Literature DB >> 29691987

Accuracy of the match between cone beam computed tomography and model scan data in template-guided implant planning: A prospective controlled clinical study.

Sigmar Schnutenhaus1, Sebastian Gröller1, Ralph G Luthardt1, Heike Rudolph1.   

Abstract

BACKGROUND: Template-guided implant placement is a method for optimal implant positioning from a prosthetic and surgical viewpoint. The treatment planning is based on three-dimensional X-ray data and model scan data, as well as on prosthetic planning (set-up). These data are matched (superimposed) with the aid of an X-ray template or by manual matching without special referencing.
PURPOSE: The objective of this prospective controlled clinical study was to determine and compare the accuracy of the match with and without an additional X-ray template.
MATERIALS AND METHODS: The DICOM data of the cone beam computed tomography (CBCT) were converted into surface data sets and then superimposed on model scan data using three different methods (manually, based on an X-ray template, or semi-automatically with computer assistance). The mean deviations between these results of these matching methods were investigated.
RESULTS: The procedures achieved a matching accuracy of 0.2 mm on average. This corresponds to the resolution of the CBCT (0.2 voxels). Further studies are necessary to verify the procedure even for patients with few (0-4) residual teeth.
CONCLUSION: In the presence of a sufficient number of residual teeth, the manual matching of model scan data with CBCT data is sufficiently accurate for implant planning and template-guided implementation. The results of the present study suggest that X-ray templates can be dispensed with saving the patient a substantial amount of time and money.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D implant planning; CBCT; X-ray template; dental implants; drilling templates; model scan data; template-guided implantation

Mesh:

Substances:

Year:  2018        PMID: 29691987     DOI: 10.1111/cid.12614

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  7 in total

1.  [Research advances in the use of digital surgical guides in implantology].

Authors:  Xiao-Hua Wang; Ai-Peng Liu; Wen-Zheng Deng
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-02-01

2.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

3.  Accuracy of computer-assisted surgery in immediate implant placement: An experimental study.

Authors:  Nicole Báez-Marrero; José Luis Rafel; Yalil Augusto Rodríguez-Cárdenas; Aron Aliaga-Del Castillo; Heraldo Luis Dias-Da Silveira; Luis Ernesto Arriola-Guillén
Journal:  J Indian Soc Periodontol       Date:  2021-09-27

4.  Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial.

Authors:  Cornelia Edelmann; Martin Wetzel; Anne Knipper; Ralph G Luthardt; Sigmar Schnutenhaus
Journal:  J Clin Med       Date:  2021-04-21       Impact factor: 4.241

5.  Alveolar ridge preservation and primary stability as influencing factors on the transfer accuracy of static guided implant placement: a prospective clinical trial.

Authors:  Sigmar Schnutenhaus; Liesa Brunken; Cornelia Edelmann; Jens Dreyhaupt; Heike Rudolph; Ralph G Luthardt
Journal:  BMC Oral Health       Date:  2020-06-29       Impact factor: 2.757

6.  Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry.

Authors:  Akira Komuro; Yoichi Yamada; Satoshi Uesugi; Hiroaki Terashima; Masashi Kimura; Hiroto Kishimoto; Tsutomu Iida; Katsuya Sakamoto; Kenichi Okuda; Kaoru Kusano; Shunsuke Baba; Takashi Sakamoto
Journal:  Int J Implant Dent       Date:  2021-06-30

7.  Fully Digital Workflow for Planning Static Guided Implant Surgery: A Prospective Accuracy Study.

Authors:  Chia-Cheng Lin; Ching-Zong Wu; Mao-Suan Huang; Chiung-Fang Huang; Hsin-Chung Cheng; Dayen Peter Wang
Journal:  J Clin Med       Date:  2020-04-01       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.