Joanna Dolar-Szczasny1, Anna Święch-Zubilewicz1, Jerzy Mackiewicz1.
Abstract
PURPOSE: To investigate retinal sensitivity characteristics associated with morphologic changes in the eyes exhibiting chronic central serous chorioretinopathy (CSC), using macular integrity assessment (MAIA) microperimetry.Entities:
Year: 2018 PMID: 29725542 PMCID: PMC5872652 DOI: 10.1155/2018/9479848
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Figure 1Optical coherence tomography of the macular region with subretinal fluid.
Figure 2Fluorescein angiography of the eye with central serous chorioretinopathy.
Figure 3Microperimetry examination of the eye with central serous chorioretinopathy performed with the macular integrity assessment instrument.
Clinical characteristics of patients with chronic central serous chorioretinopathy.
| Patient number | Age (years) | Visual acuity (logMAR) | Macular integrity | Average threshold (dB) | Microperimetry fixation stability P1 (%) | Microperimetry fixation stability P2 (%) |
|---|---|---|---|---|---|---|
| 2 | 40 | 0.18 | 48.5 | 27.3 | 100 | 100 |
| 3 | 35 | 0.0 | 13.7 | 29.0 | 94 | 99 |
| 4 | 43 | 0.1 | 53.4 | 27.7 | 72 | 90 |
| 5 | 36 | 0.2 | 93.6 | 25.5 | 100 | 100 |
| 6 | 43 | 0.7 | 52.6 | 12.1 | 76 | 95 |
| 7 | 47 | 0.1 | 35.0 | 28.6 | 99 | 100 |
| 8 | 40 | 0.18 | 92.0 | 26.1 | 100 | 100 |
| 9 | 35 | 0.18 | 7.6 | 29.4 | 82 | 97 |
| 10 | 48 | 0.3 | 58.4 | 22.5 | 100 | 100 |
| 11 | 36 | 0.2 | 41.6 | 28.1 | 94 | 100 |
| 12 | 41 | 0.5 | 65.6 | 13.7 | 90 | 95 |
| 13 | 42 | 0.3 | 81.4 | 16.5 | 56 | 88 |
| 14 | 45 | 0.2 | 56.4 | 27.3 | 99 | 100 |
| 15 | 51 | 0.2 | 26.9 | 27.5 | 100 | 100 |
Clinical characteristics of control subjects.
| Patient number | Age (years) | Visual acuity (logMAR) | Macular integrity | Average threshold (dB) | Microperimetry fixation stability P1 (%) | Microperimetry fixation stability P2 (%) |
|---|---|---|---|---|---|---|
| 1 | 36 | 0.0 | 3.6 | 30.2 | 99 | 100 |
| 2 | 35 | 0.0 | 0.2 | 35.5 | 100 | 100 |
| 3 | 42 | 0.0 | 1.4 | 30.8 | 100 | 100 |
| 4 | 43 | 0.0 | 2.8 | 28.2 | 100 | 100 |
| 5 | 35 | 0.0 | 1.2 | 29.6 | 100 | 100 |
| 6 | 38 | 0.0 | 5.0 | 32.7 | 100 | 100 |
| 7 | 24 | 0.0 | 3.8 | 31.8 | 98 | 100 |
| 8 | 41 | 0.0 | 4.2 | 27.8 | 100 | 100 |
| 9 | 43 | 0.0 | 2.4 | 33.8 | 97 | 100 |
| 10 | 47 | 0.1 | 1.2 | 29.6 | 100 | 100 |
| 11 | 40 | 0.0 | 5.6 | 34.2 | 95 | 100 |
| 12 | 39 | 0.0 | 2.2 | 35.2 | 100 | 100 |
| 13 | 37 | 0.0 | 1.8 | 32.8 | 100 | 100 |
| 14 | 46 | 0.1 | 0.4 | 31.6 | 100 | 100 |
| 15 | 42 | 0.0 | 3.4 | 26.8 | 100 | 100 |
Mean visual acuity, macular integrity index, average threshold, and fixation stability in eyes with chronic central serous chorioretinopathy and control eyes.
| Control eyes (mean ± SD) | Eyes with chronic CSC (mean ± SD) | Statistic ( |
| |
|---|---|---|---|---|
| Visual acuity (logMAR) | 0.0 ± 0.0 | 0.2 ± 0.2 | 0.00 |
|
| Macular integrity | 2.6 ± 1.6 | 49.0 ± 27.6 | 0.00 |
|
| Average threshold (dB) | 31.4 ± 2.7 | 24.7 ± 5.8 | 0.01 |
|
| Fixation stability P1 (%) | 99.3 ± 1.5 | 90.1 ± 13.7 | 0.01 |
|
| Fixation stability P2 (%) | 100.0 ± 0.0 | 97.4 ± 4.0 | 0.02 |
|