Literature DB >> 16360916

Light-curing time reduction with a new high-power halogen lamp.

Christine Bettina Staudt1, Anestis Mavropoulos, Serge Bouillaguet, Stavros Kiliaridis, Ivo Krejci.   

Abstract

INTRODUCTION: Orthodontic brackets are routinely bonded with light-cured adhesives. Conventional halogen lights used in bonding have the disadvantage of a long curing time, and the available alternatives (laser and plasma lights) are expensive. Our aim was to investigate the minimum time necessary to bond brackets with a new, relatively low-priced, high-power halogen light.
METHODS: Five groups of 15 deciduous bovine incisors were bonded with stainless steel brackets (Mini Diamond Twin, Ormco, Orange, Calif) by using different lamps and curing times. Three of the groups were bonded by using a high-power halogen light (Swiss Master Light, Electro Medical Systems, Nyon, Switzerland) for 2, 3, and 6 seconds, respectively. The fourth group, bonded with a fast halogen light (Optilux 501, Sybron Dental Specialties, Danbury, Conn) for 40 seconds, served as the positive control group. The fifth group, the comparison group, was bonded with a plasma light (Remecure, Remedent, Deurle, Belgium) for 4 seconds. After storage for 24 hours in the dark at 37 degrees C in water, shear bond strength was measured with a universal testing machine.
RESULTS: A curing time of 2 seconds with the high-power halogen light negatively affected the bond strength and the probability of bond survival. The adhesive remnant index scores were not significantly different among the groups. Most failures (> 60%) occurred at the bracket base/adhesive interface.
CONCLUSIONS: The high-power halogen light seems to be a cost-effective solution to reducing curing time. The recommended curing times to bond stainless steel brackets are 6 seconds and, with caution, even 3 seconds.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16360916     DOI: 10.1016/j.ajodo.2004.08.020

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Shear bond strength of different adhesives tested in accordance with DIN 13990-1/-2 and using various methods of enamel conditioning.

Authors:  C Richter; P-G Jost-Brinkmann
Journal:  J Orofac Orthop       Date:  2015-03       Impact factor: 1.938

2.  Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling.

Authors:  Erion Cerekja; Banu Cakirer
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

3.  Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times.

Authors:  Sanjay Prasad Gupta; Basanta Kumar Shrestha
Journal:  Clin Cosmet Investig Dent       Date:  2018-04-10
  3 in total