Literature DB >> 2940350

Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers.

A Taylor, D Eshima, A R Fritzberg, P E Christian, S Kasina.   

Abstract

Animal studies have suggested that the nonisomeric N3S triamide mercaptide ligand, 99mTc mercaptoacetyltriglycine (MAG3), may provide a satisfactory 99mTc-labeled replacement for 131I hippurate (OIH). Sequential 30-min [99mTc]MAG3 (5-10 mCi) and [131I]OIH (300 microCi) imaging studies were performed in ten normal volunteers in order to compare the image quality, renal excretion, blood clearance, and time to peak height of the renogram curve. In addition, [99mTc] MAG3 (5 mCi) and [131I]OIH (150 microCi) were administered simultaneously in eight volunteers for comparison of 180-min blood and plasma clearances and urine excretion. In the sequential imaging studies, the blood clearance of [99mTc]MAG3 was more rapid than [131I]OIH with a mean clearance of 1.30 l/min compared with 0.88 l/min for [131I]OIH (p less than 0.05). Seventy-three percent of the injected dose of the MAG3 was excreted by 30 min compared with 66.8% for [131I]OIH. Whole kidney and cortical renogram curves showed no significant difference in the time to peak height for MAG3 and [131I]OIH. In all subjects, the quality of the [99mTc]MAG3 images were clearly superior to [131I]OIH. Following simultaneous injection, blood and plasma clearances for [131I]OIH were more rapid than MAG3 when determined for multiple time intervals from 0-30 to 0-180 min (p less than or equal to 0.05). The 0-30-min clearances of MAG3 and [131I]OIH were only slightly greater than the 0-180-min clearances and can be used to obtain valid comparisons of the two agents. As in the sequential study, 30-min urine excretion was greater for MAG3 than [131I]OIH (73.1 compared with 69.6%) but the difference was not statistically significant. Although the differences in the MAG3 clearances following sequential and simultaneous administration are not satisfactorily explained, the fact that both clearances were rapid, the MAG3 and OIH renogram curves were quite similar, and 30-min urine excretions of MAG3 and OIH were essentially identical suggests that MAG3 may become a 99mTc replacement for [13I]OIH and further clinical evaluation is warranted.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 2940350

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  23 in total

Review 1.  Quantification of renal haemodynamics with radionuclides.

Authors:  A M Peters
Journal:  Eur J Nucl Med       Date:  1991

2.  Re(CO)3([18F]FEDA), a novel 18F PET renal tracer: Radiosynthesis and preclinical evaluation.

Authors:  Malgorzata Lipowska; Nashwa Jarkas; Ronald J Voll; Jonathon A Nye; Jeffrey Klenc; Mark M Goodman; Andrew T Taylor
Journal:  Nucl Med Biol       Date:  2017-12-27       Impact factor: 2.408

3.  99mTc-MAG3: dynamic studies in patients with renal disease.

Authors:  G H Schaap; T H Alferink; R B de Jong; P L Oe; J C Roos; A J Donker
Journal:  Eur J Nucl Med       Date:  1988

Review 4.  Clearance Pathways and Tumor Targeting of Imaging Nanoparticles.

Authors:  Mengxiao Yu; Jie Zheng
Journal:  ACS Nano       Date:  2015-07-14       Impact factor: 15.881

5.  99mTc(CO)3(NTA) and 131I-OIH: comparable plasma clearances in patients with chronic kidney disease.

Authors:  Andrew T Taylor; Malgorzata Lipowska; Hui Cai
Journal:  J Nucl Med       Date:  2013-02-19       Impact factor: 10.057

Review 6.  Radionuclides in nephrourology, part 1: Radiopharmaceuticals, quality control, and quantitative indices.

Authors:  Andrew T Taylor
Journal:  J Nucl Med       Date:  2014-02-18       Impact factor: 10.057

7.  Diagnostic significance of semiquantitative and quantitative parameters of Tc99m-Ethylenedicystine renal allograft scintigraphy.

Authors:  Sukanta Barai; Rakesh Kumar; Sada Nand Mehta; Amit Kumar Dinda; Rajiv Yadav; Guru Pada Bandopadhayaya; Singhal Tarun; Arun Malhotra
Journal:  Int Urol Nephrol       Date:  2003       Impact factor: 2.370

8.  Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers.

Authors:  Malgorzata Lipowska; Jeffrey Klenc; Russell D Folks; Andrew T Taylor
Journal:  Nucl Med Mol Imaging       Date:  2014-05-27

9.  Evaluation of the renal excretion characteristics of technetium-99m mercaptoacetylglycyl-D-alanylglycine in healthy volunteers.

Authors:  G M Bormans; B J Cleynhen; M J De Roo; A M Verbruggen
Journal:  Eur J Nucl Med       Date:  1992

10.  99mTc(CO)3-nitrilotriacetic acid: a new renal radiopharmaceutical showing pharmacokinetic properties in rats comparable to those of 131I-OIH.

Authors:  Malgorzata Lipowska; Luigi G Marzilli; Andrew T Taylor
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.