Literature DB >> 29697255

Fluorescent Nanoprobes with Oriented Modified Antibodies to Improve Lateral Flow Immunoassay of Cardiac Troponin I.

Doudou Lou1, Lin Fan1, Yan Cui2, Yefei Zhu3, Ning Gu1, Yu Zhang1.   

Abstract

Performance of nanoprobes can often determine the detection level of Lateral immunochromatography. Traditional probes were limited by the quantity and orientation of antibodies, immune activity of the Fab region or binding strength between protein and substrate. This study developed a new efficient and robust technology to construct fluorescent nanoprobes with oriented modified antibodies, based on specific binding of the Fc region of antibody with streptococcal protein G (SPG) on the surface of polystyrene microspheres (MS) and subsequent covalent cross-linking at binding sites to firm them. Lateral flow immunoassay using these probes was applied for the detection of cardiac troponin I (cTnI). The significantly improved detection sensitivity demonstrated that antibody orientation on MS surfaces effectively enhanced immunological activities of probes compared with random immobilizing methods. Furthermore, performance evaluation results of lateral flow test strips met clinical requirements perfectly, including limit of detection (0.032 ng/mL), linearity ( R > 0.99), repeatability (CV < 10%), correlation ( R > 0.99), and heat aging stability. This research also employed heterophilic blocking reagent (HBR) to actively block redundant binding sites of SPG for the first time in order to eliminate false positive interferences, improving the sensitivity and precision of test results further.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29697255     DOI: 10.1021/acs.analchem.7b05410

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  One-step time-resolved fluorescence microsphere immunochromatographic test strip for quantitative and simultaneous detection of DON and ZEN.

Authors:  Jiadi Sun; Liangzhe Wang; Jingdong Shao; Diaodiao Yang; Xuran Fu; Xiulan Sun
Journal:  Anal Bioanal Chem       Date:  2021-08-24       Impact factor: 4.142

2.  A sandwich-type electrochemical immunosensor for CYFRA 21-1 based on probe-confined in PtPd/polydopamine/hollow carbon spheres coupled with dendritic Au@Rh nanocrystals.

Authors:  Yi-Ge Feng; Jia-Wen He; Di-Nan Chen; Lu-Yao Jiang; Ai-Jun Wang; Ning Bao; Jiu-Ju Feng
Journal:  Mikrochim Acta       Date:  2022-07-05       Impact factor: 6.408

3.  An amphiphilic-ligand-modified gold nanoflower probe for enhancing the stability of lateral flow immunoassays in dried distillers grains.

Authors:  Tongtong Ma; Hong Duan; Wenjing Zhang; Yanna Shao; Liangwen Hao; Xirui Chen; Yuankui Leng; Xiaolin Huang; Yonghua Xiong
Journal:  RSC Adv       Date:  2019-11-11       Impact factor: 4.036

4.  Fluorescence Based on Surface Plasmon Coupled Emission for Ultrahigh Sensitivity Immunoassay of Cardiac Troponin I.

Authors:  Vien Thi Tran; Heongkyu Ju
Journal:  Biomedicines       Date:  2021-04-21

5.  Highly Sensitive Lanthanide-Doped Nanoparticles-Based Point-of-Care Diagnosis of Human Cardiac Troponin I.

Authors:  Lu Chen; Shan-Yong Zhou; Wei Zhu; Sheng-Ping Liu; Jing-Xi Zhang; He Zhuang; Jing-Ling Zhang; Yong-Sheng Li; Fei Gao
Journal:  Int J Nanomedicine       Date:  2022-02-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.