Literature DB >> 29750926

Comparative safety and efficacy of a dedicated postpartum IUD inserter versus forceps for immediate postpartum IUD insertion: a randomized trial.

Paul D Blumenthal1, Klaira Lerma2, Renita Bhamrah3, Sharad Singh3.   

Abstract

OBJECTIVE: To compare postpartum intrauterine device (PPIUD) insertion using a newly developed dedicated PPIUD inserter (inserter) to insertion with modified Kelly placental forceps (forceps). STUDY
DESIGN: We randomized 500 women at five Indian academic centers to PPIUD insertion of a Copper T380A with either the inserter or forceps. The primary outcomes were fundal placement (assessed by postinsertion ultrasound), ease of insertion on a 5-point Likert scale and safety (infection/perforation). Secondary outcomes included IUD status at 6-8 weeks postpartum, assessed by string check, ultrasound or x-ray.
RESULTS: Between September 2015 and July 2016, 241 women in the inserter group and 239 women in the forceps group completed the study, with 20 women excluded due to consent withdrawal (n=4), lost to follow-up (n=10) and protocol deviation (n=6). Median distance from the fundus was similar (p=.36): 5.2 mm (0-130) and 5.8 mm (0-120) in the inserter and forceps groups, respectively. Most providers reported insertion to be easy or very easy with inserter (n=195, 81%) and forceps (n=206, 86%; p=.51). There were no perforations or insertion-related infections. Complete expulsion occurred in 19 (7.9%) in the inserter and 13 (5.4%) forceps groups (p=.28). The inserter group had more partial expulsions (n=26, 10.8% versus n=12, 5.0%,) and self-removals (n=4, 1.7% versus n=0); however, most retained their IUD [174 (72.2%) and 200 (83.7%), respectively] (p=.01). Strings were not visible at follow-up in 23 (13.1%) participants in the inserter group and 45 (22.4%) in the forceps group (p=.04).
CONCLUSIONS: High fundal placement was similar between groups, with strings subsequently seen more frequently in the inserter group. The inserter's increased partial expulsions and self-removals are likely associated with the longer string. IMPLICATIONS: The easily performed technique of Cu-T380A PPIUD insertion with the inserter may make immediate PPIUD insertions more convenient for patients and providers. The technique, involving less IUD manipulation and reduced dependence on extra instruments, could combine to make PPIUD a more popular option. Since this study has a short follow-up period, further study is needed to better understand comparative outcomes with longer follow-up. Additional research on string management for IUDs inserted with the inserter could help explain the increased number of partial expulsions.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  IUD; LARC; PPIUD; Postpartum contraception

Mesh:

Year:  2018        PMID: 29750926     DOI: 10.1016/j.contraception.2018.04.019

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  6 in total

1.  Deep Learning Algorithm-Based Ultrasound Image Information in Diagnosis and Treatment of Pernicious Placenta Previa.

Authors:  Xiao Yang; Zheng Chen; Xiaozhou Jia
Journal:  Comput Math Methods Med       Date:  2022-06-06       Impact factor: 2.809

2.  Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.

Authors:  Sarah H Averbach; Yokabed Ermias; Gary Jeng; Kathryn M Curtis; Maura K Whiteman; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Naomi K Tepper; Tara C Jatlaoui
Journal:  Am J Obstet Gynecol       Date:  2020-03-03       Impact factor: 8.661

3.  Helping Postpartum Women in Mali Achieve Their Fertility Intentions: Perspectives From Introduction of the Dedicated Postpartum IUD Inserter.

Authors:  Eva Burke; Marie Léa Dakouo; Laura Glish; Pierre Moon; Paul D Blumenthal
Journal:  Glob Health Sci Pract       Date:  2018-10-04

4.  Planning for work: Exploring the relationship between contraceptive use and women's sector-specific employment in India.

Authors:  Lotus McDougal; Abhishek Singh; Kaushalendra Kumar; Nabamallika Dehingia; Aluisio J D Barros; Fernanda Ewerling; Yamini Atmavilas; Anita Raj
Journal:  PLoS One       Date:  2021-03-11       Impact factor: 3.240

5.  Provision of immediate postpartum intrauterine contraception after vaginal birth within a public maternity setting: Health services research evaluation.

Authors:  Michelle Cooper; Kevin McGeechan; Anna Glasier; Shiona Coutts; Frances McGuire; Jeni Harden; Nicola Boydell; Sharon T Cameron
Journal:  Acta Obstet Gynecol Scand       Date:  2019-12-29       Impact factor: 3.636

6.  Exploring reasons for discontinuing use of immediate post-partum intrauterine device in Nepal: a qualitative study.

Authors:  Mahesh C Puri; Saugat Joshi; Aayush Khadka; Erin Pearson; Yasaswi Dhungel; Iqbal H Shah
Journal:  Reprod Health       Date:  2020-03-18       Impact factor: 3.223

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.