Literature DB >> 25944553

Risk Assessment of Tendon Attrition Following Treatment of Distal Radius Fractures With Volar Locking Plates Using Audible Crepitus and Placement of the Plate: A Prospective Clinical Cohort Study.

Hiroshi Yamazaki1, Shigeharu Uchiyama2, Masatoshi Komatsu3, Shun Hashimoto3, Hiroyuki Kato2.   

Abstract

PURPOSE: To identify risk factors for tendon attrition after volar locking plate fixation of distal radius fractures.
METHODS: We prospectively assessed attrition of the flexor pollicis longus tendon at volar plate removal in 127 hands in 126 patients. We also evaluated preoperative lateral wrist radiographs, sonographs, and crepitus with flexor pollicis longus tendon motion and compared the demographic and radiographic characteristics of patients with and without tendon attrition. Multivariate logistic regression analysis was employed to identify the factors independently associated with tendon attrition.
RESULTS: We found 12 cases of tendon attrition (10%) and 1 that presented with tendon rupture in our cohort. Crepitus was recognized in 14 patients (11%): 6 cases (50%) were among the 12 hands in 12 patients with tendon attrition whereas 8 (7%) were detected in the remaining 114 hands in 113 patients. Logistic regression examination revealed that audible crepitus and volar placement of the plate in lateral radiographs were independent predictors of tendon attrition.
CONCLUSIONS: Crepitus and volar placement of hardware in lateral radiographs were independent risk factors for flexor tendon attrition after volar plating for distal radius fracture. These results may facilitate surgical decisions regarding early plate removal to prevent possible tendon rupture. TYPE OF STUDY/LEVEL OF EVIDENCE: Diagnostic II.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Distal radius fracture; crepitus; flexor tendon rupture; tendon attrition; volar locking plate

Mesh:

Year:  2015        PMID: 25944553     DOI: 10.1016/j.jhsa.2015.03.023

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  5 in total

1.  Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius.

Authors:  Takuya Uemura; Tadashi Okano; Ema Onode; Takuya Yokoi; Kosuke Shintani; Mitsuhiro Okada; Hiroaki Nakamura
Journal:  J Med Ultrason (2001)       Date:  2018-04-27       Impact factor: 1.314

2.  Incidence of tendon rupture following volar plate fixation of distal radius fractures: A survey of 2787 cases.

Authors:  Kotaro Sato; Kenya Murakami; Yoshikuni Mimata; Minoru Doita
Journal:  J Orthop       Date:  2018-02-03

3.  Anatomical-positional relationship between the bone structure of the distal radius and flexor pollicis longus tendon using ultrasonography.

Authors:  Mayuko Kinoshita; Kiyohito Naito; Kenji Goto; Yoichi Sugiyama; Nana Nagura; Hiroyuki Obata; Yoshiyuki Iwase; Kazuo Kaneko
Journal:  Surg Radiol Anat       Date:  2019-03-16       Impact factor: 1.246

4.  Anterior interosseous nerve palsy mimicking rupture of the index flexor digitorum profundus after volar locking plate fixation of a distal radius fracture.

Authors:  Takaaki Shinohara; Sayako Takahashi; Hitoshi Hirata
Journal:  Nagoya J Med Sci       Date:  2017-08       Impact factor: 1.131

5.  Volar locking plates not touching the flexor pollicis longus tendon appear as prominences on radiographs: a cadaver study.

Authors:  Kotaro Sato; Yuki Kikuchi; Yoshikuni Mimata; Kenya Murakami; Gaku Takahashi; Minoru Doita
Journal:  J Orthop Traumatol       Date:  2019-08-20
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.