Literature DB >> 29706403

Facile preparation of an alternating copolymer-based high molecular shape-selective organic phase for reversed-phase liquid chromatography.

Abul K Mallik1, Hiroki Noguchi2, Mohammed Mizanur Rahman3, Makoto Takafuji4, Hirotaka Ihara5.   

Abstract

The synthesis of a new alternating copolymer-grafted silica phase is described for the separation of shape-constrained isomers of polycyclic aromatic hydrocarbons (PAHs) and tocopherols in reversed-phase high-performance liquid chromatography (RP-HPLC). Telomerization of the monomers (octadecyl acrylate and N-methylmaleimide) was carried out with a silane coupling agent; 3-mercaptopropyltrimethoxysilane (MPS), and the telomer (T) was grafted onto porous silica surface to prepare the alternating copolymer-grafted silica phase (Sil-alt-T). The new hybrid material was characterized by elemental analyses, diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy, and solid-state 13C and 29Si cross-polarization magic-angle spinning (CP/MAS) NMR spectroscopy. The results of 13C CP/MAS NMR demonstrated that the alkyl chains of the grafted polymers in Sil-alt-T remained disordered, amorphous, and mobile represented by gauche conformational form. Separation abilities and molecular-shape selectivities of the prepared organic phase were evaluated by the separation of PAHs isomers and Standard Reference Material 869b, Column Selectivity Test Mixture for Liquid Chromatography, respectively and compared with commercially available octadecylsilylated silica (ODS) and C30 columns as well as previously reported alternating copolymer-based column. The effectiveness of this phase is also demonstrated by the separation of tocopherol isomers. Oriented functional groups along the polymer main chains and cavity formations are investigated to be the driving force for better separation with multiple-interactions with the solutes. One of the advantages of the Sil-alt-T phase to that of the previously reported phase is the synthesis of the telomer first and then immobilized onto silica surface. In this case, the telomer was characterized easily with simple spectroscopic techniques and the molecular mass and polydispersity index of the telomer were determined by size exclusion chromatography (SEC) before grafting onto silica surface. Moreover, both of the monomers were commercially available. Therefore, the technique of preparation was very facile and better separation was achieved with the Sil-alt-T phase compared to the ODS, C30 and other previously reported alternating copolymer-based columns.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Alternating copolymer; Liquid chromatography; Polycyclic aromatic hydrocarbons; Shape selectivity; Telomer; Tocopherols

Mesh:

Substances:

Year:  2018        PMID: 29706403     DOI: 10.1016/j.chroma.2018.04.047

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

Review 1.  Recent Developments of Liquid Chromatography Stationary Phases for Compound Separation: From Proteins to Small Organic Compounds.

Authors:  Handajaya Rusli; Rindia M Putri; Anita Alni
Journal:  Molecules       Date:  2022-01-28       Impact factor: 4.411

2.  [Novel submicron nonporous silica material modification with high carbon content and its application in reversed-phase pressurized capillary electrochromatography].

Authors:  Zihang Xia; Cheddah Soumia; Weiwei Wang; Yan Wang; Chao Yan
Journal:  Se Pu       Date:  2022-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.