Literature DB >> 29697462

Ex-vivo machine perfusion for kidney preservation.

Matyas Hamar1, Markus Selzner.   

Abstract

PURPOSE OF REVIEW: Machine perfusion is a novel strategy to decrease preservation injury, improve graft assessment, and increase organ acceptance for transplantation. This review summarizes the current advances in ex-vivo machine-based kidney preservation technologies over the last year. RECENT
FINDINGS: Ex-vivo perfusion technologies, such as hypothermic and normothermic machine perfusion and controlled oxygenated rewarming, have gained high interest in the field of organ preservation. Keeping kidney grafts functionally and metabolically active during the preservation period offers a unique chance for viability assessment, reconditioning, and organ repair. Normothermic ex-vivo kidney perfusion has been recently translated into clinical practice. Preclinical results suggest that prolonged warm perfusion appears superior than a brief end-ischemic reconditioning in terms of renal function and injury. An established standardized protocol for continuous warm perfusion is still not available for human grafts.
SUMMARY: Ex-vivo machine perfusion represents a superior organ preservation method over static cold storage. There is still an urgent need for the optimization of the perfusion fluid and machine technology and to identify the optimal indication in kidney transplantation. Recent research is focusing on graft assessment and therapeutic strategies.

Entities:  

Mesh:

Year:  2018        PMID: 29697462     DOI: 10.1097/MOT.0000000000000524

Source DB:  PubMed          Journal:  Curr Opin Organ Transplant        ISSN: 1087-2418            Impact factor:   2.640


  10 in total

1.  Synthetic hemoglobin-based oxygen carriers are an acceptable alternative for packed red blood cells in normothermic kidney perfusion.

Authors:  Mohamed M Aburawi; Fermin M Fontan; Negin Karimian; Corey Eymard; Stephanie Cronin; Casie Pendexter; Sonal Nagpal; Peony Banik; Sinan Ozer; Paria Mahboub; Francis L Delmonico; Heidi Yeh; Korkut Uygun; James F Markmann
Journal:  Am J Transplant       Date:  2019-04-26       Impact factor: 8.086

2.  Ex-Vivo Normothermic Limb Perfusion With a Hemoglobin-Based Oxygen Carrier Perfusate.

Authors:  Sayf A Said; Carlos X Ordeñana; Majid Rezaei; Brian A Figueroa; Srinivasan Dasarathy; Henri Brunengraber; Antonio Rampazzo; Bahar Bassiri Gharb
Journal:  Mil Med       Date:  2020-01-07       Impact factor: 1.437

3.  Effects of Normothermic Machine Perfusion Conditions on Mesenchymal Stromal Cells.

Authors:  Jesus M Sierra Parraga; Kaithlyn Rozenberg; Marco Eijken; Henri G Leuvenink; James Hunter; Ana Merino; Cyril Moers; Bjarne K Møller; Rutger J Ploeg; Carla C Baan; Bente Jespersen; Martin J Hoogduijn
Journal:  Front Immunol       Date:  2019-04-10       Impact factor: 7.561

Review 4.  A Review of Current and Emerging Trends in Donor Graft-Quality Assessment Techniques.

Authors:  Natalia Warmuzińska; Kamil Łuczykowski; Barbara Bojko
Journal:  J Clin Med       Date:  2022-01-18       Impact factor: 4.241

5.  An enhanced level of VCAM in transplant preservation fluid is an independent predictor of early kidney allograft dysfunction.

Authors:  Michael Baboudjian; Bastien Gondran-Tellier; Romain Boissier; Patricia Ancel; Juline Marjollet; Luc Lyonnet; Pauline François; Florence Sabatier; Eric Lechevallier; Anne Dutour; Pascale Paul
Journal:  Front Immunol       Date:  2022-08-11       Impact factor: 8.786

6.  HBOC-301 in Porcine Kidney Normothermic Machine Perfusion and the Effect of Vitamin C on Methemoglobin Formation.

Authors:  Eileen Edgworth; Lisa Ernst; Zoltan Czigany; Turgay Saritas; Laura Sophie Zarnitz; Marc Wiartalla; Peter Boor; Eva Miriam Buhl; Rolf Rossaint; René H Tolba; Benedict Doorschodt; Gregor Fabry; Christian Bleilevens
Journal:  Antioxidants (Basel)       Date:  2022-07-06

7.  Protection of the transplant kidney during cold perfusion with doxycycline: proteomic analysis in a rat model.

Authors:  Michael A J Moser; Katherine Sawicka; Jolanta Sawicka; Aleksandra Franczak; Alejandro Cohen; Iwona Bil-Lula; Grzegorz Sawicki
Journal:  Proteome Sci       Date:  2020-04-20       Impact factor: 2.480

8.  Effects of Delayed Hypothermic Machine Perfusion on Kidney Grafts with a Preliminary Period of Static Cold Storage and a Total Cold Ischemia Time of Over 24 Hours.

Authors:  Gian Luigi Adani; Riccardo Pravisani; Sara Crestale; Umberto Baccarani; Cathryn A Scott; Lorenzo D'Alì; Giovanna DeMaglio; Patrizia Tulissi; Clotilde Vallone; Miriam Isola; Elda Righi; Stefano Pizzolito; Carla Di Loreto; Andrea Risaliti
Journal:  Ann Transplant       Date:  2020-02-25       Impact factor: 1.530

9.  Esophagectomy for Esophageal Cancer in a Patient with Protein C Deficiency: A Case Report.

Authors:  Naoto Ujiie; Yusuke Taniyama; Hiroshi Okamoto; Chiaki Sato; Kai Takaya; Toshiaki Fukutomi; Takashi Kamei
Journal:  Ann Thorac Cardiovasc Surg       Date:  2020-08-19       Impact factor: 1.520

10.  Controlled Oxygenated Rewarming Compensates for Cold Storage-induced Dysfunction in Kidney Grafts.

Authors:  Charlotte von Horn; Hristo Zlatev; Moritz Kaths; Andreas Paul; Thomas Minor
Journal:  Transplantation       Date:  2021-06-23       Impact factor: 5.385

  10 in total