Literature DB >> 29733276

High-Frame-Rate Speckle-Tracking Echocardiography.

Philippe Joos, Jonathan Poree, Herve Liebgott, Didier Vray, Mathilde Baudet, Julia Faurie, Francois Tournoux, Guy Cloutier, Barbara Nicolas, Damien Garcia, Mathilde Baudet, Francois Tournoux, Philippe Joos, Jonathan Poree, Guy Cloutier, Herve Liebgott, Julia Faurie, Didier Vray, Barbara Nicolas, Damien Garcia.   

Abstract

Conventional echocardiography is the leading modality for noninvasive cardiac imaging. It has been recently illustrated that high-frame-rate echocardiography using diverging waves could improve cardiac assessment. The spatial resolution and contrast associated with this method are commonly improved by coherent compounding of steered beams. However, owing to fast tissue velocities in the myocardium, the summation process of successive diverging waves can lead to destructive interferences if motion compensation (MoCo) is not considered. Coherent compounding methods based on MoCo have demonstrated their potential to provide high-contrast B-mode cardiac images. Ultrafast speckle-tracking echocardiography (STE) based on common speckle-tracking algorithms could substantially benefit from this original approach. In this paper, we applied STE on high-frame-rate B-mode images obtained with a specific MoCo technique to quantify the 2-D motion and tissue velocities of the left ventricle. The method was first validated in vitro and then evaluated in vivo in the four-chamber view of 10 volunteers. High-contrast high-resolution B-mode images were constructed at 500 frames/s. The sequences were generated with a Verasonics scanner and a 2.5-MHz phased array. The 2-D motion was estimated with standard cross correlation combined with three different subpixel adjustment techniques. The estimated in vitro velocity vectors derived from STE were consistent with the expected values, with normalized errors ranging from 4% to 12% in the radial direction and from 10% to 20% in the cross-range direction. Global longitudinal strain of the left ventricle was also obtained from STE in 10 subjects and compared to the results provided by a clinical scanner: group means were not statistically different ( value = 0.33). The in vitro and in vivo results showed that MoCo enables preservation of the myocardial speckles and in turn allows high-frame-rate STE.

Entities:  

Mesh:

Year:  2018        PMID: 29733276     DOI: 10.1109/TUFFC.2018.2809553

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

Review 1.  Emerging clinical applications of strain imaging and three-dimensional echocardiography for the assessment of ventricular function in adult congenital heart disease.

Authors:  Michael Huntgeburth; Ingo Germund; Lianne M Geerdink; Narayanswami Sreeram; Floris E A Udink Ten Cate
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

2.  Block Matching Pyramid Algorithm-Based Analysis on Efficacy of Shexiang Baoxin Pills Guided by Echocardiogram (ECG) on Patients with Angina Pectoris in Coronary Heart Disease.

Authors:  Junqing Gao; Xu Wang; Lingyan Li; Hong Zhang; Ruiqing He; Bingyu Han; Zongjun Li
Journal:  J Healthc Eng       Date:  2021-08-06       Impact factor: 2.682

3.  Ultrafast Ultrasound Imaging for Super-Resolution Preclinical Cardiac PET.

Authors:  Mailyn Perez-Liva; Thulaciga Yoganathan; Joaquin L Herraiz; Jonathan Porée; Mickael Tanter; Daniel Balvay; Thomas Viel; Anikitos Garofalakis; Jean Provost; Bertrand Tavitian
Journal:  Mol Imaging Biol       Date:  2020-06-29       Impact factor: 3.488

4.  An optimisation-based iterative approach for speckle tracking echocardiography.

Authors:  Neda Azarmehr; Xujiong Ye; Joseph D Howes; Benjamin Docking; James P Howard; Darrel P Francis; Massoud Zolgharni
Journal:  Med Biol Eng Comput       Date:  2020-04-07       Impact factor: 2.602

5.  Assessment of left atrial function in feline hypertrophic cardiomyopathy by using two- dimensional speckle tracking echocardiography.

Authors:  Arisara Kiatsilapanan; Sirilak Disatian Surachetpong
Journal:  BMC Vet Res       Date:  2020-09-18       Impact factor: 2.741

6.  Speckle-Tracking Echocardiography with Novel Imaging Technique of Higher Frame Rate.

Authors:  Kana Fujikura; Mohammed Makkiya; Muhammad Farooq; Yun Xing; Wayne Humphrey; Mohammad Hashim Mustehsan; Mario J Garcia; Cynthia C Taub
Journal:  J Clin Med       Date:  2021-05-13       Impact factor: 4.241

7.  Software for Post-Processing Analysis of Strain Curves: The D-Station.

Authors:  Rafael Duarte de Sousa; Carlos Danilo Miranda Regis; Ittalo Dos Santos Silva; Paulo Szewierenko; Renato de Aguiar Hortegal; Henry Abensur
Journal:  Arq Bras Cardiol       Date:  2020 May-Jun       Impact factor: 2.000

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.