Literature DB >> 29700783

Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis.

Francesco Scardulla1, Valentina Agnese2, Giuseppe Romano2, Gabriele Di Gesaro2, Sergio Sciacca2, Diego Bellavia2, Francesco Clemenza2, Michele Pilato2, Salvatore Pasta3,4.   

Abstract

The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the RV free wall vs. patient-specific computational strain estimations, and by non-invasive lumped-based hemodynamic predictions vs. invasive right heart catheterization data. Correlation analysis revealed that lumped-derived RV cardiac output (R = 0.94) and RV stroke work index (R = 0.85) were in good agreement with catheterization data collected from 7 patients with CF-LVAD. Biventricular FE analysis showed abnormal motion of the interventricular septum towards the left ventricular free wall, suggesting impaired right heart mechanics. Good agreement between computationally predicted and echocardiographic measured longitudinal strains was found at basal (- 19.1 ± 3.0% for ECHO, and - 16.4 ± 3.2% for FEM), apical (- 20.0 ± 3.7% for ECHO, and - 17.4 ± 2.7% for FEM), and mid-level of the RV free wall (- 20.1 ± 5.9% for echo, and - 18.0 ± 5.4% for FEM). Simulation approach here presented could serve as a tool for less invasive and early diagnosis of the severity of RV failure in patients with LVAD, although future studies are needed to validate our findings against clinical outcomes.

Entities:  

Keywords:  Finite-element analysis; Left ventricular assist device; Lumped-parameter; Right ventricular failure; Speckle-tracking echocardiography

Mesh:

Year:  2018        PMID: 29700783     DOI: 10.1007/s13239-018-0358-x

Source DB:  PubMed          Journal:  Cardiovasc Eng Technol        ISSN: 1869-408X            Impact factor:   2.495


  4 in total

1.  Detailed structural assessment of healthy interventricular septum in the presence of remodeling infarct in the free wall - A finite element model.

Authors:  Fulufhelo Nemavhola
Journal:  Heliyon       Date:  2019-06-06

2.  On the Left Ventricular Remodeling of Patients with Stenotic Aortic Valve: A Statistical Shape Analysis.

Authors:  Salvatore Cutugno; Tommaso Ingrassia; Vincenzo Nigrelli; Salvatore Pasta
Journal:  Bioengineering (Basel)       Date:  2021-05-13

3.  Synergistic Model of Cardiac Function with a Heart Assist Device.

Authors:  Eun-Jin Kim; Massimo Capoccia
Journal:  Bioengineering (Basel)       Date:  2019-12-19

Review 4.  A Meta-Analysis on Prophylactic Donor Heart Tricuspid Annuloplasty in Orthotopic Heart Transplantation: High Hopes from a Small Intervention.

Authors:  Alberto Emanuel Bacusca; Andrei Tarus; Alexandru Burlacu; Mihail Enache; Grigore Tinica
Journal:  Healthcare (Basel)       Date:  2021-03-10
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.