Application of contrast-enhanced ultrasound in the diagnosis of small breast lesions.

Yan-Ran Du1, Yang Wu1, Man Chen2, Xin-Gang Gu1.   

Abstract

BACKGROUND: Breast cancer is the most common cancer in women worldwide. The purpose of the study was to observe the features of contrast-enhanced ultrasound (CEUS) and the combination with Breast Imaging-Reporting and Data System (BI-RADS) of conventional ultrasound for assessing small breast lesions.
OBJECTIVES: The study was to explore the small breast lesions' features of contrast-enhanced ultrasound (CEUS) and the combination with Breast Imaging-Reporting and Data System (BI-RADS) of conventional ultrasound, in order to improve the diagnostic accuracy of early breast cancer.
METHODS: 105 lesions were subject to conventional US (ultrasound) and CEUS before operations or biopsies. Among 105 breast lesions, six patient diagnoses were established by thick core-needle biopsy, while the rest were all confirmed by surgery and pathology.
RESULTS: Significant differences were found between benign and malignant lesions in qualitative and quantitative indexes (peak) of CEUS (P < 0.05). The qualitative features of malignant small breast lesions were as follows: (1) enhanced intensity within the lesion was not uniform (61/61,100%); (2) the speed of wash-in was earlier than the surrounding tissue (58/61, 95.1%); (3) lesion interior and the surrounding tissues had contrast vessel performance (61/61,100%). Peak of malignant lesions (35.77±11.45) was higher than that of benign lesions (31.96±10.76) (P < 0.05). The diagnostic performance of BI-RADS-US plus qualitative indexes (method one) in terms of area under receiver operating characteristic curve (AUROC) were the highest (i.e., AUROC = 0.817), in comparison with other combined diagnostic methods. The associated sensitivity, specificity and accuracy were 78.69%, 84.09% and 80.95%, respectively. With method one, however, was similar with US-BI-RADS in specificity, 11 malignant breast lesions were regarded as a higher classification of BI-RADS and classified into malignant group, which were identified as benign on US-BI-RADS originally.
CONCLUSIONS: CEUS was useful to differentiate benign from malignant small breast lesions, and the combination of CEUS and BI-RADS-US can improve the early diagnosis of breast cancers.

Entities:  

Keywords:  Small breast lesions; breast imaging-reporting and data system; contrast-enhanced ultrasound; peak intensity

Mesh:

Substances:

Year:  2018        PMID: 29710688     DOI: 10.3233/CH-170368

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  7 in total

1.  Ultrasound high-definition microvasculature imaging with novel quantitative biomarkers improves breast cancer detection accuracy.

Authors:  Redouane Ternifi; Yinong Wang; Juanjuan Gu; Eric C Polley; Jodi M Carter; Sandhya Pruthi; Judy C Boughey; Robert T Fazzio; Mostafa Fatemi; Azra Alizad
Journal:  Eur Radiol       Date:  2022-04-29       Impact factor: 7.034

Review 2.  Contrast-enhanced ultrasound perfusion imaging of organs.

Authors:  Ernst-Michael Jung; Marc-André Weber; Isabel Wiesinger
Journal:  Radiologe       Date:  2021-08-10       Impact factor: 0.635

3.  Can acoustic structural quantification be used to characterize the ultrasound echotexture of the peripheral zone of breast lesions?

Authors:  Annika Bach; Clarissa Hameister; Torsten Slowinski; Ernst Michael Jung; Anke Thomas; Thomas Fischer
Journal:  Clin Hemorheol Microcirc       Date:  2019       Impact factor: 2.375

Review 4.  Contrast-Enhanced Ultrasonography in the Diagnosis and Treatment Modulation of Breast Cancer.

Authors:  Ioana Boca Bene; Sorin M Dudea; Anca I Ciurea
Journal:  J Pers Med       Date:  2021-01-30

5.  Quantification and Classification of Contrast Enhanced Ultrasound Breast Cancer Data: A Preliminary Study.

Authors:  Georgios S Ioannidis; Michalis Goumenakis; Ioannis Stefanis; Apostolos Karantanas; Kostas Marias
Journal:  Diagnostics (Basel)       Date:  2022-02-06

6.  Comparison of Linear and Convex-Array Transducers in Assessing the Enhancement Characteristics of Suspicious Breast Lesions at Contrast-Enhanced Ultrasound (CEUS).

Authors:  Ioana Boca Bene; Anca Ileana Ciurea; Cristiana Augusta Ciortea; Ștefan Cristian Vesa; Sorin Marian Dudea
Journal:  Diagnostics (Basel)       Date:  2022-03-24

7.  Diagnostic Significance of 3D Automated Breast Volume Scanner in a Combination with Contrast-Enhanced Ultrasound for Breast Cancer.

Authors:  Quan Yuan; Canxu Song; Yan Tian; Nan Chen; Xing He; Ying Wang; Pihua Han
Journal:  Biomed Res Int       Date:  2022-08-03       Impact factor: 3.246

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.