Literature DB >> 29734520

Routine measurements of factor VIII activity and inhibitor titer in the presence of emicizumab utilizing anti-idiotype monoclonal antibodies.

K Nogami1, T Soeda2, T Matsumoto1,3, Y Kawabe2, T Kitazawa2, M Shima1,3.   

Abstract

Essentials Emicizumab (Emi) affects the APTT-based assays of factor (F)VIII activity and inhibitor titer. A mixture of two anti-Emi monoclonal antibodies (mAb) effectively neutralized the Emi activity. Anti-Emi mAbs completely eliminated the influence of Emi on FVIII activity and inhibitor titer. The inclusion of anti-Emi mAbs in routine FVIII assays would be useful for Emi-treated patients.
SUMMARY: Background Emicizumab is an anti-factor (F)IXa/X bispecific monoclonal antibody (mAb), mimicking the factor (F)VIIIa cofactor activity. Emicizumab does not require activation by thrombin and its shortening effect on the activated partial prothrombin time (APTT) is more pronounced than that of factor (F)VIII. APTT-based FVIII activity (FVIII:C) and FVIII inhibiter titer measurements are influenced by the presence of emicizumab. Aim To establish a reliable APTT-based assay to measure FVIII in the presence of emicizumab. Methods Plasmas from hemophilia A (HA) patients without or with inhibitors were studied using one-stage FVIII:C and Bethesda inhibitor assays. Two recombinant anti-idiotype mAbs to emicizumab (anti-emicizumab mAbs) were prepared, rcAQ8 to anti-FIXa-Fab and rcAJ540 to anti-FX-Fab. Results The combined anti-idiotype mAbs (2000 nm each) eliminated the effects of emicizumab on APTTs of HA plasmas without or with inhibitor by competitive inhibition of antibody binding to FIX(a)/FX(a). Measurements of FVIII coagulation activity in HA plasmas without inhibitor were overestimated in the presence of emicizumab (1 μm = ~150 μg mL-1 ) at all reference levels of FVIII. The addition of anti-emicizumab mAbs to the assay mixtures completely neutralized the emicizumab and facilitated accurate determination of FVIII:C. Anti-FVIII inhibitor titers were undetectable in the presence of emicizumab in HA plasmas with inhibitor or normal plasmas mixed with anti-FVIII neutralizing antibodies. These effects of emicizumab were completely counteracted by the addition of the anti-idiotype mAbs, allowing accurate assessment of inhibitor titers. Conclusion The in vitro inclusion of anti-emicizumab mAbs in the standard one-stage coagulation assays prevented interference by emicizumab and enabled accurate measurements of FVIII:C and inhibitor titers.
© 2018 International Society on Thrombosis and Haemostasis.

Entities:  

Keywords:  anti-idiotypic antibody; blood coagulation factor inhibitor; emicizumab; factor VIII; hemophilia A

Mesh:

Substances:

Year:  2018        PMID: 29734520     DOI: 10.1111/jth.14135

Source DB:  PubMed          Journal:  J Thromb Haemost        ISSN: 1538-7836            Impact factor:   5.824


  20 in total

Review 1.  Position paper on laboratory testing for patients with haemophilia. A consensus document from SISET, AICE, SIBioC and SIPMeL.

Authors:  Armando Tripodi; Rita C Santoro; Sophie Testa; Angelo C Molinari; Sergio Bernardini; Maria Golato; Giuseppe Lippi; Walter Ageno; Elena Santagostino
Journal:  Blood Transfus       Date:  2019-02-04       Impact factor: 3.443

Review 2.  A Molecular Revolution in the Treatment of Hemophilia.

Authors:  John S S Butterfield; Kerry M Hege; Roland W Herzog; Radoslaw Kaczmarek
Journal:  Mol Ther       Date:  2019-11-13       Impact factor: 11.454

3.  Global coagulation function assessed by rotational thromboelastometry predicts coagulation-steady state in individual hemophilia A patients receiving emicizumab prophylaxis.

Authors:  Koji Yada; Keiji Nogami; Kenichi Ogiwara; Yasuaki Shida; Shoko Furukawa; Hiroaki Yaoi; Masahiro Takeyama; Ryu Kasai; Midori Shima
Journal:  Int J Hematol       Date:  2019-06-28       Impact factor: 2.490

4.  Emicizumab for the treatment of haemophilia A: a narrative review.

Authors:  Massimo Franchini; Giuseppe Marano; Ilaria Pati; Fabio Candura; Samantha Profili; Eva Veropalumbo; Francesca Masiello; Liviana Catalano; Vanessa Piccinini; Stefania Vaglio; Simonetta Pupella; Giancarlo M Liumbruno
Journal:  Blood Transfus       Date:  2019-05       Impact factor: 3.443

5.  Detailed analysis of anti-emicizumab antibody decreasing drug efficacy, using plasma samples from a patient with hemophilia A.

Authors:  Makoto Kaneda; Ryohei Kawasaki; Naoki Matsumoto; Hiroto Abe; Yoshihito Tashiro; Yuta Inokuchi; Hideyuki Yasuno; Mariko Sasaki-Noguchi; Tetsuhiro Soeda; Yasushi Yoshimura; Toshiaki Oka
Journal:  J Thromb Haemost       Date:  2021-09-28       Impact factor: 16.036

Review 6.  Emicizumab, a humanized bispecific antibody to coagulation factors IXa and X with a factor VIIIa-cofactor activity.

Authors:  Takehisa Kitazawa; Midori Shima
Journal:  Int J Hematol       Date:  2018-10-22       Impact factor: 2.490

Review 7.  Emicizumab: A Review in Haemophilia A.

Authors:  Hannah A Blair
Journal:  Drugs       Date:  2019-10       Impact factor: 9.546

Review 8.  Laboratory monitoring of hemophilia A treatments: new challenges.

Authors:  Peter J Lenting
Journal:  Blood Adv       Date:  2020-05-12

9.  Change of Amino Acid Residues in Idiotypic Nanobodies Enhanced the Sensitivity of Competitive Enzyme Immunoassay for Mycotoxin Ochratoxin A in Cereals.

Authors:  Caixia Zhang; Weiqi Zhang; Xiaoqian Tang; Qi Zhang; Wen Zhang; Peiwu Li
Journal:  Toxins (Basel)       Date:  2020-04-23       Impact factor: 4.546

Review 10.  Bispecific Antibodies and Advances in Non-Gene Therapy Options in Hemophilia.

Authors:  Midori Shima
Journal:  Res Pract Thromb Haemost       Date:  2020-04-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.