Literature DB >> 29684571

Cryoballoon Best Practices II: Practical guide to procedural monitoring and dosing during atrial fibrillation ablation from the perspective of experienced users.

Wilber Su1, Arash Aryana2, Rod Passman3, Gurjit Singh4, Robert Hokanson5, Marcin Kowalski6, Jason Andrade7, Paul Wang8.   

Abstract

Since the evaluation of the cryoballoon in the Sustained Treatment Of Paroxysmal Atrial Fibrillation trial, more than 350,000 patients with atrial fibrillation have been treated. Several studies have reported improved outcomes using the second-generation cryoballoon, and recent publications have evaluated modifications, refinements, and improvements in procedural techniques. Here, peer-reviewed articles published since the first cryoballoon best practices review were summarized against the technical practices of physicians with a high level of experience with the cryoballoon (average ≥6 years of experience in ≥900 cases). This summary includes a comprehensive literature review along with practical usage guidance from physicians using the cryoballoon to facilitate safe, efficient, and effective outcomes for patients with atrial fibrillation.
Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Atrial fibrillation; Best practice; Catheter ablation; Cryoablation; Cryoballoon

Mesh:

Year:  2018        PMID: 29684571     DOI: 10.1016/j.hrthm.2018.04.021

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  15 in total

1.  Patient characteristics as predictors of recurrence of atrial fibrillation following cryoballoon ablation.

Authors:  Aakash A Bavishi; Rachel M Kaplan; Graham Peigh; Celso L Diaz; Jayson R Baman; Amar Trivedi; Jeremiah Wasserlauf; Mark J Shen; Prasongchai Sattayaprasert; Alexandru B Chicos; Susan Kim; Nishant Verma; Rishi Arora; Albert Lin; Bradley P Knight; Rod S Passman
Journal:  Pacing Clin Electrophysiol       Date:  2019-04-09       Impact factor: 1.976

2.  Catheter ablation for atrial fibrillation in a low-volume center using contemporary technology.

Authors:  Julian Cheong Kiat Tay; Xinzhe James Cai; Jing Lin; Shufen Liang; Ai Ling Him; Sherida Binte Syed Hamid; Kelvin Cheok Keng Wong; Colin Yeo; Vern Hsen Tan
Journal:  Int J Cardiol Heart Vasc       Date:  2020-10-23

3.  Novel three-dimensional imaging approach for cryoballoon navigation and confirmation of pulmonary vein occlusion.

Authors:  Christopher A B Kowalewski; Miguel Rodrigo; Chad Brodt; Francois Haddad; Paul J Wang; Sanjiv M Narayan
Journal:  Pacing Clin Electrophysiol       Date:  2020-02-17       Impact factor: 1.976

4.  Minimal dose of cryoballoon ablation leading to atrioesophageal fistula formation.

Authors:  Wilber Su; Qinling Zhang; William Reichert; Zeshan Ahmad; Emrie Tomaiko; Xi Su
Journal:  HeartRhythm Case Rep       Date:  2020-12-05

Review 5.  The FIRE AND ICE Trial: What We Know, What We Can Still Learn, and What We Need to Address in the Future.

Authors:  Karl-Heinz Kuck; Josep Brugada; Michael Schlüter; Kendra M Braegelmann; Fred J Kueffer; K R Julian Chun; Jean-Paul Albenque; Claudio Tondo; Hugh Calkins
Journal:  J Am Heart Assoc       Date:  2018-12-18       Impact factor: 5.501

6.  Safety and efficacy of cryoballoon ablation for the treatment of paroxysmal and persistent AF in a real-world global setting: Results from the Cryo AF Global Registry.

Authors:  Kyoung Ryul Julian Chun; Ken Okumura; Fernando Scazzuso; Young Keun On; Fred J Kueffer; Kendra M Braegelmann; Surinder Kaur Khelae; Fawzia Al-Kandari; Csaba Földesi
Journal:  J Arrhythm       Date:  2021-01-25

7.  Acute safety, efficacy, and advantages of a novel cryoballoon ablation system for pulmonary vein isolation in patients with paroxysmal atrial fibrillation: initial clinical experience.

Authors:  Ante Anic; Nigel Lever; Andrew Martin; Toni Breskovic; Matthew S Sulkin; Elizabeth Duffy; Walid I Saliba; Mark J Niebauer; Oussama M Wazni; Niraj Varma
Journal:  Europace       Date:  2021-03-17       Impact factor: 5.214

8.  Cryoballoon-to-Pulmonary Vein Occlusion Assessment via Capnography Technique: Where Does Occlusion Testing by End-Tidal CO2 Measurement "Fit" as a Predictor of Long-Term Efficacy?

Authors:  Robert A Pickett; Kimberly Owens; Penny Landis; Rahmani Sara; Hae W Lim
Journal:  J Atr Fibrillation       Date:  2018-06-30

9.  Risk of atrioesophageal fistula with cryoballoon ablation of atrial fibrillation.

Authors:  Jonathan P Piccini; Kendra M Braegelmann; Sara Simma; Jayanthi N Koneru; Kenneth A Ellenbogen
Journal:  Heart Rhythm O2       Date:  2020-05-28

10.  Relationship between time-to-isolation and freeze duration: Computational modeling of dosing for Arctic Front Advance and Arctic Front Advance Pro cryoballoons.

Authors:  Michael K Getman; Erik Wissner; Ravi Ranjan; Jean-Pierre Lalonde
Journal:  J Cardiovasc Electrophysiol       Date:  2019-09-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.