| Literature DB >> 29693646 |
Tingsheng Lu1, Chunshan Luo1, Beiping Ouyang1, Qiling Chen1, Zhongliang Deng2.
Abstract
BACKGROUND This study aimed to investigate the association between range of motion of the cervical vertebrae and various C5/C6 intervertebral space distraction heights. MATERIAL AND METHODS The cervical vertebrae from 6 fresh adult human cadavers were used to prepare the models. Changes in C4/C5 and C6/C7 intervertebral disk pressures, articular process pressure, and range of motion of the cervical vertebrae before and after the distraction of the C5/C6 intervertebral space at benchmark heights of 100%, 120%, 140%, and 160% were tested under different exercise loads. RESULTS The pressure on the adjacent intervertebral disks was highest with the standing upright position before distraction, varied with different positions of the specimens and distraction heights after distraction, and was closest to that before distraction at a distraction height of 120% (P<0.05). The pressure of the adjacent articular processes was highest with left and right rotations before distraction, varied with different positions of the specimens and distraction heights after distraction, and was lowest under the same exercise load with different positions at a distraction height of 120% (P<0.05). The ranges of motion of the cervical vertebrae and intervertebral disks were largest without distraction and at a distraction height of 120% after distraction, respectively (P<0.05). CONCLUSIONS When removing the C5/C6 intervertebral disk and implanting an intervertebral bone graft, a benchmark height of 120% had little influence on the pressure of the adjacent intervertebral disks and articular processes and range of motion of the cervical vertebrae and is therefore an appropriate intervertebral space distraction height.Entities:
Mesh:
Year: 2018 PMID: 29693646 PMCID: PMC5939602 DOI: 10.12659/msm.909868
Source DB: PubMed Journal: Med Sci Monit ISSN: 1234-1010
Figure 1Pressures in the intervertebral disk (A) and articular process (B) tests.
Figure 2The test method for the range of motion of the cervical vertebrae under a 2.50-Nm force moment load.
Figure 3Methods of intervertebral bone graft (A) and intervertebral height measurements (B).
Comparison of values of intervertebral disc pressure of C4/5 and C6/7 intervertebral discs with different distraction heights and different directions under a 2.50 Nm force moment load (MPa).
| Open height | Group | Neutral position | Flexion 30° | Extension 30° | Left and right lateral bending 30° | Left and right lateral rotation 30° |
|---|---|---|---|---|---|---|
| Before distraction | C4/5 | 0.9434±0.0042 | 0.9217±0.0027 | 0.1261±0.0026 | 0.6157±0.0031 | 0.8432±0.0034 |
| C6/7 | 0.9156±0.0054 | 0.8367±0.0074 | 0.1083±0.0034 | 0.5224±0.0038 | 0.4124±0.0039 | |
| 100% | C4/5 | 0.9782±0.0045 | 1.0354±0.0028 | 0.1678±0.0018 | 0.7421±0.0025 | 0.8124±0.0024 |
| C6/7 | 1.0036±0.0024 | 0.9487±0.0034 | 0.1584±0.0034 | 0.7120±0.0034 | 0.4467±0.0038 | |
| 120% | C4/5 | 0.9609±0.0029 | 0.0812±0.0018 | 0.0704±0.0030 | 0.0710±0.0026 | 0.8467±0.0038 |
| C6/7 | 0.9184±0.0024 | 0.0818±0.0024 | 0.0420±0.0022 | 0.0513±0.0027 | 0.5038±0.0024 | |
| 140% | C4/5 | 1.0428±0.0026 | 0.0817±0.0024 | 0.0814±0.0028 | 0.1320±0.0026 | 0.8618±0.0022 |
| C6/7 | 1.0824±0.0028 | 0.0841±0.0026 | 0.0641±0.0028 | 0.1101±0.0021 | 0.4156±0.0023 | |
| 160% | C4/5 | 1.1001±0.0028 | 1.0348±0.0020 | 0.1896±0.0027 | 0.7218±0.0031 | 0.8240±0.0024 |
| C6/7 | 1.0628±0.0021 | 0.9546±0.0019 | 0.1868±0.0018 | 0.6898±0.0018 | 0.5180±0.0026 |
Figure 4Intervertebral disk pressures at C4/C5 (A) and C6/C7 (B) with different distraction heights and different directions under a 2.50-Nm force moment load (MPa).
Comparison of C4/5 and C6/7 facet joint pressures value of in 2.5 Nm loading phase when different open height and different direction (MPa).
| Open height | Group | Neutral position | Flexion | Extension | Left lateral bending | right lateral bending | Left lateral rotation | Right lateral rotation |
|---|---|---|---|---|---|---|---|---|
| Before distraction | C4/5 | 0.9710± 0.0051 | 0.5972± 0.0034 | 1.8014± 0.0043 | 1.4750± 0.0039 | 1.4666± 0.0035 | 1.6613± 0.0025 | 1.6592± 0.0037 |
| C6/7 | 0.9393± 0.0059 | 0.5689± 0.0072 | 1.6761± 0.0036 | 1.5132± 0.0047 | 1.5205± 0.0042 | 1.6294± 0.0018 | 1.6015± 0.0036 | |
| 100% | C4/5 | 0.9802± 0.0028 | 0.5810± 0.0031 | 1.8557± 0.0057 | 1.5011± 0.0074 | 1.5075± 0.0026 | 1.7008± 0.0030 | 1.6881± 0.0031 |
| C6/7 | 0.9441± 0.0039 | 0.5692± 0.0086 | 1.7643± 0.0049 | 1.5326± 0.0070 | 1.5298± 0.0031 | 1.6667± 0.0041 | 1.6708± 0.0028 | |
| 120% | C4/5 | 0.9775± 0.0035 | 0.5315± 0.0029 | 1.7559± 0.0022 | 1.3816± 0.0055 | 1.3821± 0.0048 | 1.5509± 0.0028 | 1.5635± 0.0024 |
| C6/7 | 0.9411± 0.0040 | 0.5660± 0.0046 | 1.6308± 0.0034 | 1.4453± 0.0035 | 1.4408± 0.0045 | 1.6045± 0.0022 | 1.6127± 0.0019 | |
| 140% | C4/5 | 1.0124± 0.0030 | 0.5301± 0.0039 | 1.7706± 0.0025 | 1.5254± 0.0028 | 1.5176± 0.0034 | 1.5991± 0.0026 | 1.5900± 0.0038 |
| C6/7 | 0.9605± 0.0027 | 0.5655± 0.0021 | 1.6478± 0.0033 | 1.5417± 0.0023 | 1.5403± 0.0029 | 1.6476± 0.0031 | 1.6471± 0.0022 | |
| 160% | C4/5 | 1.0402± 0.0035 | 0.5712± 0.0045 | 1.7699± 0.00238 | 1.6240± 0.0031 | 1.6273± 0.0035 | 1.6515± 0.0020 | 1.6602± 0.0034 |
| C6/7 | 0.9839± 0.0033 | 0.5598± 0.0050 | 1.6653± 0.0032 | 1.6127± 0.0029 | 1.6032± 0.0024 | 1.6546± 0.0033 | 1.6619± 0.0030 |
Figure 5C4/C5 (A) and C6/C7 (B) facet joint pressure values in the 2.5-Nm loading phase with different open heights and directions (MPa).
Comparison of cervical activity in 2.5 Nm load torque when different opening height.
| Before distraction | 100% | 120% | 140% | 160% | |
|---|---|---|---|---|---|
| Flexion | 58.26±7.14 | 43.55±8.61 | 45.90±6.59 | 41.83±7.25 | 40.27±7.82 |
| Extension | 61.04±6.92 | 48.81±7.73 | 52.65±7.03 | 48.76±7.39 | 48.05±7.11 |
| Lateral bending | 30.11±7.33 | 24.63±7.02 | 26.17±7.56 | 23.98±6.95 | 22.67±7.35 |