Abstract

Animal studies have suggested that 99mTc-mercapto-acetylglycyl-glycyl-glycine (99mTc-MAG3) might be suitable for the determination of the renal plasma flow (RPF) because of its high renal clearance. In this study 131I-orthoiodohippurate (131I-OIH) and 99mTc-MAG3 (labeling always greater than 95%) were administered simultaneously in 11 patients (creatinine clearance ranging from 14 to 130 ml/min per 1.73 m2) to measure effective RPF(ERPF) using the standard technique (UV/P). Glomerular filtration rate (GFR; clearance of 125I-thalamate, 125I-OT) was also measured. The mean ratio of 99mTc-MAG3 clearance to 131I-IOH clearance was 0.55 +/- 0.02 (SEM), P less than 0.01, n = 16, and was independent of GFR and ERPF. To study this difference in renal handling of the radiopharmaceuticals, renal extractions by the right kidney were determined in another six patients after a single shot of the agents. Renal extraction of 99mTc-MAG3 was 0.60 +/- 0.03 after 5 min, and 0.41 +/- 0.08 after 30 min. Renal extraction of 131I-OIH amounted to 0.86 +/- 0.04 and 0.77 +/- 0.03, respectively. Using renal extractions of 0.41 and 0.77, respectively, it appeared that calculated renal plasma flows measured simultaneously with 99mTc-MAG3 and 131I-OIH were similar. Protein binding 30 min after the priming dose was 66% for 99mTc-MAG3 and 47% for 123I-OIH. We conclude that in spite of a high renal clearance (ratio to 125I-OT clearance 2.69 +/- 0.27), 99mTc-MAG3 seems unsuitable for an accurate determination of the RPF.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2968259     DOI: 10.1007/bf00252614

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  6 in total

1.  A radioisotope method for simultaneous determination of the glomerular filtration rate and the effective renal plasma flow.

Authors:  A J Donker; G K van der Hem; W J Sluiter; H Beekhuis
Journal:  Neth J Med       Date:  1977       Impact factor: 1.422

2.  Pediatric renal iodine-123 orthoiodohippurate dosimetry.

Authors:  C S Marcus; J H Kuperus
Journal:  J Nucl Med       Date:  1985-10       Impact factor: 10.057

3.  Renal clearance and extraction parameters of ortho-iodohippurate (I-123) compared with OIH(I-131) and PAH.

Authors:  R C Stadalnik; J M Vogel; A L Jansholt; K A Krohn; N M Matolo; M C Lagunas-Solar; F W Zielinski
Journal:  J Nucl Med       Date:  1980-02       Impact factor: 10.057

4.  Synthesis and biological evaluation of technetium-99m MAG3 as a hippuran replacement.

Authors:  A R Fritzberg; S Kasina; D Eshima; D L Johnson
Journal:  J Nucl Med       Date:  1986-01       Impact factor: 10.057

5.  Comparison of renal extraction efficiencies for radioactive agents in the normal dog.

Authors:  J G McAfee; Z D Grossman; G Gagne; A L Zens; G Subramanian; F D Thomas; P Fernandez; M L Roskopf
Journal:  J Nucl Med       Date:  1981-04       Impact factor: 10.057

6.  Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers.

Authors:  A Taylor; D Eshima; A R Fritzberg; P E Christian; S Kasina
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

  6 in total
  7 in total

1.  SNMMI Procedure Standard/EANM Practice Guideline for Diuretic Renal Scintigraphy in Adults With Suspected Upper Urinary Tract Obstruction 1.0.

Authors:  Andrew T Taylor; David C Brandon; Diego de Palma; M Donald Blaufox; Emmanuel Durand; Belkis Erbas; Sandra F Grant; Andrew J W Hilson; Anni Morsing
Journal:  Semin Nucl Med       Date:  2018-03-16       Impact factor: 4.446

2.  Dynamic renal scanning using 99mTc-MAG-3 in man.

Authors:  C L Maini; P Antonacci; A Sargiotto; G Castellano; V Podio
Journal:  Eur J Nucl Med       Date:  1989

3.  (99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.

Authors:  Andrew T Taylor; Malgorzata Lipowska; Luigi G Marzilli
Journal:  J Nucl Med       Date:  2010-02-11       Impact factor: 10.057

4.  Assessment of Individual Renal Function Using 99mTc-MAG3 Renography.

Authors:  Hyeong-Joon Lim; Seok Hwa Choi
Journal:  In Vivo       Date:  2022 Jan-Feb       Impact factor: 2.155

Review 5.  Radionuclides in nephrourology, part 1: Radiopharmaceuticals, quality control, and quantitative indices.

Authors:  Andrew T Taylor
Journal:  J Nucl Med       Date:  2014-02-18       Impact factor: 10.057

6.  First experience in healthy volunteers with technetium-99m L,L-ethylenedicysteine, a new renal imaging agent.

Authors:  C G Van Nerom; G M Bormans; M J De Roo; A M Verbruggen
Journal:  Eur J Nucl Med       Date:  1993-09

7.  Renal and extrarenal clearance of 99mTc-MAG3: a comparison with 125I-OIH and 51Cr-EDTA in patients representing all levels of glomerular filtration rate.

Authors:  M Rehling; B V Nielsen; E B Pedersen; L E Nielsen; H E Hansen; T Bacher
Journal:  Eur J Nucl Med       Date:  1995-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.