Literature DB >> 29692633

Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times.

Sanjay Prasad Gupta1, Basanta Kumar Shrestha1.   

Abstract

PURPOSE: To determine and compare the shear bond strength (SBS) of bracket-bonding system cured with light-emitting diode (LED) and halogen-based light-curing unit at various polymerization times.
MATERIALS AND METHODS: Ninety six human maxillary premolar teeth extracted for orthodontic purpose were divided into four groups, according to the light-curing unit and exposure times used. In the halogen group, the specimens were light cured for 20 and 40 seconds. In the LED group, the specimens were light cured for 5 and 10 seconds. Stainless steel brackets were bonded with Enlight bonding system, stored in distilled water at 37°C for 24 hours and then submitted to SBS testing in a universal testing machine at a crosshead speed of 0.5 mm/minute. Adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the teeth determined by stereomicroscope at 10× magnification.
RESULTS: The highest mean SBS was obtained with the halogen 40 seconds (18.27 MPa) followed by halogen 20 seconds (15.36 MPa), LED 10 seconds (14.60 MPa) and least with LED 5 seconds (12.49 MPa) group. According to analysis of variance (ANOVA) and Tukey's multiple-comparison test, SBS of halogen 20 seconds group was not significantly different from halogen 40 seconds group, LED 5 seconds group and LED 10 seconds group, whereas halogen 40 seconds group was significantly different from LED 5 seconds and LED 10 seconds group. The method of light curing did not influence the ARI, with score 2 being predominant.
CONCLUSION: Polymerization with both halogen and LED resulted in SBS values that were clinically acceptable for orthodontic treatment in all groups. Hence, for bonding orthodontic brackets, photoactivation with halogen for 20 seconds and LED for 5 seconds is suggested.

Entities:  

Keywords:  LED-curing light; halogen-curing light; polymerization time; shear bond strength

Year:  2018        PMID: 29692633      PMCID: PMC5901200          DOI: 10.2147/CCIDE.S155829

Source DB:  PubMed          Journal:  Clin Cosmet Investig Dent        ISSN: 1179-1357


  45 in total

1.  Orthodontic in vivo bond strength: comparison with in vitro results.

Authors:  K L Pickett; P L Sadowsky; A Jacobson; W Lacefield
Journal:  Angle Orthod       Date:  2001-04       Impact factor: 2.079

2.  Structural conformation of in vitro and in vivo aged orthodontic elastomeric modules.

Authors:  T Eliades; G Eliades; D C Watts
Journal:  Eur J Orthod       Date:  1999-12       Impact factor: 3.075

3.  A simple method of increasing the adhesion of acrylic filling materials to enamel surfaces.

Authors:  M G BUONOCORE
Journal:  J Dent Res       Date:  1955-12       Impact factor: 6.116

4.  Light-curing time reduction with a new high-power halogen lamp.

Authors:  Christine Bettina Staudt; Anestis Mavropoulos; Serge Bouillaguet; Stavros Kiliaridis; Ivo Krejci
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-12       Impact factor: 2.650

5.  Effect of a self-etching primer on shear bond strength of adhesive precoated brackets in vivo.

Authors:  Julio P Cal-Neto; José Augusto M Miguel; Eduardo Zanella
Journal:  Angle Orthod       Date:  2006-01       Impact factor: 2.079

6.  Direct bonding of orthodontic attachments to teeth: the relation of adhesive bond strength to gauze mesh size.

Authors:  I R Reynolds; J A von Fraunhofer
Journal:  Br J Orthod       Date:  1976-04

7.  A critique of bond strength testing in orthodontics.

Authors:  N A Fox; J F McCabe; J G Buckley
Journal:  Br J Orthod       Date:  1994-02

8.  Shear bond strength of composite to enamel and dentin using Scotchbond Multi-Purpose.

Authors:  W W Barkmeier; R L Erickson
Journal:  Am J Dent       Date:  1994-06       Impact factor: 1.522

9.  Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling.

Authors:  Erion Cerekja; Banu Cakirer
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

10.  Influence of different tooth types on the bond strength of two orthodontic adhesive systems.

Authors:  Bora Oztürk; Siddik Malkoç; Alp Erdin Koyutürk; Bülent Catalbas; Füsun Ozer
Journal:  Eur J Orthod       Date:  2008-08       Impact factor: 3.075

View more
  2 in total

1.  A Comparative Study on the Effect of Different Methods of Recycling Orthodontic Brackets on Shear Bond Strength.

Authors:  Purna Prasad Khanal; Basanta Kumar Shrestha; Rajiv Yadav; Sanjay Prasad Gupta
Journal:  Int J Dent       Date:  2021-01-21

2.  A Study on the Photopolymerization Kinetics of Selected Dental Resins Using Fourier Infrared Spectroscopy (FTIR).

Authors:  Mirosław Kwaśny; Jakub Polkowski; Aneta Bombalska
Journal:  Materials (Basel)       Date:  2022-08-25       Impact factor: 3.748

  2 in total