Literature DB >> 29681773

Accuracy evaluation of distance inverse square law in determining virtual electron source location in Siemens Primus linac.

Hamid Shafaei Douk1, Mahmoud Reza Aghamiri1, Mahdi Ghorbani2, Bagher Farhood3, Mohsen Bakhshandeh4, Hamid Reza Hemmati1.   

Abstract

AIM: The aim of this study is to evaluate the accuracy of the inverse square law (ISL) method for determining location of virtual electron source (SVir) in Siemens Primus linac.
BACKGROUND: So far, different experimental methods have presented for determining virtual and effective electron source location such as Full Width at Half Maximum (FWHM), Multiple Coulomb Scattering (MCS), and Multi Pinhole Camera (MPC) and Inverse Square Law (ISL) methods. Among these methods, Inverse Square Law is the most common used method.
MATERIALS AND METHODS: Firstly, Siemens Primus linac was simulated using MCNPX Monte Carlo code. Then, by using dose profiles obtained from the Monte Carlo simulations, the location of SVir was calculated for 5, 7, 8, 10, 12 and 14 MeV electron energies and 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm and 25 cm × 25 cm field sizes. Additionally, the location of SVir was obtained by the ISL method for the mentioned electron energies and field sizes. Finally, the values obtained by the ISL method were compared to the values resulted from Monte Carlo simulation.
RESULTS: The findings indicate that the calculated SVir values depend on beam energy and field size. For a specific energy, with increase of field size, the distance of SVir increases for most cases. Furthermore, for a special applicator, with increase of electron energy, the distance of SVir increases for most cases. The variation of SVir values versus change of field size in a certain energy is more than the variation of SVir values versus change of electron energy in a certain field size.
CONCLUSION: According to the results, it is concluded that the ISL method can be considered as a good method for calculation of SVir location in higher electron energies (14 MeV).

Entities:  

Keywords:  Electron energy; Field size; Inverse square law; Monte Carlo simulation; Virtual electron source

Year:  2018        PMID: 29681773      PMCID: PMC5908270          DOI: 10.1016/j.rpor.2018.01.002

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  6 in total

1.  A study on virtual source position for electron beams from a Mevatron MD linear accelerator.

Authors:  B P Ravindran
Journal:  Phys Med Biol       Date:  1999-05       Impact factor: 3.609

2.  Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator.

Authors:  D Rajasekar; N R Datta; K J Maria Das; S Ayyagari
Journal:  Phys Med Biol       Date:  2002-09-21       Impact factor: 3.609

3.  Determination of the source position for the electron beams from a high-energy linear accelerator.

Authors:  A Jamshidi; F T Kuchnir; C S Reft
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

4.  Demonstration of relatively new electron dosimetry measurement techniques on the Mevatron 80.

Authors:  J A Meyer; J R Palta; K R Hogstrom
Journal:  Med Phys       Date:  1984 Sep-Oct       Impact factor: 4.071

5.  Determination of the virtual electron source of a betatron.

Authors:  P Schröder-Babo
Journal:  Acta Radiol Suppl       Date:  1983

6.  Effect of air space and depth dose in electron beam therapy.

Authors:  F M Khan; W Sewchand; S H Levitt
Journal:  Radiology       Date:  1978-01       Impact factor: 11.105

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.