-life of more than 30 days. Unlike other toxins, OTA is resistant to both low and high temperatures [11,12,13]. Humans absorb OTA mainly from moldy agricultural products and spoiled foods. Research reveals that this toxin can cause a wide range of health problems [14,15]. International and government agencies in many countries manage OTA content in food. Therefore, ensuring food safety and eliminating the potential risks posed by OTA is of great significance and it is necessary for developing an efficient and fast method for OTA monitoring. The conventional methods for OTA analysis include Thin Layer Chromatography (TLC), High Performance Liquid Chromatography (HPLC), Gas Chromatography (GC), and Mass Spectrometry (MS) [16,17,18]. Although these methods have shown successful results for OTA detection, they involve expensive and laborious sample preparation steps. In order to overcome these problems, some recent testing methods have been developed. Chen et al. developed a simple and rapid biosensor for OTA based on a structure-switching signaling aptamer [19]. Lei et al. demonstrated a signal amplification strategy based on nuclease-aided target recycling for OTA detection [20]. Jo et al. presented the detection of OTA in coffee using chemiluminescence [21]. However, in these strategies, the aptamer needs to be labeled with fluorophores. Aptamers are single-stranded nucleic acids or peptide molecules exhibiting unique secondary structures, which can bind specifically to their targets. Aptamers can be used for the detection of small molecules, proteins, nucleic acids, cells, tissues, and organisms. Furthermore, aptamers perform better in synthesis, maintenance, and delivery, which demonstrate the ability of aptamers to be promising molecular receptors for bioanalytical applications [22,23,24,25,26]. Recently, a series of aptamer-based methods for detecting OTA has been reported. These assays mainly include fluorescence [27,28], electrochemical assays [29,30], colorimetric analysis [31,32,33], nanomaterials [34,35], and photoelectrochemical immunosensors [36]. Thioflavin T (ThT), which is a commercially available water-soluble fluorogenic dye, has been demonstrated to selectively bind to G-quadruplexes. This results in a significant enhancement of fluorescence. This finding has led to the development of G-quadruplex-based fluorescent sensors. However, the exploration of ThT is still at an early stage and has a great potential to be utilized in biochemical and biomedical applications. In this present study, we, for the first time, prepared a label-free fluorescence aptasensor for OTA determination based on ThT/G-quadruplex [37,38,39,40,41,42]. This proposed fluorescent assay is rapid, easy to operate, and can be applied to detect OTA in red wine.

2. Results and Discussion

2.1. Aptasensor Principles

In this study, a fast fluorescence aptasensor for ochratoxin A determination was proposed and the design principle is illustrated in Scheme 1. The OTA-APT probe is the aptamer of OTA. In the absence of OTA, OTA-APT can form a ThT/G-quadruplex complex with ThT, which result in increased fluorescence. After joining OTA, the OTA aptamer combines with OTA and forms the antiparallel G-quadruplex. Due to a weak reaction between ThT and G-quadruplex, only faint fluorescence was observed. According to the change of a fluorescence signal from the detection system, we can easily detect OTA concentration.
Scheme 1

Schematic illustration of the fluorescent aptamer sensor for OTA. In the absence of OTA, OTA-Aptamer can form a G-quadruplex structure with thioflavin T (ThT), which results in enhanced fluorescence. After addition of OTA, OTA-Aptamer specifically binds to OTA and forms the G-quadruplex. After this quadruplex has a weak reaction with ThT, weak fluorescence is observed.

2.2. Feasibility Test

To demonstrate the feasibility of our method, two samples were prepared. Sample A contains the OTA-APT probe only. Sample B contains the OTA-APT probe and OTA. Figure 1 shows the fluorescence emission spectra of the OTA-APT probe both in the absence (curves A) and presence (curves B) of OTA. As demonstrated in Figure 1, the fluorescence emission intensity was quite low in the presence of OTA (curve B). This was expected since in the presence of OTA, the OTA aptamer combines with OTA and the antiparallel G-quadruplex structure can be formed. As shown in curve A, the OTA aptamer can form the G-quadruplex structure with ThT dye in the absence of OTA, which results in an increase in the fluorescent signal. This method established a simple but effective strategy for OTA concentration detection.
Figure 1

Fluorescence emission spectra in the (A) absence and (B) presence of OTA.

2.3. Optimization of the Aptameric Sensing Experiment

In order to obtain a desirable fluorescence response, experimental conditions were optimized including the concentration of OTA–APT, the concentration of ThT, and the reaction time. As shown in Figure 2A, the fluorescence signal enhancement was strongly dependent on the concentration of OTA-APT with the optimal concentration achieved at 600 nM. As shown in Figure 2B, the ratio of the increase in fluorescence intensity reached a plateau at 7 μM of ThT. Therefore, the optimized concentration of ThT was 7 μM in this detection method. As shown in Figure 2C, the incubation time of OTA and OTA-APT was optimized. The result showed that the ratio of increase in fluorescence intensity almost reached a plateau within three minutes. Therefore, we chose three minutes as the OTA incubation time.
Figure 2

Optimization of OTA experimental conditions: (A) concentration of OTA-APT probe, (B) concentration of ThT, and (C) reaction time. F0 and F represent the fluorescence intensities in the absence and presence of OTA, respectively. Error bars are standard deviations of three experiments.

2.4. Quantitative Detection of OTA

Under the optimized conditions, OTA was sensitively and quantitatively detected using the proposed aptasensor strategy. As depicted in Figure 3A, the fluorescence intensity of the system gradually decreased with increasing OTA concentrations in the range of 0–360 ng/mL. A calibration curve of fluorescence intensity as a function of concentration was plotted (see Figure 3B). This revealed that there was a sufficient linear correlation with a correlation coefficient of 0.99 between the fluorescence intensity and the OTA concentration in the range of 1.2–200 ng/mL (see Figure 3B). The limit of detection (LOD) was calculated to be 0.4 ng/mL according to the 3σ rule. As shown in Table 1, the OTA detection performance of our method was comparable to what was reported in most of the other studies. Therefore, it can be concluded that our assay technique may provide a simple and fast method for the sensitive quantification of OTA.
Figure 3

(A) Fluorescent signal response with different concentrations of OTA. OTA concentration decreased from bottom to top: 360, 280, 200, 120, 40, 12, 1.2, 0.4, and 0 ng/mL, (B) OTA assay showing the linear curve of the enhanced fluorescence intensity to concentration of OTA. The inset shows the linearity of the fluorescence intensity respect to OTA concentrations. Error bars are standard deviations of three experiments.

Table 1

Comparison with the current reported methods for OTA Determination.

MethodDetection Limit (ng/mL)Linear Range (ng/mL)Ref
Gold nanoparticle88–250[32]
Gold nanorod0.220.5–22[35]
Carbon nanotube44–80[20]
Double label 0.81–100[19]
SYBR Green I44–40[27]
CRET0.220.1–100[21]
Label-free0.41.2–200This work

2.5. Selectivity of OTA Assay

The specificity of the method was tested using OTB and AFB1. The experiments were performed using 200 ng/mL of OTA, 360 ng/mL of OTB, and 360 ng/mL of AFB1, respectively. It is clear from Figure 4 that only OTA can induce a remarkable signal attributed to the inherent specificity of the aptamer towards OTA. OTB and AFB1 resulted in only negligible fluorescent signal changes. The results demonstrate that the method has good selectivity.
Figure 4

Selectivity of the proposed OTA (200 ng/mL) assay towards OTB and Aflatoxin B1 (360 ng/mL, respectively). Error bars are standard deviations of three experiments.

2.6. Determination of OTA in Practical Samples

In order to test the feasibility and accuracy of the developed method, recovery tests were made in red wine samples. The aptasensor was used for determining the recoveries of three different concentrations of OTA (1.2 ng/mL, 12 ng/mL, and 40 ng/mL). The recoveries were found to vary in 96.5% to 107% (see Table 2), which confirmed the satisfactory accuracy of the assay for target OTA in a complicated sample matrix.
Table 2

Application of aptasensor for OTA determination in red wine.

Sample NumberAdded (ng/mL)Detected (ng/mL)Recovery (%)
11.21.28 ± 0.11107
21213.4 ± 0.25111.6
34038.6 ± 0.5396.5

3. Conclusions

A fluorescence aptasensor was designed for fast detection of OTA based on ThT/G-quadruplex. Under the optimized conditions, this aptasensor exhibited a low detection limit of 0.4 ng/mL and a linear range of 1.2 ng/mL to 200 ng/mL for OTA. This detection method avoids the complicated synthesis and modification of sensing probes, which significantly lowered the detection cost. Furthermore, the aptasensor can be applied to the quantitative determination of OTA in real samples with satisfactory results. This strategy shows high sensitivity, good selectivity, and offers a wide range of applications in food safety-related fields. Moreover, this sensing strategy has the potential to be applied to other aptamer-based biochemical assays for the detection of small molecules in the fields of environmental monitoring and medical diagnostics.

4. Experimental

4.1. Materials and Measurements

Ochratoxin A (OTA) and ochratoxin B (OTB) were purchased from Pribolab Co., Ltd. (Qingdao, China). Aflatoxin B1 (AFB1) was purchased from Yuanye Co., Ltd. (Shanghai, China). The DNA probe (OTA-APT) was purchased from Sangon Biotechnology Co., Ltd. (Shanghai, China). Tris [Tris-(hydroxy-methyl)aminomethane], hydrochloric acid (HCl), potassium chloride (KCl), sodium chloride (NaCl), and calcium chloride (CaCl2) were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Thioflavin T (ThT) was purchased from Sigma-Aldrich (St. Louis, MO, USA). All other reagents were of analytical reagent grade and were used as received. Ultra-pure water (18.2 MΩ·cm−1) was used in all experiments. The DNA probe was dissolved in the Tris-EDTA buffer and stored at −20 °C until further use. OTA-APT sequences were marked by 5′-GATCGGGTGTGGGTGGCGTAAAGGGAGCATCGGACA-3′. The fluorescence spectra were obtained using a Hitachi F-2700 fluorescence spectrophotometer (Hitachi Ltd., Tokyo, Japan). The samples placed in quartz cuvettes were excited at a wavelength of 425 nm and all emission spectra were collected at wavelengths of 450–600 nm at room temperature.

4.2. Optimization of Experimental Conditions

In order to obtain the best experimental results, the relevant experimental conditions were optimized one by one including the concentrations of OTA-APT, the concentrations of ThT, and the reaction time. The concentration range of OTA-APT was 100 nM, 200 nM, 400 nM, 600 nM, and 800 nM. The ThT concentration was 1 μM, 3 μM, 5 μM, 7 μM, and 10 μM. The reaction time was 1 min, 2 min, 3 min, 5 min, and 10 min.

4.3. Aptamer Biosensor for Detecting OTA

For a typical OTA fluorescence aptasensor experiment, the OTA buffer (containing 10 mM Tris-HCl, 120 mM NaCl, 20 mM CaCl2, 5 mM KCl, pH = 8.5), 600 nM OTA-APT and different concentrations of OTA were incubated at room temperature for 3 min. Afterward, 7 μM ThT was added to the reaction solution. After 5 min, fluorescence intensity was measured with excitation at 425 nm and the emission spectra were collected in the range of 450–600 nm. All reactions were conducted at a final reaction volume of 100 μL for three times.

4.4. Selectivity Assay

In order to analyze the specificity of this experiment for OTA, we chose OTB and AFB1 as controls. At first, OTA buffer, 600 nM OTA-APT and 200 ng/mL OTA, and 360 ng/mL OTB and 360 ng/mL AFB1 were incubated at room temperature for 3 min. Following this, 7 μM ThT was added. After 5 min, we obtain fluorescence intensity measurements.

4.5. Determination of OTA in Practical Samples

In order to explore the feasibility of this method in real samples, red wine was used to test the feasibility. This was completed in order to reduce the influence of the color and residue of red wine on the experimental results. Red wine samples were filtrated first to remove the wine sediment and then diluted 20-fold for the subsequent analysis of OTA. Three different concentrations of OTA (1.2 ng/mL, 12 ng/mL, and 40 ng/mL) were spiked into the red wine samples to obtain standard samples. The subsequent manipulation was conducted according to the reported strategy.
  35 in total

1.  Evaluation of methods used to determine ochratoxin A in coffee beans.

Authors:  N E Ahmed; M M Farag; K M Soliman; A K M Abdel-Samed; Kh M Naguib
Journal:  J Agric Food Chem       Date:  2007-10-18       Impact factor: 5.279

2.  Label-free monitoring of DNA polymerase activity based on a thrombin-binding aptamer G-quadruplex.

Authors:  Jing Wang; Haisheng Liu; Changbei Ma; Jun Wang; Linxiu Zhong; Kefeng Wu
Journal:  Mol Cell Probes       Date:  2016-10-19       Impact factor: 2.365

Review 3.  Toxicity, metabolism, and impact of mycotoxins on humans and animals.

Authors:  H S Hussein; J M Brasel
Journal:  Toxicology       Date:  2001-10-15       Impact factor: 4.221

4.  Sensitive quantitation of Ochratoxin A in cocoa beans using differential pulse voltammetry based aptasensor.

Authors:  Rupesh K Mishra; Akhtar Hayat; Gaëlle Catanante; Georges Istamboulie; Jean-Louis Marty
Journal:  Food Chem       Date:  2015-07-21       Impact factor: 7.514

5.  Selection and characterization of a novel DNA aptamer for label-free fluorescence biosensing of ochratoxin A.

Authors:  Maureen McKeague; Ranganathan Velu; Kayla Hill; Viola Bardóczy; Tamás Mészáros; Maria C DeRosa
Journal:  Toxins (Basel)       Date:  2014-08-15       Impact factor: 4.546

6.  Highly Sensitive Colorimetric Detection of Ochratoxin A by a Label-Free Aptamer and Gold Nanoparticles.

Authors:  Yunxia Luan; Jiayi Chen; Cheng Li; Gang Xie; Hailong Fu; Zhihong Ma; Anxiang Lu
Journal:  Toxins (Basel)       Date:  2015-12-10       Impact factor: 4.546

7.  Silver Nanoparticle-Based Fluorescence-Quenching Lateral Flow Immunoassay for Sensitive Detection of Ochratoxin A in Grape Juice and Wine.

Authors:  Hu Jiang; Xiangmin Li; Ying Xiong; Ke Pei; Lijuan Nie; Yonghua Xiong
Journal:  Toxins (Basel)       Date:  2017-02-28       Impact factor: 4.546

8.  Construction of a Bivalent Thrombin Binding Aptamer and Its Antidote with Improved Properties.

Authors:  Quintin W Hughes; Bao T Le; Grace Gilmore; Ross I Baker; Rakesh N Veedu
Journal:  Molecules       Date:  2017-10-19       Impact factor: 4.411

9.  Development of a sphingosylphosphorylcholine detection system using RNA aptamers.

Authors:  Katsunori Horii; Kazuya Omi; Yoshihito Yoshida; Yuka Imai; Nobuya Sakai; Asako Oka; Hiromi Masuda; Makio Furuichi; Tetsuji Tanimoto; Iwao Waga
Journal:  Molecules       Date:  2010-08-20       Impact factor: 4.411

10.  A comparative identification of ochratoxin A in longan fruit pulp by high performance liquid chromatography-fluorescence detection and electron spray ionization-mass spectrometry.

Authors:  Jing Li; Haihui Xie; Bao Yang; Xinhong Dong; Linyan Feng; Feng Chen; Yueming Jiang
Journal:  Molecules       Date:  2010-01-29       Impact factor: 4.411

View more
  6 in total

Review 1.  Graphene/aptamer probes for small molecule detection: from in vitro test to in situ imaging.

Authors:  Yi Dong; Ting Zhang; Xiaoya Lin; Jiangtao Feng; Fang Luo; Hong Gao; Yangping Wu; Ruijie Deng; Qiang He
Journal:  Mikrochim Acta       Date:  2020-02-19       Impact factor: 5.833

2.  A Label-Free Fluorescent Assay for the Rapid and Sensitive Detection of Adenosine Deaminase Activity and Inhibition.

Authors:  Xinxing Tang; Kefeng Wu; Han Zhao; Mingjian Chen; Changbei Ma
Journal:  Sensors (Basel)       Date:  2018-07-27       Impact factor: 3.576

3.  Aptamer-Based Fluorometric Ochratoxin A Assay Based on Photoinduced Electron Transfer.

Authors:  Han Zhao; Xinying Xiang; Mingjian Chen; Changbei Ma
Journal:  Toxins (Basel)       Date:  2019-01-24       Impact factor: 4.546

4.  Label-Free Fluorescent Aptasensor for Ochratoxin-A Detection Based on CdTe Quantum Dots and (N-Methyl-4-pyridyl) Porphyrin.

Authors:  Li Liu; Zafar Iqbal Tanveer; Keqiu Jiang; Qingwen Huang; Jinghui Zhang; Yongjiang Wu; Zheng Han
Journal:  Toxins (Basel)       Date:  2019-07-28       Impact factor: 4.546

Review 5.  Marine Toxins Detection by Biosensors Based on Aptamers.

Authors:  Wei Ye; Taomei Liu; Weimin Zhang; Muzi Zhu; Zhaoming Liu; Yali Kong; Shan Liu
Journal:  Toxins (Basel)       Date:  2019-12-18       Impact factor: 4.546

6.  Amplified Fluorescent Aptasensor for Ochratoxin A Assay Based on Graphene Oxide and RecJf Exonuclease.

Authors:  Han Zhao; Dehui Xiong; Ying Yan; Changbei Ma
Journal:  Toxins (Basel)       Date:  2020-10-23       Impact factor: 4.546

  6 in total