Literature DB >> 29700595

Ultrasonographic reference values for the median nerve at the level of pronator teres muscle.

Arash Babaei-Ghazani1, Peyman Roomizadeh2, Esmaeil Nouri1, Golnaz Raeisi1, Naseh Yousefi1, Mahdieh Asilian-Mahabadi1, Mohammad Moeini3.   

Abstract

PURPOSE: The purpose of this study was to investigate the ultrasonographic reference values for diameters and cross-sectional area (CSA) of the median nerve between the two heads of the pronator teres muscle in healthy population as well as to correlate the findings with height, weight, sex and age.
METHODS: Fifty-five healthy Caucasian volunteers (110 median nerves) were included in this study. The reference range (mean ± 2 standard deviations; 2.5th-97.5th quintiles) and the upper limit of side-to-side difference of the median nerve between the two heads of the pronator teres muscle were investigated using high-frequency ultrasound. The effects of age, sex, height, handedness, and body mass index (BMI) were examined.
RESULTS: The mean age was 39.4 ± 10.6 years (range 18-75 years). The mean ± 2SD of the median CSA was 4.9-12.9 mm2. The upper limit of normal side-to-side difference was 3.0 mm2. The differences between genders and between the dominant and non-dominant hands were not significant. The mean antero-posterior and transverse diameters were 7.2 ± 1.5 and 10.7 ± 2.4 mm, respectively. Significant correlations were observed between the dominant-side CSA and BMI (r = 0.33; p = 0.01) and age (r = 0.31; p = 0.02). The correlation between the CSA and height (r = 0.19; p = 0.16) was not significant.
CONCLUSIONS: The measurements obtained in this study are of importance for examining median nerve entrapments in the forearm using high-frequency ultrasound. Age and BMI showed to be correlated with median nerve CSA; while gender and height were not.

Entities:  

Keywords:  Entrapment; Median nerve; Pronator teres; Reference values; Ultrasonography

Mesh:

Year:  2018        PMID: 29700595     DOI: 10.1007/s00276-018-2016-2

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  23 in total

1.  Reference values for ultrasonograpy of peripheral nerves.

Authors:  Mohammad Qrimli; Hamid Ebadi; Ari Breiner; Hafsah Siddiqui; Majed Alabdali; Alon Abraham; Leif E Lovblom; Bruce A Perkins; Vera Bril
Journal:  Muscle Nerve       Date:  2016-04       Impact factor: 3.217

2.  Comparison of sonography and electrodiagnostic testing in the diagnosis of carpal tunnel syndrome.

Authors:  Bong Cheol Kwon; Kwang-Ik Jung; Goo Hyun Baek
Journal:  J Hand Surg Am       Date:  2008-01       Impact factor: 2.230

Review 3.  Diagnostic accuracy of ultrasonography vs. electromyography in carpal tunnel syndrome: a systematic review of literature.

Authors:  Shawn C Roll; Jane Case-Smith; Kevin D Evans
Journal:  Ultrasound Med Biol       Date:  2011-08-06       Impact factor: 2.998

4.  Median nerve compression at the fibrous arch of the flexor digitorum superficialis: an anatomic study of the pronator syndrome.

Authors:  Bev Guo; Angela Wang
Journal:  Hand (N Y)       Date:  2014-12

5.  The effect of magnification on sonographically measured nerve cross-sectional area.

Authors:  Elena J Jelsing; James C Presley; Eugene Maida; Nicholas J Hangiandreou; Jay Smith
Journal:  Muscle Nerve       Date:  2014-11-19       Impact factor: 3.217

Review 6.  The role of ultrasound in the diagnosis and management of carpal tunnel syndrome: a new paradigm.

Authors:  Cara McDonagh; Michael Alexander; David Kane
Journal:  Rheumatology (Oxford)       Date:  2014-08-12       Impact factor: 7.580

7.  Ulnar Tunnel Syndrome, Radial Tunnel Syndrome, Anterior Interosseous Nerve Syndrome, and Pronator Syndrome.

Authors:  Adam B Strohl; David S Zelouf
Journal:  J Am Acad Orthop Surg       Date:  2017-01       Impact factor: 3.020

8.  Proximal median neuropathies: electromyographic and clinical correlation.

Authors:  P T Gross; H R Jones
Journal:  Muscle Nerve       Date:  1992-03       Impact factor: 3.217

9.  Ultrasonographic reference values for assessing normal radial nerve ultrasonography in the normal population.

Authors:  Jun Chen; Shan Wu; Jun Ren
Journal:  Neural Regen Res       Date:  2014-10-15       Impact factor: 5.135

10.  Relationship Between Electrodiagnosis and Various Ultrasonographic Findings for Diagnosis of Carpal Tunnel Syndrome.

Authors:  Kyoung Moo Lee; Hyo Jong Kim
Journal:  Ann Rehabil Med       Date:  2016-12-30
View more
  1 in total

1.  Cross-sectional area reference values for high-resolution ultrasonography of the upper extremity nerves in healthy Asian adults.

Authors:  Dae Woong Bae; Jae Young An
Journal:  Medicine (Baltimore)       Date:  2021-05-07       Impact factor: 1.889

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.