Literature DB >> 12375822

Electron beam therapy at extended SSDs: an analysis of output correction factors for a Mitsubishi linear accelerator.

D Rajasekar1, N R Datta, K J Maria Das, S Ayyagari.   

Abstract

The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies--6, 9, 12, 15 and 20 MeV-and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5 x 5 to 15 x 15 cm2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by evaluating correlation coefficients between the calculated and the measured values. The correlation coefficient was best with the linear-quadratic equation followed by the effective SSD method and the virtual source method. The output correction based on the linear-quadratic equation showed the best estimate of electron beam output at extended SSDs with an accuracy well within +/- 1%. The rapid reduction of dose due to the applicator-scattered component at d(max) point with an extended SSD was significant for the 5 x 5 cm2 applicator and lower energies.

Entities:  

Mesh:

Year:  2002        PMID: 12375822     DOI: 10.1088/0031-9155/47/18/303

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  Accuracy evaluation of distance inverse square law in determining virtual electron source location in Siemens Primus linac.

Authors:  Hamid Shafaei Douk; Mahmoud Reza Aghamiri; Mahdi Ghorbani; Bagher Farhood; Mohsen Bakhshandeh; Hamid Reza Hemmati
Journal:  Rep Pract Oncol Radiother       Date:  2018-02-19

2.  Electron beam therapy at extended source-to-surface distance: a Monte Carlo investigation.

Authors:  Tuathan P O'Shea; Mark J Foley; David Rajasekar; Patrick A Downes; Wil van der Putten; Margaret Moore; Andrew Shearer
Journal:  J Appl Clin Med Phys       Date:  2008-10-24       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.