Literature DB >> 29704799

Simultaneous determination of cyclosporine and tacrolimus in human whole blood by ultra-high performance liquid chromatography tandem mass spectrometry and comparison with a chemiluminescence microparticle immunoassay.

Shenghui Mei1, Jiaqing Wang2, Di Chen3, Leting Zhu2, Ming Zhao3, Xiaoxin Tian3, Xin Hu4, Zhigang Zhao5.   

Abstract

Overestimation of immunoassays for cyclosporine (CsA) and tacrolimus (TAC) analysis in human whole blood is a problem. The liquid chromatography tandem mass spectrometry is recommended as a golden method for CsA and TAC analysis. The aim of the study is to develop and validate an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of CsA and TAC in human whole blood and evaluate its agreement with a chemiluminescence microparticle immunoassay (CMIA). The UHPLC-MS/MS method for simultaneous determination of CsA and TAC in human whole blood was developed and validated according to the guidelines. A total of 177 CsA and 220 TAC samples were determined by UHPLC-MS/MS and CMIA, and the agreement of the two methods was evaluated by Bland-Altman plot. The calibration range of UHPLC-MS/MS method was 5 to 2000 ng/mL for CsA and 0.2 to 80 ng/mL for TAC. The inaccuracy and imprecision were -13.33% to 11.80% and <11.74% for CsA and -8.94% to 6.53% and <10.84% for TAC, respectively. Evaluated by Bland-Altman plot, the mean overestimation of CMIA compared to UHPLC-MS/MS was 53.7% for CsA and 48.1% for TAC.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chemiluminescence microparticle immunoassay; Cyclosporine; Immunosuppressive drug monitoring; Method comparison; Tacrolimus; UHPLC-MS/MS

Mesh:

Substances:

Year:  2018        PMID: 29704799     DOI: 10.1016/j.jchromb.2018.04.028

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Simultaneous Determination of Six Immunosuppressants in Human Whole Blood by HPLC-MS/MS Using a Modified QuEChERS Method.

Authors:  Min Zheng; Jianshi Song; Hua Xue; Hui Li; Kaoqi Lian
Journal:  Molecules       Date:  2022-06-25       Impact factor: 4.927

2.  Validation of a novel UPLC-HRMS method for human whole-blood cyclosporine and comparison with a CMIA immunoassay.

Authors:  Xiaoxue Wang; Wei Qin; Wenqian Chen; Huifang Liu; Dan Zhang; Xianglin Zhang; Pengmei Li
Journal:  Exp Ther Med       Date:  2021-01-07       Impact factor: 2.447

3.  A modified LC-MS/MS method for the detection of whole blood tacrolimus and its clinical value in Chinese kidney transplant patients.

Authors:  Ke-Wei Yu; Bing-Ling Li; Ying-Shi Yuan; Jia-Min Liao; Wei-Kang Li; Heng Dong; Pei-Feng Ke; Xing Jin; Lu Chen; Jing-Jing Zhao; Heng Wang; Shun-Wang Cao; Wei-Ye Chen; Xian-Zhang Huang; Bei-Bei Zhao; Chun-Min Kang
Journal:  Heliyon       Date:  2022-08-13

4.  [Adsorption, separation, and purification of cyclosporine A using reversed-phase liquid chromatography].

Authors:  Zhidong Li; Qing Fu; Zhuoshun Dai; Yu Jin; Xinmiao Liang
Journal:  Se Pu       Date:  2022-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.