Literature DB >> 29674072

Extended internal standard method for quantitative 1H NMR assisted by chromatography (EIC) for analyte overlapping impurity on 1H NMR spectra.

Naoki Saito1, Yuko Kitamaki2, Satoko Otsuka2, Noriko Yamanaka2, Yuzo Nishizaki3, Naoki Sugimoto3, Hisanori Imura4, Toshihide Ihara2.   

Abstract

We devised a novel extended internal standard method of quantitative 1H NMR (qNMR) assisted by chromatography (EIC) that accurately quantifies 1H signal areas of analytes, even when the chemical shifts of the impurity and analyte signals overlap completely. When impurity and analyte signals overlap in the 1H NMR spectrum but can be separated in a chromatogram, the response ratio of the impurity and an internal standard (IS) can be obtained from the chromatogram. If the response ratio can be converted into the 1H signal area ratio of the impurity and the IS, the 1H signal area of the analyte can be evaluated accurately by mathematically correcting the contributions of the 1H signal area of the impurity overlapping the analyte in the 1H NMR spectrum. In this study, gas chromatography and liquid chromatography were used. We used 2-chlorophenol and 4-chlorophenol containing phenol as an impurity as examples in which impurity and analyte signals overlap to validate and demonstrate the EIC, respectively. Because the 1H signals of 2-chlorophenol and phenol can be separated in specific alkaline solutions, 2-chlorophenol is suitable to validate the EIC by comparing analytical value obtained by the EIC with that by only qNMR under the alkaline condition. By the EIC, the purity of 2-chlorophenol was obtained with a relative expanded uncertainty (k = 2) of 0.24%. The purity matched that obtained under the alkaline condition. Furthermore, the EIC was also validated by evaluating the phenol content with the absolute calibration curve method by gas chromatography. Finally, we demonstrated that the EIC was possible to evaluate the purity of 4-chlorophenol, with a relative expanded uncertainty (k = 2) of 0.22%, which was not able to be separated from the 1H signal of phenol under any condition.
Copyright © 2018 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Analyte Overlapping impurity; Chlorophenol; Chromatography; EIC; Phenol; Quantitative (1)H NMR

Year:  2018        PMID: 29674072     DOI: 10.1016/j.talanta.2018.03.003

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Determination of perillaldehyde in perilla herbs using relative molar sensitivity to single-reference diphenyl sulfone.

Authors:  Naoko Masumoto; Yuzo Nishizaki; Takeshi Maruyama; Yasushi Igarashi; Kaori Nakajima; Taichi Yamazaki; Miho Kuroe; Masahiko Numata; Toshihide Ihara; Naoki Sugimoto; Kyoko Sato
Journal:  J Nat Med       Date:  2019-04-23       Impact factor: 2.343

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.