| Literature DB >> 29702617 |
Borja Ribed-Sánchez1,2, Cristina González-Gaya3, Sara Varea-Díaz4, Carlos Corbacho-Fabregat5, Jaime Pérez-Oteyza6, Cristóbal Belda-Iniesta7.
Abstract
BACKGROUND: Two million transfusions are performed in Spain every year. These come at a high economic price for the health system, increasing the morbidity and mortality rates. The way of obtaining the hemoglobin concentration value is via invasive and intermittent methods, the results of which take time to obtain. The drawbacks of this method mean that some transfusions are unnecessary. New continuous noninvasive hemoglobin measurement technology can save unnecessary transfusions.Entities:
Keywords: cost savings; hemoglobin; photoplethysmography; real-time monitoring; spectrophotometry; transfusions
Mesh:
Substances:
Year: 2018 PMID: 29702617 PMCID: PMC5981621 DOI: 10.3390/s18051367
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Absorption spectra of blood components [12].
p-Value analysis for age and prior hemoglobin (Hb) value between control and experimental groups.
| Group Features | Total Patients | Average Age (years) | Standard Deviation (years) | Prior Hb Value (g/dL) | Standard Deviation (g/dL) |
|---|---|---|---|---|---|
| Control group | 115 | 71.86 | 15.297 | 13.32 | 2.073 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Experimental group | 122 | 71.56 | 71.56 | 13.53 | 1.901 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0.88 | 0.4238 | ||||
Transfusion results.
| Group Features | Total Patients (No.) | Transfusions (No.) | Transfusions (%) | Units of Blood (No.) | Units per Patient (No.) |
|---|---|---|---|---|---|
| Control Group | 115 | 56 | 48.7 | 152 | 1.322 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Experimental Group | 122 | 55 | 45.1 | 141 | 1.156 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Hip surgery cases in Spain. 2015. Source: Spanish Ministry for Health. DRG: diagnosis-related group.
| DRG Code | DRG Description | Cases (No.) |
|---|---|---|
| 210 | Hip & femur procedures except major joint age >17 with complications | 13,278 |
| 211 | Hip & femur procedures except major joint age >17 without complications | 21,765 |
| 212 | Hip & femur procedures except major joint age 0–17 | 1608 |
| 230 | Local excision & removal of int fix devices of hip and femur | 3047 |
| 817 | Hip replacement or review due to complications | 4953 |
| 818 | Hip replacement except for complications | 36,678 |
| Total | 81,329 |
Estimated savings per patient (€) depending on units transfused (No.) and cost of purchasing the SpHb® sensor (€).
| Units Transfused per Patient (No.) | ||||||||
|---|---|---|---|---|---|---|---|---|
| 2.00 | 1.75 | 1.50 | 1.25 | 1.00 | 0.75 | 0.50 | ||
|
|
| 93.2 | 81.6 | 69.9 | 58.3 | 46.6 | 35.0 | 23.3 |
|
| 88.2 | 76.6 | 64.9 | 53.3 | 41.6 | 30.0 | 18.3 | |
|
| 83.2 | 71.6 | 59.9 | 48.3 | 36.6 | 25.0 | 13.3 | |
|
| 78.2 | 66.6 | 54.9 | 43.3 | 31.6 | 20.0 | 8.3 | |
|
| 73.2 | 61.6 | 49.9 | 38.3 | 26.6 | 15.0 | 3.3 | |
|
| 68.2 | 56.6 | 44.9 | 33.3 | 21.6 | 10.0 | −1.7 | |
|
| 63.2 | 51.6 | 39.9 | 28.3 | 16.6 | 5.0 | −6.7 | |
|
| 58.2 | 46.6 | 34.9 | 23.3 | 11.6 | 0.0 | −11.7 | |
|
| 53.2 | 41.6 | 29.9 | 18.3 | 6.6 | −5.0 | −16.7 | |
|
| 48.2 | 36.6 | 24.9 | 13.3 | 1.6 | −10.0 | −21.7 | |
|
| 43.2 | 31.6 | 19.9 | 8.3 | −3.4 | −15.0 | −26.7 | |
|
| 38.2 | 26.6 | 14.9 | 3.3 | −8.4 | −20.0 | −31.7 | |
|
| 33.2 | 21.6 | 9.9 | −1.7 | −13.4 | −25.0 | −36.7 | |
|
| 28.2 | 16.6 | 4.9 | −6.7 | −18.4 | −30.0 | −41.7 | |
Figure 2Cost-effectiveness matrix.